Edward Lemaire

Prof. Edward Lemaire

University of Ottawa, ON, Canada
+1
orcid

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
JHJennifer Howcroft
Jennifer Howcroft
JKJonathan Kofman
Jonathan Kofman
Edward LemaireEdward Lemaire
Edward Lemaire
Falls are a prevalent issue in the geriatric population and can result in damaging physical and psychological consequences. Fall risk assessment can provide information to enable appropriate interventions for those at risk of falling. Wearable inertial-sensor-based systems can provide quantitative measures indicative of fall risk in the geriatric population.

17 April 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NCNicole A. Capela
Nicole A. Capela
Edward LemaireEdward Lemaire
Edward Lemaire
NBNatalie Baddour
Natalie Baddour
Human activity recognition (HAR), using wearable sensors, is a growing area with the potential to provide valuable information on patient mobility to rehabilitation specialists. Smartphones with accelerometer and gyroscope sensors are a convenient, minimally invasive, and low cost approach for mobility monitoring. HAR systems typically pre-process raw signals, segment the signals, and then extract features to be used in a classifier. Feature selection is a crucial step in the process to reduce potentially large data dimensionality and provide viable parameters to enable activity classification. Most HAR systems are customized to an individual research group, including a unique data set, classes, algorithms, and signal features. These data sets are obtained predominantly from able-bodied participants. In this paper, smartphone accelerometer and gyroscope sensor data were collected from populations that can benefit from human activity recognition: able-bodied, elderly, and stroke patients. Data from a consecutive sequence of 41 mobility tasks (18 different tasks) were collected for a total of 44 participants. Seventy-six signal features were calculated and subsets of these features were selected using three filter-based, classifier-independent, feature selection methods (Relief-F, Correlation-based Feature Selection, Fast Correlation Based Filter). The feature subsets were then evaluated using three generic classifiers (Naïve Bayes, Support Vector Machine, j48 Decision Tree). Common features were identified for all three populations, although the stroke population subset had some differences from both able-bodied and elderly sets. Evaluation with the three classifiers showed that the feature subsets produced similar or better accuracies than classification with the entire feature set. Therefore, since these feature subsets are classifier-independent, they should be useful for developing and improving HAR systems across and within populations.

24 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SPScott Pardoel
Scott Pardoel
JKJonathan Kofman
Jonathan Kofman
JNJulie Nantel
Julie Nantel
Edward LemaireEdward Lemaire
Edward Lemaire
Freezing of gait (FOG) is a serious gait disturbance, common in mid- and late-stage Parkinson’s disease, that affects mobility and increases fall risk. Wearable sensors have been used to detect and predict FOG with the ultimate aim of preventing freezes or reducing their effect using gait monitoring and assistive devices. This review presents and assesses the state of the art of FOG detection and prediction using wearable sensors, with the intention of providing guidance on current knowledge, and identifying knowledge gaps that need to be filled and challenges to be considered in future studies. This review searched the Scopus, PubMed, and Web of Science databases to identify studies that used wearable sensors to detect or predict FOG episodes in Parkinson’s disease. Following screening, 74 publications were included, comprising 68 publications detecting FOG, seven predicting FOG, and one in both categories. Details were extracted regarding participants, walking task, sensor type and body location, detection or prediction approach, feature extraction and selection, classification method, and detection and prediction performance. The results showed that increasingly complex machine-learning algorithms combined with diverse feature sets improved FOG detection. The lack of large FOG datasets and highly person-specific FOG manifestation were common challenges. Transfer learning and semi-supervised learning were promising for FOG detection and prediction since they provided person-specific tuning while preserving model generalization.

