Hisashi Nakano

Dr. Hisashi Nakano

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
HNHisashi Nakano
Hisashi Nakano
STSatoshi Tanabe
Satoshi Tanabe
SUSatoru Utsunomiya
Satoru Utsunomiya
TYTakumi Yamada
Takumi Yamada
RSRyuta Sasamoto
Ryuta Sasamoto
HAHidefumi Aoyama
Hidefumi Aoyama
In conventional stereotactic radiosurgery (SRS), treatment of multiple brain metastases using multiple isocenters is time‐consuming resulting in long dose delivery times for patients. A single‐isocenter technique has been developed which enables the simultaneous irradiation of multiple targets at one isocenter. This technique requires accurate positioning of the patient to ensure optimal dose coverage. We evaluated the effect of six degrees of freedom (6DoF) setup errors in patient setups on SRS dose distributions for multiple brain metastases using a single‐isocenter technique. We used simulated spherical gross tumor volumes (GTVs) with diameters ranging from 1.0 to 3.0 cm. The distance from the isocenter to the target's center was varied from 0 to 15 cm. We created dose distributions so that each target was entirely covered by 100% of the prescribed dose. The target's position vectors were rotated from 0°–2.0° and translated from 0–1.0 mm with respect to the three axes in space. The reduction in dose coverage for the targets for each setup error was calculated and compared with zero setup error. The calculated margins for the GTV necessary to satisfy the tolerance values for loss of GTV coverage of 3% to 10% were defined as coverage‐based margins. In addition, the maximum isocenter to target distance for different 6DoF setup errors was calculated to satisfy the tolerance values. The dose coverage reduction and coverage‐based margins increased as the target diameter decreased, and the distance and 6DoF setup error increased. An increase in setup error when a single‐isocenter technique is used may increase the risk of missing the tumor; this risk increases with increasing distance from the isocenter and decreasing tumor size.

3 January 2021 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
HNHisashi Nakano
Hisashi Nakano
STSatoshi Tanabe
Satoshi Tanabe
TYTakumi Yamada
Takumi Yamada
SUSatoru Utsunomiya
Satoru Utsunomiya
TTTakeshi Takizawa
Takeshi Takizawa
HIHiroyuki Ishikawa
Hiroyuki Ishikawa

21 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HNHisashi Nakano
Hisashi Nakano
DKDaisuke Kawahara
Daisuke Kawahara
KOKaoru Ono
Kaoru Ono
YAYukio Akagi
Yukio Akagi
YHYutaka Hirokawa
Yutaka Hirokawa
The effect of dose-delivery time with flattening filter (FF) and flattening filter-free (FFF) photon beams based on microdosimetric kinetic model (MKM) was investigated in this study. Monte Carlo simulation with the particle and heavy ion transport code system (PHITS) was performed to calculate the dose-mean lineal energy yD (keV/μm) of FF and FFF 6 MV photon beams using the IAEA phase-space files of Varian TrueBeam linear accelerator. Human non-small cell lung cancer NCI-H460 cells were used to determine the MKM parameters under the condition that dose-delivery times with continuous irradiation were 1, 5, 10, 30, and 60 min, and the adsorbed dose was 2, 4, and 8 Gy in this study. In addition, the relative biological effectiveness (RBE) of FF and FFF photon beams were calculated for evaluating the effect of dose delivery time. The RBE of FF decreased to 99.8% and 97.5% with 5 and 60 min for 2 Gy in comparison to 99.6% and 95.1% for 8 Gy, respectively. Meanwhile, that of FFF decreased to 99.5% and 94.9% with 5 and 60 min for 2 Gy in comparison to 99.5% and 94.9% for 8 Gy, respectively. Dose-delivery time has an effect on the RBE with photon beams. In other words, the dose-delivery time should be considered during radiation therapy. Furthermore, FFF photon beams were an effective irradiation method compared to FF in dose-delivery time on account of improving clinic throughput.

