Marine microplastics (MPs) contamination has become an enormous hazard to aquatic creatures and human life. For MP identification, many Machine learning (ML) based approaches have been proposed using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR). One major challenge for training MP identification models now is the imbalanced and inadequate samples in MP datasets, especially when these conditions are combined with copolymers and mixtures. To improve the ML performance in identifying MPs, data augmentation method is an effective approach. This work utilizes Explainable Artificial Intelligence (XAI) and Gaussian Mixture Models (GMM) to reveal the influence of FTIR spectral regions in identifying each type of MPs. Based on the identified regions, this work proposes a Fingerprint Region based Data Augmentation (FRDA) method to generate new FTIR data to supplement MP datasets. The evaluation results show that FRDA outperforms the existing spectral data augmentation approaches.
This study developed a 1:2 scale model using T-shape steel with one-side bolts to connect a square steel tube column to an H-shape steel beam for a quasi-static test to investigate the mechanical properties and seismic behavior of semi-rigid joints. Within the study context, the joint’s failure characteristics, hysteresis characteristics, and strain tendency under cyclic load were determined. In addition, this research analyzed the force characteristics and seismic performance of such joints based on the test outcomes. In order to further study the seismic performance of such joints, ABAQUS finite element software was used to establish a numerical model and perform parametric analysis. The findings indicated that the force on both sides of the joint is inconsistent, resulting in different seismic performances on both sides of the joint. Selecting a T-shape steel connector significantly affects the seismic capacity of beam–column joints. The seismic capacity of joints can be improved by increasing the size of the T-shape steel. The stability of one-side bolts under repeated load is good, and their strain value rises steadily. Hence, this type of one-side bolt is suitable for connecting closed steel tube columns and other components. In general, the seismic performance of square steel tube column–H-shape steel beam joints with one-side bolts and a T-shape steel connection is good and is recommended for practical engineering.
Fatigue life is a crucial design factor which dictates the safe operation of the wind turbines, but it is influenced by uncertain factors such as environmental loads, analytical models, material properties, and manufacturing methods. In this study, a 1.5 MW wind turbine was monitored in operation to understand the fatigue mechanism and enhance wind turbine design. The influence of different operating conditions on fatigue damage was analyzed by correlating strain monitoring data with supervisory control and data acquisition (SCADA) data. Furthermore, a fatigue evaluation method based on measured strain data was proposed. Fatigue damage increases with the increase of wind and rotation speed. More than 50% of the damage occurred at the rated rotation speed state, the corresponding wind speed was greater than the rated wind speed and the pitch control system was active. The findings of this study provide insights for investigating the real fatigue state of similar wind turbine towers and improving the return on investment by closely estimating their service life.
A detailed nonlinear finite element model was established based on completed experiments to investigate the behavior of a blind-bolted T-stub composite joint that connects a composite beam to a concrete-filled square tube column. This was accomplished by comparing the experimental results and the finite element simulation results using the hysteresis curve, failure mode, plastic deformation and strain development of the T-stub to ensure the reliability and accuracy of the finite element model. A parametric study was carried out on the base model to expand the library of test data. It was observed from the comparison that the proposed nonlinear FE model predicted the behavior of the composite joint. The wall thickness of the column and reinforcement ratio had a significant influence on the ultimate bending moment of the composite joint and the performance of the composite joint was mainly controlled by the reinforcement ratio when the concrete slab was under a positive bending moment. The flange of the T-stub, the web of the T-stub and the axial compression ratio had little effect on the performance of the composite joint.
1 February 2021 in IOP Conference Series: Earth and Environmental Science
A reciprocating force loading test was performed of a single-layer shear-yield eccentric brace frame specimen, and the finite element model of stiffeners of several energy-dissipating beam segments with different spacing is established. On the basis of verifying the validity of the finite element analysis, a non-linear numerical analysis of its hysteretic performance is performed, and the bearing capacity, initial stiffness, stiffness degradation and energy dissipation capacity of different model structures are analyzed. Studies have shown that appropriately reducing the spacing of the stiffeners in the energy dissipating beam segments can increase the load-bearing capacity, initial stiffness and energy dissipation capacity of the component, but the residual stiffness of the structure can be reduced.
This paper studies the seismic performance of spatial semi-rigid beam-column connections with T-stubs. The middle column connection of steel frame as the research objects and there is one spatial T-stub connection specimen and one plane T-stub connection specimen. Spatial quasi-static tests and finite element analysis are carried out, which load is applied to the column. According to the results of quasi-static tests and finite element calculations, difference of joints' rotational stiffness, hysteretic property, ductility coefficient and energy dissipation characteristics are analyzed. It is verified that the mechanical characteristics of spatial semirigid joint under spatial load are different from plane semirigid joint under plane load.