21 February 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JHJennifer Howcroft
Jennifer Howcroft
Edward LemaireEdward Lemaire
Edward Lemaire
JKJonathan Kofman
Jonathan Kofman
WMWilliam E McIlroy
William E McIlroy
Maintaining and controlling postural balance is important for activities of daily living, with poor postural balance being predictive of future falls. This study investigated eyes open and eyes closed standing posturography with elderly adults to identify differences and determine appropriate outcome measure cut-off scores for prospective faller, single-faller, multi-faller, and non-faller classifications. 100 older adults (75.5 ± 6.7 years) stood quietly with eyes open and then eyes closed while Wii Balance Board data were collected. Range in anterior-posterior (AP) and medial-lateral (ML) center of pressure (CoP) motion; AP and ML CoP root mean square distance from mean (RMS); and AP, ML, and vector sum magnitude (VSM) CoP velocity were calculated. Romberg Quotients (RQ) were calculated for all parameters. Participants reported six-month fall history and six-month post-assessment fall occurrence. Groups were retrospective fallers (24), prospective all fallers (42), prospective fallers (22 single, 6 multiple), and prospective non-fallers (47). Non-faller RQ AP range and RQ AP RMS differed from prospective all fallers, fallers, and single fallers. Non-faller eyes closed AP velocity, eyes closed VSM velocity, RQ AP velocity, and RQ VSM velocity differed from multi-fallers. RQ calculations were particularly relevant for elderly fall risk assessments. Cut-off scores from Clinical Cut-off Score, ROC curves, and discriminant functions were clinically viable for multi-faller classification and provided better accuracy than single-faller classification. RQ AP range with cut-off score 1.64 could be used to screen for older people who may fall once. Prospective multi-faller classification with a discriminant function (-1.481 + 0.146 x Eyes Closed AP Velocity—0.114 x Eyes Closed Vector Sum Magnitude Velocity—2.027 x RQ AP Velocity + 2.877 x RQ Vector Sum Magnitude Velocity) and cut-off score 0.541 achieved an accuracy of 84.9% and is viable as a screening tool for older people at risk of multiple falls.

24 March 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
JHJennifer Howcroft
Jennifer Howcroft
JKJonathan Kofman
Jonathan Kofman
Edward LemaireEdward Lemaire
Edward Lemaire
Wearable sensors can provide quantitative, gait-based assessments that can translate to point-of-care environments. This investigation generated elderly fall-risk predictive models based on wearable-sensor-derived gait data and prospective fall occurrence, and identified the optimal sensor type, location, and combination for single and dual-task walking. 75 individuals who reported six month prospective fall occurrence (75.2 ± 6.6 years; 47 non-fallers and 28 fallers) walked 7.62 m under single-task and dual-task conditions while wearing pressure-sensing insoles and tri-axial accelerometers at the head, pelvis, and left and right shanks. Fall-risk classification models were assessed for all sensor combinations and three model types: neural network, naïve Bayesian, and support vector machine. The best performing model used a neural network, dual-task gait data, and input parameters from head, pelvis, and left shank accelerometers (accuracy = 57%, sensitivity = 43%, and specificity = 65%). The best single-sensor model used a neural network, dual-task gait data, and pelvis accelerometer parameters (accuracy = 54%, sensitivity = 35%, and specificity = 67%). Single-task and dual-task gait assessments provided similar fall-risk model performance. Fall-risk predictive models developed for point-of-care environments should use multi-sensor dual-task gait assessment with the pelvis location considered if assessment is limited to a single sensor.

1 September 2011 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PLPascal Laferriere
Pascal Laferriere
Edward LemaireEdward Lemaire
Edward Lemaire
ACAdrian D. C. Chan
Adrian D. C. Chan
For many electromyography (EMG) applications, a suitable dry electrode would simplify practical implementation of an EMG recording system. Wearable mobility monitoring is an example of such a system. Therefore, surface EMG signals, from Fraunhofer Institute for Biomedical Engineering (IBMT) flexible dry electrodes and Orbital Research electrodes, were compared to signals from conventional Ag/AgCl electrodes. EMG measurements were performed on the right tibialis anterior for a range of different activities, such as light twitches, isometric contractions, jumping, and walking. Signal feature comparisons, skin preparation effects (i.e., cleaning with isopropyl alcohol), and impedance-noise analyses were performed. Results showed that both dry electrodes had comparable sensitivity to the standard Ag/AgCl electrodes for detecting small unloaded muscle contractions and large loaded contractions. Results also showed that noise content and impedance are weakly correlated and skin preparation methods did not have a positive effect on skin/electrode impedance.