Zuzanna Zielinska

Mrs. Zuzanna Zielinska

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

Verified
Journal Article
Open access
PDF file
MWMonika Wróbel
Monika Wróbel
ZZZuzanna Zielinska
Zuzanna Zielinska
LOLukasz Oldak
Lukasz Oldak
AKAleksandra Kalicka
Aleksandra Kalicka
GMGrzegorz Mańka
Grzegorz Mańka
PLPiotr Laudanski
Piotr Laudanski
Endometriosis is a chronic disease in which the endometrium cells are located outside the uterine cavity. The aim of this study was to evaluate circulating 20S proteasome and 20S immunoproteasome levels in plasma and peritoneal fluid in women with and without endometriosis in order to assess their usefulness as biomarkers of disease. Concentrations were measured using surface plasmon resonance imaging biosensors. Patients with suspected endometriosis were included in the study—plasma was collected in 112 cases and peritoneal fluid in 75. Based on the presence of endometriosis lesions detected during laparoscopy, patients were divided into a study group (confirmed endometriosis) and a control group (patients without endometriosis). Proteasome and immunoproteasome levels in both the plasma (p = 0.174; p = 0.696, respectively) and the peritoneal fluid (p = 0.909; p = 0.284, respectively) did not differ between those groups. There was a statistically significant difference in the plasma proteasome levels between patients in the control group and those with mild (Stage I and II) endometriosis (p = 0.047) and in the plasma immunoproteasome levels in patients with ovarian cysts compared to those without (p = 0.017). The results of our study do not support the relevance of proteasome and immunoproteasome determination as biomarkers of the disease but suggest a potentially active role in the pathogenesis of endometriosis.

24 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZuzanna Zielinska
Zuzanna Zielinska
LOLukasz Oldak
Lukasz Oldak
TGTomasz Guszcz
Tomasz Guszcz
AHAdam Hermanowicz
Adam Hermanowicz
Ewa GorodkiewiczEwa Gorodkiewicz
Ewa Gorodkiewicz
A new analytical method, based on SPRi biosensors, has been developed for the simultaneous determination of the pro-angiogenic factors HIF-1α, angiopoietin-2 (ANG-2), and interleukin-1β (IL-1β) in biological fluids. These proteins take part in the process of angiogenesis, i.e., the creation of new blood vessels, which is a key stage of cancer development and metastasis. A separate validation process was carried out for each individual compound, indicating that the method can also be used to study one selected protein. Low values of the limit of detection (LOD) and quantification (LOQ) indicate that the developed method enables the determination of very low concentrations, in the order of pg/mL. The LOD values obtained for HIF-1α, ANG-2, and IL-1β were 0.09, 0.01, and 0.01 pg/mL, respectively. The LOQ values were 0.27, 0.039, and 0.02 pg/mL, and the response ranges of the biosensor were 5.00–100.00, 1.00–20.00, and 1.00–15.00 pg/mL. Moreover, determining the appropriate validation parameters confirmed that the design offers high precision, accuracy, and sensitivity. To prove the usefulness of the biosensor in practice, determinations were made in plasma samples from a control group and from a study group consisting of patients with diagnosed bladder cancer. The preliminary results obtained indicate that this biosensor can be used for broader analyses of bladder cancer. Each of the potential biomarkers, HIF-1α, ANG-2, and IL-1β, produced higher concentrations in the study group than in the control group. These are preliminary studies that serve to develop hypotheses, and their confirmation requires the analysis of a larger number of samples. However, the constructed biosensor is characterized by its ease and speed of measurement, and the method does not require special preparation of samples. SPRi biosensors can be used as a sensitive and highly selective method for determining potential blood biomarkers, which in the future may become part of the routine diagnosis of cancers.

11 May 2025 in Talanta
Verified
Journal Article
Closed access
ACAntony Chirco
Antony Chirco
ZZZuzanna Zielinska
Zuzanna Zielinska
Ewa GorodkiewiczEwa Gorodkiewicz
Ewa Gorodkiewicz
EMElisabetta Meacci
Elisabetta Meacci
GMGiancarlo Margheri
Giancarlo Margheri

19 November 2024 in Talanta
Verified
Journal Article
Closed access
ZZZuzanna Zielinska
Zuzanna Zielinska
LOLukasz Oldak
Lukasz Oldak
Ewa GorodkiewiczEwa Gorodkiewicz
Ewa Gorodkiewicz

17 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
ZZZuzanna Zielinska
Zuzanna Zielinska
LOLukasz Oldak
Lukasz Oldak
JKJoanna Kacperczyk-Bartnik
Joanna Kacperczyk-Bartnik
EKEwa Koc-Żórawska
Ewa Koc-Żórawska
MŻMarcin Żórawski
Marcin Żórawski
Ewa GorodkiewiczEwa Gorodkiewicz
Ewa Gorodkiewicz
A biosensor was developed for the quantification of poly(ADP-ribose) polymerase-1 (PARP-1) in body fluids. An antibody specific for PARP-1 was placed on a chip with cysteamine (linker) and a gold layer. This biosensor has a linear response range (10–1000 pg∙mL−1) under appropriate pH conditions and with an antibody ligand concentration of 5 ng∙mL−1. Plasma samples were diluted with PBS buffer in appropriate quantities so that they fell within the linear range of the calibration curve. The biosensor exhibited suitable precision and accuracy, and good recovery (at levels from 95% to 105%). The method was validated by means of PARP-1 determinations in plasma samples from patients with endometriosis and a control group, using surface plasmon resonance imaging (SPRi) biosensors and an enzyme-linked immunosorbent assay (ELISA) test. The Spearman correlation coefficient was close to 1. PARP-1 may be a marker providing information about pathological changes in the body during endometriosis.