Due to the complicated engineering operation of the check valve in a high−pressure diaphragm pump, its vibration signal tends to show non−stationary and non−linear characteristics. These leads to difficulty extracting fault features and, hence, a low accuracy for fault diagnosis. It is difficult to extract fault features accurately and reliably using the traditional MPE method, and the ELM model has a low accuracy rate in fault classification. Multi−scale weighted permutation entropy (MWPE) is based on extracting multi−scale fault features and arrangement pattern features, and due to the combination of extracting a sequence of amplitude features, fault features are significantly enhanced, which overcomes the deficiency of the single−scale permutation entropy characterizing the complexity of vibration signals. It establishes the check valve fault diagnosis model from the twin extreme learning machine (TELM). The TELM fault diagnosis model established, based on MWPE, aims to find a pair of non−parallel classification hyperplanes in the equipment state space to improve the model’s applicability. Experiments show that the proposed method effectively extracts the characteristics of the vibration signal, and the fault diagnosis model effectively identifies the fault state of the check valve with an accuracy rate of 97.222%.
The check valve is the core part of high-pressure diaphragm pumps. It has complex operation conditions and has difficulty characterizing fault states completely with its single feature. Therefore, a fault signal diagnosis model based on the kernel extreme learning machine (KELM) was constructed to diagnose the check valve. The model adopts a multi-feature extraction method and reduces dimensionality through kernel partial least squares (KPLS). Firstly, we divided the check valve vibration signal into several non-overlapping samples. Then, we extracted 16 time-domain features, 13 frequency-domain features, 16 wavelet packet energy features, and energy entropy features from each sample to construct a multi-feature set characterizing the operation state of the check valve. Next, we used the KPLS method to optimize the 45 dimension multi-feature data and employed the processed feature set to establish a KELM fault diagnosis model. Experiments showed that the method based on KPLS optimal feature selection could fully characterize the operating state of the equipment with an accuracy rate of 96.88%. This result indicates the high accuracy and effectiveness of the multi-feature set constructed with the KELM fault diagnosis model.