Swagat Pati

Dr. Swagat Pati


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BMBhabasis Mohapatra
Bhabasis Mohapatra
BSBinod Kumar Sahu
Binod Kumar Sahu
SPSwagat Pati
Swagat Pati
Mohit BajajMohit Bajaj
Mohit Bajaj
VBVojtech Blazek
Vojtech Blazek
SMStanislav Misak
Stanislav Misak
Over the past years, the use of renewable energy sources (RESs) has grown significantly as a means of providing clean energy to counteract the devastating effects of climate change. Reducing energy costs and pollution have been the primary causes of the rise in solar photovoltaic (PV) system integrations with the grid in recent years. A load that is locally connected to a GCPV requires both active and reactive power control. In order to control both active and reactive power, MAs and advanced controllers are essential. Researchers have used one of the recently developed MAs, known as the CAOA, which is based on mathematical arithmetic operators to tackle a few real-world optimization problems. Some disadvantages of CAOA include its natural tendency to converge to a local optimum and its limited capacity for exploration. By merging the PSO and CAOA methodologies, this article suggests the IAOA. To show how applicable IAOA is, its performance has been evaluated using four benchmark functions. The implementation of an IAOA-based ST-SMC for active and reactive power control is addressed in this article, which offers an innovative approach of research. In comparison to PSO-based ST-SMC and CAOA-based ST-SMC, the proposed IAOA-based ST-SMC appears to be superior, with settling time for active and reactive power control at a minimum of 0.01012 s and 0.5075 s. A real-time OPAL-RT 4510 simulator is used to validate the performance results of a 40 kW GCPV system after it has been investigated in the MATLAB environment.

22 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
BMBhabasis Mohapatra
Bhabasis Mohapatra
BSBinod Kumar Sahu
Binod Kumar Sahu
SPSwagat Pati
Swagat Pati
Mohit BajajMohit Bajaj
Mohit Bajaj
VBVojtěch Blažek
Vojtěch Blažek
MAMosleh Alharthi
Mosleh Alharthi
Renewable energy sources have power quality and stability issues despite having vast benefits when integrated with the utility grid. High currents and voltages are introduced during the disconnection or injection from or into the power system. Due to excessive inverter switching frequencies, distorted voltage waveforms and high distortions in the output current may be observed. Hence, advancing intelligent and robust optimization techniques along with advanced controllers is the need of the hour. Therefore, this article presents an improved arithmetic optimization algorithm and an offset hysteresis band current controller. Conventional hysteresis band current controllers (CHCCs) offer substantial advantages such as fast dynamic response, over-current, and robustness in response to impedance variations, but they suffer from variable switching frequency. The offset hysteresis band current controller utilizes the zero-crossing time of the current error for calculating the lower/upper hysteresis bands after the measurement of half of the error current period. The duty cycle and hysteresis bands are considered as design variables and are optimally designed by minimizing the current error and the switching frequency. It is observed that the proposed controller yields a minimum average switching frequency of 2.33 kHz and minimum average switching losses of 9.07 W in comparison to other suggested controllers. Results are validated using MATLAB/Simulink environment followed by real-time simulator OPAL-RT 4510.

6 April 2025 in Green Energy and Intelligent Transportation
Verified
Journal Article
Open access
KSKalpana Bijayeeni Samal
Kalpana Bijayeeni Samal
SPSwagat Pati
Swagat Pati
RSRenu Sharma
Renu Sharma

31 July 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SPSwagat Pati
Swagat Pati
ACAbhijeet Choudhury
Abhijeet Choudhury
APAkansha Pujari
Akansha Pujari
RSRenu Sharma
Renu Sharma
SKSanjeeb Kumar Kar
Sanjeeb Kumar Kar
In this work, a nine-switch converter-based electric spring topology has been proposed for the power control of a microgrid system. Generally, the control algorithms which are used for the control of isolated systems are based upon the ‘generation following load' strategy, where the generation is varied according to the load demand. But in the case of the electric spring, the control algorithm is modified to a ‘load following generation' strategy, where the load is adjusted according to the generation. Mostly in this paper, emphasis is given to varying the load power according to the instantaneous power generation in the system so that the system voltage and frequency can be kept constant. To achieve that, the loads are first segregated into two types i.e., the critical load which is voltage sensitive, and the non-critical load which is voltage insensitive. In the electric spring concept, the voltage of the non-critical load is varied to vary the non-critical load power to keep the critical load voltage constant. Authors have also proposed a nine-switch converter (NSC) that enables the combined operation of series-shunt compensators, where one side of the NSC acts as an Electric spring and the other side acts as a shunt converter to integrate the PV system and controls its power flow. The isolated hybrid microgrid system comprises a 22kW self-excited induction generator, an 18Kw Photovoltaic system housing a Battery energy storage system, and loads. The entire system is simulated and modeled using Matlab/Simulink 2018(a) and verified using OPAL-RT 4510.

17 July 2023 in IEEE Access
Verified
Journal Article
Open access
SMSoumya Mohanty
Soumya Mohanty
SPSwagat Pati
Swagat Pati
SKSanjeeb Kumar Kar
Sanjeeb Kumar Kar
HKhabib kraiem
habib kraiem
Aymen FlahAymen Flah
Aymen Flah
MAMohammed Alqarni
Mohammed Alqarni
The smart load phenomenon of electric spring has been proven to be an important aid to the distribution network in terms of voltage stability. While the performance of ES is commendable, its operational range presents a significant challenge. The effectiveness of an ES depends on various factors, including the choice of control structure, smart load ratio, ES placement, and non-critical load power factor. To address the challenges regarding the noncritical load power factor, this study proposes a novel hybrid control structure that combines two well-established schemes: quadrature voltage injection and in-phase voltage injection. The performance of the proposed scheme is evaluated under variable non-critical load resistance, inductance, and power factors, with the results presented in this paper. Additionally, the sensitivity of the proposed scheme is analyzed for different scenarios, such as varying non-critical load power factors, resistances, and inductances using MATLAB/Simulink environment. A comparative sensitivity analysis is conducted between the proposed scheme and the quadrature and in-phase voltage injection schemes, and the findings are also documented. Further a real-time validation of the proposed control scheme, as well as the other schemes, is conducted using the OPAL-RT 4510 real-time simulator. At last, THD analysis along with a competitive study is done with other pre-published control structure to showcase the superiority of the proposed control scheme.

18 January 2024 in e-Prime - Advances in Electrical Engineering, Electronics and Energy
Verified
Journal Article
Open access
KSKalpana Bijayeeni Samal
Kalpana Bijayeeni Samal
SPSwagat Pati
Swagat Pati
RSRenu Sharma
Renu Sharma