Kaywan Izadpanah

Dr. Kaywan Izadpanah

Department of Orthopedics and Traumatology, University of Freiburg, Freiburg, Germany
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2013 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
EWElisabeth Weitzel
Elisabeth Weitzel
MVMarco Vicari
Marco Vicari
JHJürgen Hennig
Jürgen Hennig
MWMatthias Weigel
Matthias Weigel
PNPhilipp Niemeyer
Philipp Niemeyer

1 May 2009 in Spine
Verified
Journal Article
Closed access
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
GKGerhard Konrad
Gerhard Konrad
NSNorbert P. Südkamp
Norbert P. Südkamp
MOMichael Oberst
Michael Oberst
Comparison of the dose area product (DAP), the radiation time and the operation time during computer navigated and conventional balloon kyphoplasty procedures. To compare the patients radiation exposure and operation time in a balloon kyphoplasty procedure with and without using a navigation system for the placement of working needles. Minimal invasive spine surgery is associated with high radiation exposure for both the patient and the surgeon. The use of computer navigation has led to a reduced radiation exposure in experimental trials. To our knowledge, there is no clinical data determining the influence of computer navigation on radiation exposure and operation time in a balloon kyphoplasty procedure. Twenty-nine patients with 30 osteoporotic vertebra fractures were treated with a computer-navigated kyphoplasty. The placement of the working needles in thoracic spine fractures was performed after acquiring an intraoperative three-dimensional data set. Fractures of the lumbar spine were treated using fluoroscopic three-dimensional navigation. During each procedure the operation time, the overall radiation time, and the DAP were documented. The data of the navigated operations were compared to a control group of consisting of 30 conventional balloon kyphoplasty procedures. In the conventional kyphoplasty group the average operation times for thoracic spine (ts) and lumbar spine (ls) were 61 and 57 minutes, respectively. The average radiation times were 175 and 165 seconds. The DAP applied to the patient was 1972 and 2105 cGy cm. The average operation times in the navigated group were 67 minutes in the ts and 62 minutes in the ls. The average radiation time was reduced significantly in the navigated group (99 seconds ts and 74 seconds ls). The DAP applied to the patient was also significantly lower (1245 cGy cm (ts) and 1318 cGy cm (ls)). The use of computer navigation systems in balloon kyphoplasty procedures reduces the radiation exposure of patients and surgeons significantly. The increased technical effort did not lead to a significant longer operation time. Hence, the use of computer navigation systems in balloon kyphoplasty procedures is recommended.

21 December 2018 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
AFAndreas Fuchs
Andreas Fuchs
FKFerdinand Kloos
Ferdinand Kloos
GBGerrit Bode
Gerrit Bode
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
NSNorbert P. Südkamp
Norbert P. Südkamp
MFMatthias J. Feucht
Matthias J. Feucht
Failure of isolated primary meniscal repair must be expected in approximately 10–25% of cases. Patients requiring revision surgery may benefit from revision meniscal repair, however, the results of this procedure remain underreported. The purpose of this study was therefore to evaluate the outcome and failure rates of isolated revision meniscal repair in patients with re-tears or failed healing after previous meniscal repair in stable knee joints. A chart review was performed to identify all patients undergoing revision meniscal repair between 08/2010 and 02/2016. Only patients without concomitant procedures, without ligamentous insufficiency, and a minimum follow-up of 24 months were included. The records of all patients were reviewed to collect patient demographics, injury patterns of the meniscus, and details about primary and revision surgery. Follow-up evaluation included failure rates, clinical outcome scores (Lysholm Score, KOOS Score), sporting activity (Tegner scale), and patient satisfaction. A total of 12 patients with a mean age of 22 ± 5 years were included. The mean time between primary repair and revision repair was 27 ± 21 months. Reasons for failed primary repairs were traumatic re-tears in 10 patients (83%) and failed healing in two patients (17%). The mean follow-up period after revision meniscal repair was 43 (± 23.4) months. Failure of revision meniscal repair occurred in 3 patients (25%). In two of these patients, successful re-revision repair was performed. At final follow-up, the mean Lysholm Score was 95.2 (± 4.2) with a range of 90–100, representing a good to excellent result in all patients. The final assessment of the KOOS subscores also showed good to excellent results. The mean Tegner scale was 6.8 ± 1.8, indicating a relatively high level of sports participation. Ten patients (83%) were either satisfied or very satisfied with the outcome. In patients with re-tears or failed healing after previous isolated meniscal repair, revision meniscal repair results in good to excellent knee function, high level of sports participation, and high patient satisfaction. The failure rate is slightly higher compared to isolated primary meniscal repair, but still acceptable. Therefore, revision meniscal repair is worthwhile in selected cases in order to save as much meniscal tissue as possible.