20 June 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
HNHisashi Nakano
Hisashi Nakano
STSatoshi Tanabe
Satoshi Tanabe
RSRyuta Sasamoto
Ryuta Sasamoto
TTTakeshi Takizawa
Takeshi Takizawa
SUSatoru Utsunomiya
Satoru Utsunomiya
HIHiroyuki Ishikawa
Hiroyuki Ishikawa
Purpose We calculated the dosimetric indices and estimated the tumor control probability (TCP) considering six degree-of-freedom (6DoF) patient setup errors in stereotactic radiosurgery (SRS) using a single-isocenter technique. Methods We used simulated spherical gross tumor volumes (GTVs) with diameters of 1.0 cm (GTV 1), 2.0 cm (GTV 2), and 3.0 cm (GTV 3), and the distance (d) between the target center and isocenter was set to 0, 5, and 10 cm. We created the dose distribution by convolving the blur component to uniform dose distribution. The prescription dose was 20 Gy and the dose distribution was adjusted so that D95 (%) of each GTV was covered by 100% of the prescribed dose. The GTV was simultaneously rotated within 0°–1.0° (δR) around the x-, y-, and z-axes and then translated within 0–1.0 mm (δT) in the x-, y-, and z-axis directions. D95, conformity index (CI), and conformation number (CN) were evaluated by varying the distance from the isocenter. The TCP was estimated by translating the calculated dose distribution into a biological response. In addition, we derived the x-y-z coordinates with the smallest TCP reduction rate that minimize the sum of squares of the residuals as the optimal isocenter coordinates using the relationship between 6DoF setup error, distance from isocenter, and GTV size. Results D95, CI, and CN were decreased with increasing isocenter distance, decreasing GTV size, and increasing setup error. TCP of GTVs without 6DoF setup error was estimated to be 77.0%. TCP were 25.8% (GTV 1), 35.0% (GTV 2), and 53.0% (GTV 3) with (d, δT, δR) = (10 cm, 1.0 mm, 1.0°). The TCP was 52.3% (GTV 1), 54.9% (GTV 2), and 66.1% (GTV 3) with (d, δT, δR) = (10 cm, 1.0 mm, 1.0°) at the optimal isocenter position. Conclusion The TCP in SRS for multiple brain metastases with a single-isocenter technique may decrease with increasing isocenter distance and decreasing GTV size when the 6DoF setup errors are exceeded (1.0 mm, 1.0°). Additionally, it might be possible to better maintain TCP for GTVs with 6DoF setup errors by using the optimal isocenter position.

21 November 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
NINatsuki Ishizaka
Natsuki Ishizaka
TKTomotaka Kinoshita
Tomotaka Kinoshita
MSMadoka Sakai
Madoka Sakai
STShunpei Tanabe
Shunpei Tanabe
HNHisashi Nakano
Hisashi Nakano
SUSatoru Utsunomiya
Satoru Utsunomiya
Purpose: We sought to develop machine learning models to predict the results of patient‐specific quality assurance (QA) for volumetric modulated arc therapy (VMAT), which were represented by several dose‐evaluation metrics—including the gamma passing rates (GPRs)—and criteria based on the radiomic features of 3D dose distribution in a phantom.Methods: A total of 4,250 radiomic features of 3D dose distribution in a cylindrical dummy phantom for 140 arcs from 106 clinical VMAT plans were extracted. We obtained the following dose‐evaluation metrics: GPRs with global and local normalization, the dose difference (DD) in 1% and 2% passing rates (DD1% and DD2%) for 10% and 50% dose threshold, and the distance‐to‐agreement in 1‐mm and 2‐mm passing rates (DTA1 mm and DTA2 mm) for 0.5%/mm and 1.0%.mm dose gradient threshold determined by measurement using a diode array in patient‐specific QA. The machine learning regression models for predicting the values of the dose‐evaluation metrics using the radiomic features were developed based on the elastic net (EN) and extra trees (ET) models. The feature selection and tuning of hyperparameters were performed with nested cross‐validation in which four‐fold cross‐validation is used within the inner loop, and the performance of each model was evaluated in terms of the root mean square error (RMSE), the mean absolute error (MAE), and Spearman's rank correlation coefficient.Results: The RMSE and MAE for the developed machine learning models ranged from <1% to nearly <10% depending on the dose‐evaluation metric, the criteria, and dose and dose gradient thresholds used for both machine learning models. It was advantageous to focus on high dose region for predicating global GPR, DDs, and DTAs. For certain metrics and criteria, it was possible to create models applicable for patients’ heterogeneity by training only with dose distributions in phantom.Conclusions: The developed machine learning models showed high performance for predicting dose‐evaluation metrics especially for high dose region depending on the metric and criteria. Our results demonstrate that the radiomic features of dose distribution can be considered good indicators of the plan complexity and useful in predicting measured dose evaluation metrics.

13 October 2020 in Cancers
Verified
Journal Article
Open access
PDF file
MOMarina Ohkoshi-Yamada
Marina Ohkoshi-Yamada
KKKenya Kamimura
Kenya Kamimura
OSOsamu Shibata
Osamu Shibata
SMShinichi Morita
Shinichi Morita
MKMotoki Kaidu
Motoki Kaidu
STShuji Terai
Shuji Terai
This study investigated the efficacy and safety of radiotherapy as part of multidisciplinary therapy for advanced hepatocellular carcinoma (HCC). Clinical data of 49 HCC patients treated with radiotherapy were assessed retrospectively. The efficacy of radiotherapy was assessed by progression-free survival, disease control rate, and overall survival. Safety was assessed by symptoms and hematological assay, and changes in hepatic reserve function were determined by Child–Pugh score and albumin–bilirubin (ALBI) score. Forty patients underwent curative radiotherapy, and nine patients with portal vein tumor thrombus (PVTT) underwent palliative radiotherapy as part of multidisciplinary therapy. Local disease control for curative therapy was 80.0% and stereotactic body radiotherapy was 86.7% which was greater than that of conventional radiotherapy (60.0%). Patients with PVTT had a median observation period of 651 days and 75% three-year survival when treated with multitherapy, including radiotherapy for palliative intent, transcatheter arterial chemoembolization, and administration of molecular targeted agents. No adverse events higher than grade 3 and no changes in the Child–Pugh score and ALBI score were seen. Radiotherapy is safe and effective for HCC treatment and can be a part of multidisciplinary therapy.