J. Quincy Brown

Dr. J. Quincy Brown


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2020 in medRxiv
Verified
Preprint
Open access
PDF file
SFSharon E. Fox
Sharon E. Fox
AAAibek Akmatbekov
Aibek Akmatbekov
JHJack L. Harbert
Jack L. Harbert
GLGuang Li
Guang Li
JBJ. Quincy Brown
J. Quincy Brown
RHRichard S. Vander Heide
Richard S. Vander Heide
SARS-CoV-2 has rapidly spread across the United States, causing extensive morbidity and mortality, though the histopathologic basis of severe disease cases has yet to be studied in detail. Over the past century, autopsy has contributed significantly to our understanding of numerous disease processes, but for several reasons, autopsy reports following deaths related to SARS- CoV-2 have thus far been limited across the globe. We report on the relevant cardiopulmonary findings in the first series of autopsies in the United States, with the cause of death being due to SARS-CoV-2 infection. These cases identify key pathologic states potentially contributing to severe disease and decompensation in these patients.

4 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PLPeter Lawson
Peter Lawson
ASAndrew B. Sholl
Andrew B. Sholl
JBJ. Quincy Brown
J. Quincy Brown
BFBrittany Terese Fasy
Brittany Terese Fasy
CWCarola Wenk
Carola Wenk
The current system for evaluating prostate cancer architecture is the Gleason grading system which divides the morphology of cancer into five distinct architectural patterns, labeled 1 to 5 in increasing levels of cancer aggressiveness, and generates a score by summing the labels of the two most dominant patterns. The Gleason score is currently the most powerful prognostic predictor of patient outcomes; however, it suffers from problems in reproducibility and consistency due to the high intra-observer and inter-observer variability amongst pathologists. In addition, the Gleason system lacks the granularity to address potentially prognostic architectural features beyond Gleason patterns. We evaluate prostate cancer for architectural subtypes using techniques from topological data analysis applied to prostate cancer glandular architecture. In this work we demonstrate the use of persistent homology to capture architectural features independently of Gleason patterns. Specifically, using persistent homology, we compute topological representations of purely graded prostate cancer histopathology images of Gleason patterns 3,4 and 5, and show that persistent homology is capable of clustering prostate cancer histology into architectural groups through a ranked persistence vector. Our results indicate the ability of persistent homology to cluster prostate cancer histopathology images into unique groups with dominant architectural patterns consistent with the continuum of Gleason patterns. In addition, of particular interest, is the sensitivity of persistent homology to identify specific sub-architectural groups within single Gleason patterns, suggesting that persistent homology could represent a robust quantification method for prostate cancer architecture with higher granularity than the existing semi-quantitative measures. The capability of these topological representations to segregate prostate cancer by architecture makes them an ideal candidate for use as inputs to future machine learning approaches with the intent of augmenting traditional approaches with topological features for improved diagnosis and prognosis.

30 September 2015 in Cancer Research
Verified
Journal Article
Closed access
PDF file
MWMei Wang
Mei Wang
HKHillary Z. Kimbrell
Hillary Z. Kimbrell
ASAndrew B. Sholl
Andrew B. Sholl
DTDavid B. Tulman
David B. Tulman
KEKatherine N. Elfer
Katherine N. Elfer
JBJ. Quincy Brown
J. Quincy Brown
Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced transrectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histologic, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols, such as frozen section analysis (FSA), are destructive and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive nondestructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds and contain excellent contrast and detail, exhibiting close correlation with corresponding hematoxylin and eosin histology. A clinically relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the receiver operative curve (AUC) of 0.82–0.88, with a sensitivity ranging from 63% to 88% and a specificity ranging from 78% to 89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75% to 92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure. Cancer Res; 75(19); 4032–41. ©2015 AACR.