6 September 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
DMDirk Maier
Dirk Maier
MJmartin Jaeger
martin Jaeger
KRKilian Reising
Kilian Reising
MFMatthias J. Feucht
Matthias J. Feucht
NSNorbert P. Südkamp
Norbert P. Südkamp
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
Horizontal instability impairs clinical outcome following acute acromioclavicular joint (ACJ) reconstruction and may be caused by insufficient healing of the superior acromioclavicular ligament complex (ACLC). However, characteristics of acute ACLC injuries are poorly understood so far. Purposes of this study were to identify different ACLC tear types, assess type-specific prevalence and determine influencing cofactors. This prospective, cross-sectional study comprised 65 patients with acute-traumatic Rockwood-5 (n = 57) and Rockwood-4 (n = 8) injuries treated operatively by means of mini-open ACJ reduction and hook plate stabilization. Mean age at surgery was 38.2 years (range, 19–57 years). Standardized pre- and intraoperative evaluation included assessment of ACLC tear patterns and cofactors related to the articular disc, the deltoid-trapezoidal (DT) fascia and bony ACJ morphology. Articular disc size was quantified as 0 = absent, 1 = remnant, 2 = meniscoid and 3 = complete. All patients showed complete ruptures of the superior ACLC, which could be assigned to four different tear patterns. Clavicular-sided (AC-1) tears were observed in 46/65 (70.8 %), oblique (AC-2) tears in 12/65 (18.5 %), midportion (AC-3) tears in 3/65 (4.6 %) and acromial-sided (AC-4) tears in 4/65 (6.1 %) of cases. Articular disc size manifestation was significantly (P < .001) more pronounced in patients with AC-1 tears (1.89 ± 0.57) compared to patients with AC-2 tears (0.67 ± 0.89). Other cofactors did not influence ACLC tear patterns. ACLC dislocation with incarceration caused mechanical impediment to anatomical ACJ reduction in 14/65 (21.5 %) of cases including all Rockwood-4 dislocations. Avulsion “in continuity” was a consistent mode of failure of the DT fascia. Type-specific operative strategies enabled anatomical ACLC repair of all observed tear types. Acute ACLC injuries follow distinct tear patterns. There exist clavicular-sided (AC-1), oblique (AC-2), midportion (AC-3) and acromial-sided (AC-4) tears. Articular disc size was a determinant factor of ACLC tear morphology. Mini-open surgery was required in Rockwood-4 and a relevant proportion of Rockwood-5 dislocations to achieve both anatomical ACLC and ACJ reduction. Type-specific operative repair of acute ACLC tears might promote biological healing and lower rates of horizontal ACJ instability following acute ACJ reconstruction.

13 April 2015 in Arthroscopy Techniques
Verified
Journal Article
Open access
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
MJmartin Jaeger
martin Jaeger
POPeter Ogon
Peter Ogon
NSNorbert P. Südkamp
Norbert P. Südkamp
DMDirk Maier
Dirk Maier
An arthroscopically assisted technique for the treatment of acute acromioclavicular joint dislocations is presented. This pathology‐based procedure aims to achieve anatomic healing of both the acromioclavicular ligament complex (ACLC) and the coracoclavicular ligaments. First, the acromioclavicular joint is reduced anatomically under macroscopic and radiologic control and temporarily transfixed with a K‐wire. A single‐channel technique using 2 suture tapes provides secure coracoclavicular stabilization. The key step of the procedure consists of the anatomic repair of the ACLC (“AC‐Reco”). Basically, we have observed 4 patterns of injury: clavicular‐sided, acromial‐sided, oblique, and midportion tears. Direct and/or transosseous ACLC repair is performed accordingly. Then, an X‐configured acromioclavicular suture tape cerclage (“AC‐Bridge”) is applied under arthroscopic assistance to limit horizontal clavicular translation to a physiological extent. The AC‐Bridge follows the principle of internal bracing and protects healing of the ACLC repair. The AC‐Bridge is tightened on top of the repair, creating an additional suture‐bridge effect and promoting anatomic ACLC healing. We refer to this combined technique of anatomic ACLC repair and protective internal bracing as the “AC‐RecoBridge.” A detailed stepwise description of the surgical technique, including indications, technical pearls and pitfalls, and potential complications, is given. Technique Video: video See video under supplementary data.

22 March 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
DKD. Kubosch
D. Kubosch
JKJohanna Kubosch
Johanna Kubosch
Boyko GueorguievBoyko Gueorguiev
Boyko Gueorguiev
IZIvan Zderic
Ivan Zderic
MWMarkus Windolf
Markus Windolf
PSP. C. Strohm
P. C. Strohm
Although minimally invasive posterior spine implant systems have been introduced, clinical studies reported on reduced quality of spinal column realignment due to correction loss. The aim of this study was to compare biomechanically two minimally invasive spine stabilization systems versus the Universal Spine Stabilization system (USS). Three groups with 5 specimens each and 2 foam bars per specimen were instrumented with USS (Group 1) or a minimally invasive posterior spine stabilization system with either polyaxial (Group 2) or monoaxial (Group 3) screws. Mechanical testing was performed under quasi-static ramp loading in axial compression and torsion, followed by destructive cyclic loading run under axial compression at constant amplitude and then with progressively increasing amplitude until construct failure. Bending construct stiffness, torsional stiffness and cycles to failure were investigated. Initial bending stiffness was highest in Group 3, followed by Group 2 and Group 1, without any significant differences between the groups. A significant increase in bending stiffness after 20’000 cycles was observed in Group 1 (p = 0.002) and Group 2 (p = 0.001), but not in Group 3, though the secondary bending stiffness showed no significant differences between the groups. Initial and secondary torsional stiffness was highest in Group 1, followed by Group 3 and Group 2, with significant differences between all groups (p ≤ 0.047). A significant increase in initial torsional stiffness after 20’000 cycles was observed in Group 2 (p = 0.017) and 3 (p = 0.013), but not in Group 1. The highest number of cycles to failure was detected in Group 1, followed by Group 3 and Group 2. This parameter was significantly different between Group 1 and Group 2 (p = 0.001), between Group 2 and Group 3 (p = 0.002), but not between Group 1 and Group 3. These findings quantify the correction loss for minimally invasive spine implant systems and imply that unstable spine fractures might benefit from stabilization with conventional implants like the USS.