Fidencio Tapia

Dr. Fidencio Tapia

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2022 in Materials Today Communications
Verified
Journal Article
Closed access
SRS.L. Rodríguez-Reyna
S.L. Rodríguez-Reyna
CMCristian Mata
Cristian Mata
JDJ.H. Díaz-Aguilera
J.H. Díaz-Aguilera
HAH.R. Acevedo-Parra
H.R. Acevedo-Parra
FTFidencio Tapia
Fidencio Tapia

23 November 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SRS.L. Rodríguez-Reyna
S.L. Rodríguez-Reyna
JDJ.H. Díaz-Aguilera
J.H. Díaz-Aguilera
HAH.R. Acevedo-Parra
H.R. Acevedo-Parra
CLChristian Jesús García López
Christian Jesús García López
EGEmmanuel Gutiérrez
Emmanuel Gutiérrez
FTFidencio Tapia
Fidencio Tapia

1 December 2020 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
RJRobert Jäckel
Robert Jäckel
FTFidencio Tapia
Fidencio Tapia
GGGeydy Gutiérrez-Urueta
Geydy Gutiérrez-Urueta
CJCintia Monreal Jiménez
Cintia Monreal Jiménez

31 May 2019 in The Aeronautical Journal
Verified
Journal Article
Closed access
PDF file
RJR. Jäckel
R. Jäckel
Geydy Gutiérrez-UruetaGeydy Gutiérrez-Urueta
Geydy Gutiérrez-Urueta
FTFidencio Tapia
Fidencio Tapia
CJC. Monreal Jiménez
C. Monreal Jiménez
Aeronautic Pitot probes (PPs) are extremely important for airspeed and altitude measurements in aviation. Failure of the instrument due to clogging caused by ice formation can lead to dangerous situations. In this work, a commercial aeronautic PP was characterised experimentally regarding its inner composition, material properties and its thermal performance in a climatic wind tunnel. Performance runs were taken out in order to analyse the thermal response of the PP under various operating conditions with a particular emphasis on the cooling process in the case of a heating element failure. Data for the thermal conductivity, diffusivity and specific heat for each material forming the PP were obtained. A numerical model to simulate the thermal behaviour of the PP was created using Comsol Multiphysics (CM). Experimental data were compared with their numerical counterparts for model validation purposes. After the model was validated, the operation of the PP in flight conditions was simulated. The failure of the conventional heating system was analysed to obtain the time until the PP reaches a tip temperature where ice formation can be expected. The tip temperature undercut the zero degrees Celsius mark 165 seconds after the heating element was switched off. The data collected in this work can be used to implement and validate mathematical models in order to predict the thermal performance of Pitot probes in flight conditions.

1 October 1997 in Journal of the American Helicopter Society
Verified
Journal Article
Closed access
FTFidencio Tapia
Fidencio Tapia
LSLakshmi N. Sankar
Lakshmi N. Sankar
DSDaniel P. Schrage
Daniel P. Schrage

1 June 2021 in Case Studies in Construction Materials
Verified
Journal Article
Open access
SRSandra L. Rodríguez R.
Sandra L. Rodríguez R.
ODO. Domínguez
O. Domínguez
JDJ.H. Díaz-Aguilera
J.H. Díaz-Aguilera
CLChristian Jesús García López
Christian Jesús García López
FTFidencio Tapia
Fidencio Tapia