The novel use of magnetic force to optimize modern surgical techniques originated in the 1970s. Since then, magnets have been utilized as an adjunct or alternative to a wide array of existing surgical procedures, ranging from gastrointestinal to vascular surgery. As the use of magnets in surgery continues to grow, the body of knowledge on magnetic surgical devices from preclinical development to clinical implementation has expanded significantly; however, the current magnetic surgical devices can be organized based on their core function: serving as a guidance system, creating a new connection, recreating a physiologic function, or utilization of an internal–external paired magnet system. The purpose of this article is to discuss the biomedical considerations during magnetic device development and review the current surgical applications of magnetic devices.
Purpose: Pilonidal disease (PD) is marked by chronic inflammation and frequent recurrence which can decrease quality of life. However, debate remains regarding the optimal treatment for PD in the pediatric population. This study compares two recommended treatment approaches—excision with off-midline flap reconstruction (OMF: Bascom cleft lift flap, modified Limberg flap) and minimally invasive endoscopic pilonidal sinus treatment (EPSiT). Methods: Single-center retrospective evaluation of patients 1–21 years of age with PD who underwent either excision with OMF reconstruction or EPSiT between 10/1/2011 and 10/31/2021. Outcomes included were disease recurrence, reoperation, and wound complication rates. Comparisons were performed using Chi-square and Mann–Whitney U tests. Results: 18 patients underwent excision/OMF reconstruction and 45 patients underwent EPSiT. The excision/OMF reconstruction cohort was predominantly male (44.4% vs 17.8% p = 0.028), with history of prior pilonidal infection (33.3% vs 6.7%; p = 0.006), and longer median operative time (60 min vs 17 min; p < 0.001). The excision/OMF reconstruction cohort had a higher rate of wound complications (22.2% vs 0%; p = 0.001), but lower rates of disease recurrence (5.6% vs 33.3%; p = 0.022) and reoperation (5.6% vs 31.1%; p = 0.031). Conclusion: In pediatric patients with PD, excision with OMF reconstruction may decrease recurrence and reoperation rates with increased operative times and wound complication rates, compared to EPSiT.
Background: Sentinel lymph node (SLN) biopsy is a critical staging tool in skin and soft tissue cancers. Although technetium lymphoscintigraphy is the most common adjunct, indocyanine green (ICG) demonstrates a promising alternative in pediatric, adolescent, and young adult (AYA) skin and soft tissue cancers. Methods and Objectives: Evaluate the safety and efficacy of ICG in SLN biopsy (SLNB) in diverse pediatric and AYA solid cancers in a multi‐institutional environment. This is a prospective, observational study conducted at 13 member institutions in the Pediatric Surgical Oncology Research Collaborative between 2019 and 2023. Eligible patients underwent SLNB for primary or recurrent solid skin and soft tissue tumors. Peritumoral ICG was administered intraoperatively. Outcomes included SLN detection rates, histopathology of excised specimens, and surgeon‐reported assessment of utility. Safety was assessed through adverse event reporting. Results: Forty SLNB procedures yielded 84 specimens: 13 melanoma (32.5%), 12 squamous cell carcinoma (30%), 11 non‐rhabdomyosarcoma soft tissue sarcoma (27.5%), two rhabdomyosarcoma (5%), one Ewing sarcoma (2.5%), and one malignant peripheral nerve sheath tumor (2.5%). Histologic evaluation identified 81 lymph nodes, 75 benign (89.3%) and six malignant (7.1%); three specimens were adipose tissue (3.6%). Of 81 lymph nodes, 76% were ICG‐positive. ICG had a sensitivity of 79.5%, a specificity of 33%, and a positive predictive value of 96%. All malignant nodes were ICG‐avid. There were no adverse reactions to ICG at 30 days. Conclusions: ICG is a safe and effective adjunct for SLNB in pediatric and AYA soft tissue and skin malignancies.