VIPUL A SHAH

Dr. VIPUL A SHAH

Instrumentation and control engineering, Dharamsinh Desai University, Nadiād, India
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JBJignesh Bhatt
Jignesh Bhatt
VIPUL A SHAHVIPUL A SHAH
VIPUL A SHAH
OJOmkar Jani
Omkar Jani

15 April 2022 in Automatika
Verified
Journal Article
Open access
Himanshukumar Rajendrabhai PatelHimanshukumar Rajendrabhai Patel
Himanshukumar Rajendrabhai Patel
VIPUL A SHAHVIPUL A SHAH
VIPUL A SHAH
A new optimum interval type-2 fuzzy fractional-order controller for a class of nonlinear systems with incipient actuator and system component faults is introduced in this study. The faults of the actuator and system component (leak) are taken into account using an additive model. The Interval Type-2 Fuzzy Sets (IT2FS) is used to design an optimal fuzzy fractional order controller, and two different nature inspired metaheuristic algorithms, Follower Pollination Algorithm (FPA) and Genetic Algorithm (GA), are used to optimize the parameters of the fuzzy PID controller and Interval Type-2 Fuzzy Tilt-Integral-Derivative Controller (IT2FTID) for nonlinear system. The suggested control approach consists of two parts: an Interval Type-2 Fuzzy Logic Controller (IT2FLC) controller and a fractional order TID controller. Additionally, the two inputs of the IT2FLC are also calibrated using two fine tuning parameters β1 and β2, respectively. The stability of the proposed controller is presented with some conditions. In addition to unknown dynamics, some unknown process disturbances, such as rapid changes in the control variable, are taken into account to check the efficacy of the proposed control scheme. Two nonlinear conical two-tank level systems are used in the simulation as a case study. The performance of the suggested approach is also compared to that of a widely recognized Interval Type-2 Fuzzy Proportional-Integral-Derivative (IT2FPID) Controller. Finally, the proposed control scheme's fault-tolerant behaviour is demonstrated using fault-recovery time results and statistical Z-tests for both controllers, and the proposed IT2FTID controller's effectiveness is demonstrated when compared to IT2FPID and existing passive fault tolerant controllers in recent literature.

11 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
Himanshukumar Rajendrabhai PatelHimanshukumar Rajendrabhai Patel
Himanshukumar Rajendrabhai Patel
VIPUL A SHAHVIPUL A SHAH
VIPUL A SHAH
This paper deals with a methodical design approach of fault-tolerant controller that gives assurance for the the stabilization and acceptable control performance of the nonlinear systems which can be described by Takagi–Sugeno (T–S) fuzzy models. Takagi–Sugeno fuzzy model gives a unique edge that allows us to apply the traditional linear system theory for the investigation and blend of nonlinear systems by linear models in a different state space region. The overall fuzzy model of the nonlinear system is obtained by fuzzy combination of the all linear models. After that, based on this linear model, we employ parallel distributed compensation for designing linear controllers for each linear model. Also this paper reports of the T–S fuzzy system with less conservative stabilization condition which gives decent performance. However, the controller synthesis for nonlinear systems described by the T–S fuzzy model is a complicated task, which can be reduced to convex problems linking with linear matrix inequalities (LMIs). Further sufficient conservative stabilization conditions are represented by a set of LMIs for the Takagi–Sugeno fuzzy control systems, which can be solved by using MATLAB software. Two-rule T–S fuzzy model is used to describe the nonlinear system and this system demonstrated with proposed fault-tolerant control scheme. The proposed fault-tolerant controller implemented and validated on three interconnected conical tank system with two constraints in terms of faults, one issed to build the actuator and sond is system component (leak) respectively. The MATLAB Simulink platform with linear fuzzy models and an LMI Toolbox was used to solve the LMIs and determine the controller gains subject to the proposed design approach.

12 February 2021 in International Journal of Intelligent Computing and Cybernetics
Verified
Journal Article
Closed access
Himanshukumar Rajendrabhai PatelHimanshukumar Rajendrabhai Patel
Himanshukumar Rajendrabhai Patel
VIPUL A SHAHVIPUL A SHAH
VIPUL A SHAH
Purpose: The two-tank level control system is one of the real-world's second-order system (SOS) widely used as the process control in industries. It is normally operated under the Proportional integral and derivative (PID) feedback control loop. The conventional PID controller performance degrades significantly in the existence of modeling uncertainty, faults and process disturbances. To overcome these limitations, the paper suggests an interval type-2 fuzzy logic based Tilt-Integral-Derivative Controller (IT2TID) which is modified structure of PID controller.Design/methodology/approach: In this paper, an optimization IT2TID controller design for the conical, noninteracting level control system is presented. Regarding to modern optimization context, the flower pollination algorithm (FPA), among the most coherent population-based metaheuristic optimization techniques is applied to search for the appropriate IT2FTID's and IT2FPID's parameters. The proposed FPA-based IT2FTID/IT2FPID design framework is considered as the constrained optimization problem. System responses obtained by the IT2FTID controller designed by the FPA will be differentiated with those acquired by the IT2FPID controller also designed by the FPA.Findings: As the results, it was found that the IT2FTID can provide the very satisfactory tracking and regulating responses of the conical two-tank noninteracting level control system superior as compared to IT2FPID significantly under the actuator and system component faults. Additionally, statistical Z-test carried out for both the controllers and an effectiveness of the proposed IT2FTID controller is proven as compared to IT2FPID and existing passive fault tolerant controller in recent literature.Originality/value: Application of new metaheuristic algorithm to optimize interval type-2 fractional order TID controller for nonlinear level control system with two type of faults. Also, proposed method will compare with other method and statistical analysis will be presented.


2 June 2022 in International Journal of Intelligent Computing and Cybernetics
Verified
Journal Article
Closed access
Himanshukumar Rajendrabhai PatelHimanshukumar Rajendrabhai Patel
Himanshukumar Rajendrabhai Patel
VIPUL A SHAHVIPUL A SHAH
VIPUL A SHAH
Purpose: In recent times, fuzzy logic is gaining more and more attention, and this is because of the capability of understanding the functioning of the system as per human knowledge-based system. The main contribution of the work is dynamically adapting the important parameters throughout the execution of the flower pollination algorithm (FPA) using concepts of fuzzy logic. By adapting the main parameters of the metaheuristics, the performance and accuracy of the metaheuristic have been improving in a varied range of applications.Design/methodology/approach: The fuzzy logic-based parameter adaptation in the FPA is proposed. In addition, type-2 fuzzy logic is used to design fuzzy inference system for dynamic parameter adaptation in metaheuristics, which can help in eliminating uncertainty and hence offers an attractive improvement in dynamic parameter adaption in metaheuristic method, and, in reality, the effectiveness of the interval type-2 fuzzy inference system (IT2 FIS) has shown to provide improved results as matched to type-1 fuzzy inference system (T1 FIS) in some latest work.Findings: One case study is considered for testing the proposed approach in a fault tolerant control problem without faults and with partial loss of effectiveness of main actuator fault with abrupt and incipient nature. For comparison between the type-1 fuzzy FPA and interval type-2 fuzzy FPA is presented using statistical analysis which validates the advantages of the interval type-2 fuzzy FPA. The statistical Z-test is presented for comparison of efficiency between two fuzzy variants of the FPA optimization method.Originality/value: The main contribution of the work is a dynamical adaptation of the important parameters throughout the execution of the flower pollination optimization algorithm using concepts of type-2 fuzzy logic. By adapting the main parameters of the metaheuristics, the performance and accuracy of the metaheuristic have been improving in a varied range of applications.