Kyunam Rhee

Prof. Kyunam Rhee

Pukyong National University

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Building and Environment
Verified
Journal Article
Closed access
MSMi Su Shin
Mi Su Shin
Kyunam RheeKyunam Rhee
Kyunam Rhee
SPSang Hoon Park
Sang Hoon Park
MYMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim

9 January 2022 in Buildings
Verified
Journal Article
Open access
PDF file
XZXinwen Zhang
Xinwen Zhang
GJGun-Joo Jung
Gun-Joo Jung
Kyunam RheeKyunam Rhee
Kyunam Rhee
Most apartment buildings in South Korea use internal insulation systems to reduce building energy demand. However, thermal bridges such as balcony slabs in apartment buildings still lead to significant heat loss in winter, because the internal insulation system is not continuous in the balcony slab structure, and floor heating systems are commonly used in residential buildings. Therefore, this study investigates two types of thermal break elements, namely thermal break (TB) and thermal break-fiber glass reinforced polymer (TB-GFRP), to improve the thermal resistance of a balcony thermal bridge. To understand the effects of balcony thermal bridges with and without thermal break elements, the linear thermal transmittances of different balcony thermal bridges were analyzed using Physibel simulations. Then, the heating demand of a model apartment under varying thermal bridge conditions was evaluated using TRNSYS simulations. To understand the effect of insulation systems on heat loss through a balcony thermal bridge, apartments with internal and external insulation systems were studied. Whether the apartment was heating was also considered in the thermal transmittance analysis. Thus, the linear thermal transmittance of the thermal bridges with thermal break elements was reduced by more than 60%, and the heating energy demands were reduced by more than 8%.

22 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
MSMi-Su Shin
Mi-Su Shin
JCJi-Su Choi
Ji-Su Choi
Kyunam RheeKyunam Rhee
Kyunam Rhee
Ceiling radiant cooling panel (CRCP) systems are being increasingly applied to commercial buildings due to their high thermal comfort level and energy efficiency. It is recommended that CRCP systems should be operated at a relatively high chilled water temperature to prevent condensation and save energy. However, even though a high chilled water temperature is effective for achieving condensation-free operation and high chiller efficiency, it can lead to insufficient cooling capacity. In this study, a method of enhancing the cooling capacity of CRCP systems was investigated through mock-up chamber tests. The open-type installation of CRCPs and the combination of air circulators were used to enhance the cooling capacity and energy performance of CRCP systems. Experimental results showed that compared to a conventional CRCP system, the cooling capacity of an open-type CRCP system with air circulators increased by up to 26.2%, and its cooling energy consumption decreased by up to 26.4%. Additionally, the open-type CRCP system with air circulators reduced the difference between the room air temperature and mean chilled water temperature. Thus, the proposed system can operate at a relatively high chilled water temperature, which is effective for reducing condensation risk and cooling energy consumption.

9 November 2024 in Energy and Buildings
Verified
Journal Article
Closed access
XZXinwen Zhang
Xinwen Zhang
Kyunam RheeKyunam Rhee
Kyunam Rhee
GJGun-Joo Jung
Gun-Joo Jung
Chul KimChul Kim
Chul Kim

1 July 2021 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Kyunam RheeKyunam Rhee
Kyunam Rhee
SCSun-Ho Choi
Sun-Ho Choi
ATAgisilaos Tsouvalas
Agisilaos Tsouvalas

18 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
MSMi-Su Shin
Mi-Su Shin
Kyunam RheeKyunam Rhee
Kyunam Rhee
JYJi-Yong Yu
Ji-Yong Yu
GJGun-Joo Jung
Gun-Joo Jung
This study investigated the impact of thermally improved spacers (TISs) on the condensation prevention and energy saving performances of residential windows. The temperature factor and total U-value were analyzed with the two-box model, by which the TISs are represented with the equivalent thermal conductivity. The results showed that the TISs could increase the temperature factor by up to 12%, and this significantly improved the condensation prevention performance. In addition, it was proved that the TIS enables the prevention of the condensation at an outdoor temperature that is 4.2 °C to 15.7 °C lower compared with the conventional spacer. Also, it was shown that the TISs reduce the total U-value by an amount from 0.07 W/m2K to 0.12 W/m2K, implying that the heat loss through the window is reduced by a rate from 2.8% to 8.2%. In addition, the results of the whole building energy simulation proved that the TISs can reduce the annual heating-energy consumption by a rate from 3.0% to 6.3%. The results were then used for the development of monographs to determine the equivalent thermal conductivity of a window spacer that can meet the performance criteria in terms of condensation prevention and energy saving.