Nathalia Oezau Gomes

Ms. Nathalia Oezau Gomes

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
GRGisela Ibáñez Redín
Gisela Ibáñez Redín
GCGiovana Rosso Cagnani
Giovana Rosso Cagnani
NGNathalia Oezau Gomes
Nathalia Oezau Gomes
Paulo A. Raymundo-PereiraPaulo A. Raymundo-Pereira
Paulo A. Raymundo-Pereira
SMSergio A. S. Machado
Sergio A. S. Machado
OOOsvaldo N. Oliveira
Osvaldo N. Oliveira

4 February 2022 in Chemical Engineering Journal
Verified
Journal Article
Closed access
PRPaulo A. Raymundo-Pereira
Paulo A. Raymundo-Pereira
NGNathalia Oezau Gomes
Nathalia Oezau Gomes
SMSergio A.S. Machado
Sergio A.S. Machado
OOOsvaldo N. Oliveira
Osvaldo N. Oliveira

14 July 2023 in Chemical Engineering Journal
Verified
Journal Article
Closed access
NGNathalia Oezau Gomes
Nathalia Oezau Gomes
STSamiris Côcco Teixeira
Samiris Côcco Teixeira
MCMarcelo L. Calegaro
Marcelo L. Calegaro
SMSergio A.S. Machado
Sergio A.S. Machado
NSNilda de Fátima Ferreira Soares
Nilda de Fátima Ferreira Soares
PRPaulo A. Raymundo-Pereira
Paulo A. Raymundo-Pereira

8 May 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
NGNathalia Oezau Gomes
Nathalia Oezau Gomes
RPRafaella Takehara Paschoalin
Rafaella Takehara Paschoalin
SBStanley Bilatto
Stanley Bilatto
ASAmanda Rinaldi Sorigotti
Amanda Rinaldi Sorigotti
CFCristiane S. Farinas
Cristiane S. Farinas
Paulo A. Raymundo-PereiraPaulo A. Raymundo-Pereira
Paulo A. Raymundo-Pereira
We introduce a bifunctional architecture to construct biosensors on solution-blow spinning fiber mats of polylactic acid (PLA) and polyethylene glycol (PEG). PLA/PEG mats acted as substrate for printing electrodes and as matrix to immobilize glucose oxidase (GOx). Prussian Blue nanoparticles (PB) decorated working electrodes to detect H2O2 from enzymatic catalysis at a low applied potential (0 V vs. Ag/AgCl) with detection limit of 0.197 mM. The inexpensive bifunctional device (<US $0.25 per unit) exhibited a rapid response, long lifetime, and performance similar to the standard method for glucose monitoring in human urine samples. The PLA/PEG mats are sustainable alternative for biosensing and wearable applications.

1 August 2023
Verified
Thesis
Open access
PDF file
NGNathalia Oezau Gomes
Nathalia Oezau Gomes
O comprometimento das fontes de águas naturais pelos poluentes emergentes é um problema eminente para saúde pública e desenvolvimento das nações. Então, desenvolver novas estratégias para controle de poluentes...