The behavior of center columns in shallow-buried underground subway station structures resembles that of high-rise buildings. In both cases, these columns experience significant vertical loads during earthquake events and are susceptible to brittle failure due to inadequate deformation capacity. In this study, the design concept of split columns, commonly employed in high-rise structures, is adapted for application in a two-story, two-span subway station. Initially, a comparative analysis was conducted using quasi-static pushover analysis to assess the horizontal deformation characteristics of traditional and split columns under high axial loads. Subsequently, a comprehensive quasi-static pushover analysis model encompassing the soil–structure interaction was formulated. This model was employed to investigate differences in seismic performance between traditional and innovative underground structures, considering internal forces, deformation capacity, and plastic damage of crucial elements. The analysis results demonstrate that the incorporation of split columns in a two-story, two-span subway station enhances the overall seismic performance of the structure. This enhancement arises from the fact that split columns mitigate excessive shear forces while effectively utilizing their vertical support and horizontal deformation capacities.
Numerical analysis is an important method for the study of seismic performance of underground structures. Current research on the seismic damage of Daikai station and the subway tunnel during the Great Hanshin earthquake mainly focuses on the dynamic time-history analysis. However, the modeling process of the dynamic time-history analysis is complicated and shows the characteristics of the enormous calculation amount, long running time and low computation efficiency. This paper briefly introduces the seismic phenomena of Daikai station and the subway tunnel during the Great Hanshin earthquake. The internal forces of Daikai station and the subway tunnel under horizontal and vertical bi-directional seismic effects are obtained by simplified seismic analysis. The pushover analyses of the columns are carried out to obtain the seismic performance curves of the columns under different vertical pressures by considering various loading and restraint conditions. Finally, the pushover analyses of the soil-structure system are carried out to reproduce the seismic damage of Daikai station and subway tunnel under horizontal and vertical bi-directional seismic effects. The results show that the computed damage is similar to the actual damage. The pushover analysis method, which considers both horizontal and vertical inertia forces of the soil, can be used to simulate the damage and study the collapse mechanism at Daikai station. Compared with the dynamic analysis, the calculation efficiency of the pushover analysis method is significantly higher; it is therefore suggested to use pushover analysis in seismic analysis of underground stations.
Challenges related to seismic performance and seismic mitigation are more pronounced in the presence of weak interlayers compared to typical layered soil conditions. This study focuses on a double-layer double-span rectangular frame subway station structure. A coupled static–dynamic finite element analysis model of the soil-structure system is established by using the finite element software ABAQUS/CAE V 6.14. The research investigates the influence of factors such as interlayer thickness, location, and strength on the seismic response of subway station structures. Furthermore, in order to evaluate the effectiveness of FPB in mitigating seismic effects in the weak interlayer ground, two different schemes are proposed in this paper. One is the structure without FPB and the other is the structure with FPB on the top of the central column. The findings reveal that weak interlayers exert a significant influence on the seismic response of subway station structures, especially when these lower-strength weak interlayers are located within the central portion of the subway station structure and exhibit considerable thickness. The FPB on the top of the central column can reduce the overall lateral stiffness of the subway station structure. This, in turn, results in a slight increase in the deformation of sidewall and inter-story displacement angles, accompanied by a marginal exacerbation of sidewall damage. However, the implementation of FPB effectively reduces the deformation of the central column and substantially mitigates the extent of damage to the central column.
The seismic damage of underground structures has been extensively investigated, and it has been demonstrated that underground structures located at weak interlayer sites are more prone to damage. In this study, a two-story two-span rectangular frame subway station structure is analyzed. A two-dimensional soil-underground structure model is developed using the large-scale finite element analysis software ABAQUS. The equivalent linear soil-underground structure dynamic time-history analysis method is employed to examine the seismic response of underground structures at weak interlayer sites. Variations in the thickness and shear wave velocity of the weak interlayer soil are analyzed. The seismic mitigation effects of split columns and prototype columns in underground structures at weak interlayer sites are systematically compared. The findings indicate that the relative displacement and internal force of key structural components significantly increase when the weak interlayer intersects the underground structure. Furthermore, as the thickness of the interlayer increases, the displacement and internal force also escalate. When the thickness of the weak interlayer remains constant and the shear wave velocity decreases, the relative displacement and internal force of the key structural components gradually intensify. Replacing ordinary columns with split columns substantially reduces the internal force of the middle column, providing an effective seismic mitigation measure for underground structures.
The deformation of surrounding soil primarily governs the behavior of underground structures. Consequently, variations in their external geometry significantly affect their overall seismic response. Moreover, large soil deformations and structural uplift caused by liquefaction severely threaten their seismic safety. While most previous studies have focused on conventional rectangular subway stations, the seismic performance of novel varying-span structures remains largely unexplored. In this study, nonlinear dynamic time-history analyses are conducted to investigate the soil–structure interaction (SSI) of large unequal-span subway stations in liquefiable sites. Furthermore, the seismic responses of both the structure and the surrounding soil are systematically evaluated under various burial depths of the liquefiable layer. Finally, a U-shaped foundation reinforcement method is proposed to mitigate structural uplift. The results show that unequal-span structures suppress liquefaction in lateral soil, whereas significant liquefaction occurs beneath the base slab and cantilevered middle slabs. The burial depth of the liquefiable layer has a negligible effect on the liquefaction state directly under the center span. Regarding structural response, global uplift follows a spatial pattern that peaks at the center span and gradually attenuates laterally. Although the proposed U-shaped reinforcement effectively reduces both total and differential uplift, it does not fundamentally change the underlying liquefaction mechanism. Specifically, reinforcing the soil under cantilevered sections minimizes differential uplift while enhancing the overall economic efficiency of the seismic design. These findings provide a scientific basis for optimizing the seismic resilience of complex underground structures, contributing to the development of resource-efficient and disaster-resilient urban underground infrastructure in liquefaction-prone regions.