27 October 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KEKatherine N Elfer
Katherine N Elfer
ASAndrew B Sholl
Andrew B Sholl
MWMei Wang
Mei Wang
DTDavid B Tulman
David B Tulman
SMSree H Mandava
Sree H Mandava
JBJ. Quincy Brown
J. Quincy Brown
Real-time on-site histopathology review of biopsy tissues at the point-of-procedure has great potential for significant clinical value and improved patient care. For instance, on-site review can aid in rapid screening of diagnostic biopsies to reduce false-negative results, or in quantitative assessment of biospecimen quality to increase the efficacy of downstream laboratory and histopathology analysis. However, the only currently available rapid pathology method, frozen section analysis (FSA), is too time- and labor-intensive for use in screening large quantities of biopsy tissues and is too destructive for maximum tissue conservation in multiple small needle core biopsies. In this work we demonstrate the spectrally-compatible combination of the nuclear stain DRAQ5 and the anionic counterstain eosin as a dual-component fluorescent staining analog to hematoxylin and eosin intended for use on fresh, unsectioned tissues. Combined with optical sectioning fluorescence microscopy and pseudo-coloring algorithms, DRAQ5 and eosin (“D&E”) enables very fast, non-destructive psuedohistological imaging of tissues at the point-of-acquisition with minimal tissue handling and processing. D&E was validated against H&E on a one-to-one basis on formalin-fixed paraffin-embedded and frozen section tissues of various human organs using standard epi-fluorescence microscopy, demonstrating high fidelity of the staining mechanism as an H&E analog. The method was then applied to fresh, whole 18G renal needle core biopsies and large needle core prostate biospecimen biopsies using fluorescence structured illumination optical sectioning microscopy. We demonstrate the ability to obtain high-resolution histology-like images of unsectioned, fresh tissues similar to subsequent H&E staining of the tissue. The application of D&E does not interfere with subsequent standard-of-care H&E staining and imaging, preserving the integrity of the tissue for thorough downstream analysis. These results indicate that this dual-stain pseudocoloring method could provide a real-time histology-like image at the time of acquisition and valuable objective tissue analysis for the clinician at the time of service.

7 January 2014 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
TSTyler C. Schlichenmeyer
Tyler C. Schlichenmeyer
MWMei Wang
Mei Wang
KEKatherine N. Elfer
Katherine N. Elfer
JBJ. Quincy Brown
J. Quincy Brown
We report the development of a structured illumination microscopy instrument specifically designed for the requirements for high-area-throughput, optically-sectioned imaging of large, fluorescently-stained tissue specimens. The system achieves optical sectioning frame-rates of up to 33 Hz (and pixel sampling rates of up to 138.4 MHz), by combining a fast, ferroelectric spatial light modulator for pattern generation with the latest large-format, high frame-rate scientific CMOS camera technology. Using a 10X 0.45 NA objective and a 7 mm/sec scan stage, we demonstrate 4.4 cm2/min area-throughput rates in bright tissue-simulating phantoms, and 2 cm2/min area-throughput rates in thick, highly-absorbing, fluorescently-stained muscle tissue, with 1.3 μm lateral resolution. We demonstrate high-contrast, high-resolution imaging of a fluorescently-stained 30.4 cm2 bovine muscle specimen in 15 minutes comprising 7.55 gigapixels, demonstrating the feasibility of the approach for gigapixel imaging of large tissues in short timeframes, such as would be needed for intraoperative imaging of tumor resection specimens.

3 June 2016 in Scientific Reports
Verified
Journal Article
Open access
MWMei Wang
Mei Wang
DTDavid B. Tulman
David B. Tulman
ASAndrew B. Sholl
Andrew B. Sholl
HKHillary Z. Kimbrell
Hillary Z. Kimbrell
SMSree H. Mandava
Sree H. Mandava
JBJ. Quincy Brown
J. Quincy Brown
Achieving cancer-free surgical margins in oncologic surgery is critical to reduce the need for additional adjuvant treatments and minimize tumor recurrence; however, there is a delicate balance between completeness of tumor removal and preservation of adjacent tissues critical for normal post-operative function. We sought to establish the feasibility of video-rate structured illumination microscopy (VR-SIM) of the intact removed tumor surface as a practical and non-destructive alternative to intra-operative frozen section pathology, using prostate cancer as an initial target. We present the first images of the intact human prostate surface obtained with pathologically-relevant contrast and subcellular detail, obtained in 24 radical prostatectomy specimens immediately after excision. We demonstrate that it is feasible to routinely image the full prostate circumference, generating gigapixel panorama images of the surface that are readily interpreted by pathologists. VR-SIM confirmed detection of positive surgical margins in 3 out of 4 prostates with pathology-confirmed adenocarcinoma at the circumferential surgical margin, and furthermore detected extensive residual cancer at the circumferential margin in a case post-operatively classified by histopathology as having negative surgical margins. Our results suggest that the increased surface coverage of VR-SIM could also provide added value for detection and characterization of positive surgical margins over traditional histopathology.