In this study, we investigated the performance and reliability of commercial corrosion sensors for monitoring the integrity of piping systems in various fluid environments as an alternative to ultrasonic transducers. To this end, we investigated pipes’ wall-thinning using commercial electrical resistance (ER), linear polarization resistance (LPR), and ultrasonic transducer (UT) sensors under various operating environments. A pilot-scale closed-loop test bed was built to simulate a real pipeline flow situation, from which the sensor data were collected and analyzed. Experimental results indicate that, in the case of the LPR sensor, it is challenging to accurately measure the corrosion rate when a specific measure exceeds the threshold in a severe corrosion environment. In contrast, the ER sensor could measure metal loss under all conditions and reflect the corresponding characteristics. The metal loss (about 0.25 mm) of the real pipe after the experiment was confirmed to be equal to the metal loss (0.254 mm) measured by the sensor. Furthermore, the regression analysis revealed a high correlation between the results obtained from the ER and UT sensors. Thus, evaluating the remaining thickness of the piping system using the commercial ER sensor is deemed to be effective and reliable.
Stainless steel, which is used in metallic bipolar plates, is generally known to have excellent corrosion resistance, which is achieved by forming oxide films. However, localized corrosion occurs when the oxide films are destroyed by pH and chloride ions. Particularly, since the operating condition of polymer electrolyte membrane fuel cells (PEMFCs) is strongly acidic, the reduced stability of the oxide films leads to the corrosion of the stainless steel. In this research, the electrochemical characteristics of 304L and 316L stainless steels were investigated in an accelerating solution that simulated the cathode condition of PEMFCs with chloride concentrations. Results under all experimental conditions showed that the corrosion current density of 304L stainless steel was at least four times higher than that of 316L stainless steel. Maximum damage depth was measured at 6.136 μm and 9.192 μm for 304L stainless steel and 3.403 μm and 5.631 μm for 316L stainless steel for chloride concentrations of 0 and 1000 ppm, respectively. Furthermore, 304L and 316L stainless steels were found to have uniform and localized corrosion, respectively. The differences in the electrochemical characteristics of 304L and 316L stainless steel are considered to be due to the molybdenum contained in the chemical composition of 316L stainless steel.