From various other studies, it is known that the maximum carbon dioxide concentration in different countries is between 1,000 ppm up to 1,500 ppm. Therefore, the research is focused on indoor environment, namely the production of pollutants from the persons inside office rooms. The article presents the trend of the carbon dioxide concentration from the occupants inside an office. It is examined the carbon dioxide production separately for men and women, for persons of different mass and for persons of different ages. It is also analyzed the carbon dioxide production during a sedentary and physical activities. In parallel with the production of carbon dioxide is presented the monitoring of the human pulse and blood pressure. All these parameters are monitored together with relative humidity and indoor air temperature. The aims of this paper is to describe the partial results of human respiration impact on indoor air quality in closed spaces and to research the connection between carbon dioxide concentration and human health.
Realization and exploitation of buildings involves in European Union about 40% of total energy consumption [1]. One of the elements of rationalization of energy consumption in buildings are the undertakings related with thermal modernization of buildings. The actions related with reducing the energy intensity of buildings are not always correlated with improvement of microclimate conditions in the rooms. Errors in the implementation of the energy efficiency program led to the phenomenon of sick building syndrome. The paper presents the results of the research conducted in a few educational buildings before and after thermal modernization. The research includes energy consumption for the heating of building and selected parameters of the interior microclimate. This analysis was carried out to evaluate the influence of energy saving activities on microclimate interior conditions. It was found that in many cases commonly used gravitational ventilation is not able to ensure the proper conditions of the interior microclimate, and the concentrations of carbon dioxide recorded in the tested rooms exceeded the applicable standards.
20 December 2017 in Chemistry & Chemical Technology
The background of this article is the potential energy savings of solar heat supply systems due to the use of the renewable energy of solar radiation. The motivation is to create a solar collector design that would combine the functions of both a building cover and a solar collector. It is necessary to investigate and compare different types of solar collector coatings (traditional and modern) and pipe diameters. The purpose of the article is to solve aspects of energy efficiency for new eco-friendly solar collectors. The most effective result occurred with the solar collector covered with the rubber–graphite composition of Grafplast PDA, and when using Prandelli/Tuborama pipes with a diameter of 0.016 m. Their efficiency increased by 8% compared to the second version of the collector made using a more traditional solution. The influence of the distance between the pipes and the flow rate of the heat carrier on the efficiency of the solar collectors was evaluated.
1 January 2021 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Purpose. To increase the energy and economic efficiency of heating coal mines with infrared heaters through energy saving measures, taking into account the dynamics of the discount rate. To achieve this goal, the task was to conduct an energy audit of the heating system of the mine during its reconstruction according to an improved method, taking into account the dynamics of the discount rate and measures that are not feasible at the same time. Methodology. When using infrared heating systems, local heating of the working area is provided. As a result, the necessary temperature conditions in the mines are maintained and there is a possibility of creating a local microclimate. A multifactorial experiment was performed and the research results were graphically and analytically described. Furthermore, the method of energy audit, taking into account the effect of complex interaction of factors and the dynamics of the degree of discount, is applied. Findings. According to the results of the experiment, a nomogram of the temperature regime of the irradiation area with an infrared heater was constructed, which was approximated by the analytical dependence. The optimal profit from the introduction of energy-saving technologies during operation is EUR 379.2 under the following conditions: replacement of the heating system from stationary to variable with automation; installation of a different number of infrared heaters NL-12R with power Q 1200 W each; application of the effect of complex interaction of factors. Originality. The conducted energy audit of the radiant heating system with the use of infrared heaters during the underground reconstruction showed that non-stationary heating is efficient because it saves energy and has the lowest payback period. Practical value. The expediency of using infrared heaters in variable mode in both energy and technical and economic aspects has been proved. These measures will provide comfortable conditions in the mine and have a significant economic effect.
1 November 2018 in IOP Conference Series: Materials Science and Engineering
At present, administrative buildings consume more energy than in the past, and they also contribute to environmental pollution. It is an effort to build buildings with minimal energy consumption. The energy consumed to operate the ventilation air is not insignificant. Techniques and control systems allow different ways of saving energy. However, all the savings measures should also take into account the quality of the internal environment for the health of people. This article compares a ventilation system with a constant flow of ventilating air with an air-conditioning system with varying air flow rates ensuring the required air quality.