Multi-frequency electrical impedance tomography (mfEIT) offers a nondestructive imaging technology that reconstructs the distribution of electrical characteristics within a subject based on the impedance spectral differences among biological tissues. However, the technology faces challenges in imaging multi-class lesion targets when the conductivity of background tissues is frequency-dependent. To address these issues, we propose a spatial-frequency cross-fusion network (SFCF-Net) imaging algorithm, built on a multi-path fusion structure. This algorithm uses multi-path structures and hyper-dense connections to capture both spatial and frequency correlations between multi-frequency conductivity images, which achieves differential imaging for lesion targets of multiple categories through cross-fusion of information. According to both simulation and physical experiment results, the proposed SFCF-Net algorithm shows an excellent performance in terms of lesion imaging and category discrimination compared to the weighted frequency-difference, U-Net, and MMV-Net algorithms. The proposed algorithm enhances the ability of mfEIT to simultaneously obtain both structural and spectral information from the tissue being examined and improves the accuracy and reliability of mfEIT, opening new avenues for its application in clinical diagnostics and treatment monitoring.
7 April 2023 in IEEE Journal of Biomedical and Health Informatics
Electrical impedance tomography (EIT) is a noninvasive and radiation-free imaging method. As a “soft-field” imaging technique, in EIT, the target signal in the center of the measured field is frequently swamped by the target signal at the edge, which restricts its further application. To alleviate this problem, this study presents an enhanced encoder–decoder (EED) method with an atrous spatial pyramid pooling (ASPP) module. The proposed method enhances the ability to detect central weak targets by constructing an ASPP module that integrates multiscale information in the encoder. The multilevel semantic features are fused in the decoder to improve the boundary reconstruction accuracy of the center target. The average absolute error of the imaging results by the EED method reduced by 82.0%, 83.6%, and 36.5% in simulation experiments and 83.0%, 83.2%, and 36.1% in physical experiments compared with the errors of the damped least-squares algorithm, Kalman filtering method, and U-Net-based imaging method, respectively. The average structural similarity improved by 37.3%, 42.9%, and 3.6%, and 39.2%, 45.2%, and 3.8% in the simulation and physical experiments, respectively. The proposed method provides a practical and reliable means of extending the application of EIT by solving the problem of weak central target reconstruction under the effect of strong edge targets in EIT.
Objective . Traditional magnetic induction tomography (MIT) algorithms have problems in reconstruction, such as large area error (AE), blurred boundaries of reconstructed targets, and considerable image noise (IN). As the size and boundary of a lesion greatly affect the treatment plan, more accurate algorithms are necessary to meet clinical needs. Approach . In this study, adaptive threshold split Bregman (ATSB) is proposed for brain injury monitoring imaging in MIT. We established a 3D brain MIT simulation model with the actual anatomical structure and a phantom model and obtained the reconstructed images of single targets in different positions and multiple targets, using the Tikhonov, eigenvalue threshold regularisation (ETR), split Bregman (SB), and ATSB algorithms. Main results . Compared with the Tikhonov and ETR algorithms, the ATSB algorithm reduced the AE by 95% and the IN by 17% in a simulation and reduced the AE by 87% and IN by 6% in phantom experiments. Compared with the SB algorithm, the ATSB algorithm can reduce the difficulty of adjusting parameters and is easier to use in clinical practice. The simulation and phantom experiments results showed that the ATSB algorithm could reconstruct the target size more accurately and could distinguish multiple targets more effectively than the other three algorithms. Significance . The ATSB algorithm could improve the image quality of MIT and better meet the needs of clinical applications and is expected to promote brain injury monitoring imaging via MIT.
6 June 2022 in IEEE Transactions on Instrumentation and Measurement
Magnetic induction tomography (MIT) is viewed as a promising method for brain imaging. Most MIT studies are based on time-difference imaging, which cannot be used for detecting hemorrhagic stroke. However, for many years, multifrequency MIT (mfMIT) has been proposed for the early detection of hemorrhagic stroke, but the focus has primarily been on theoretical analysis and simulations. mfMIT has not been applied in clinical research due to issues such as inadequate imaging algorithms and mfMIT systems. A weighted frequency difference adaptive thresholding split Bregman (WFD–ATSB) algorithm is proposed here and is validated for the first time using a 16-channel mfMIT system developed by our group. The imaging results of a single-hemorrhagic model were evaluated using the total image reconstruction error [as the sum of the position error, area error, and image noise (IN)], and the imaging results of a double-hemorrhagic model were evaluated by calculating the correlation coefficient (CC). Simulation results showed that WFD–ATSB can reduce the overall image reconstruction error by 52% and improve the CC by 35% compared with that of the traditional algorithm. In phantom experiments, the total image reconstruction error was reduced by 27% and the CC was improved by 15%. The results confirmed that WFD–ATSB is a more practical and stable algorithm for mfMIT compared with traditional methods, which is promising for the rapid detection of cerebral hemorrhage.
Electrical impedance tomography (EIT) is low-cost and noninvasive and has the potential for real-time imaging and bedside monitoring of brain injury. However, brain injury monitoring by EIT imaging suffers from image noise (IN) and resolution problems, causing blurred reconstructions. To address these problems, a least absolute shrinkage and selection operator model is built, and a fast iterative shrinkage-thresholding algorithm with continuation (FISTA-C) is proposed. Results of numerical simulations and head phantom experiments indicate that FISTA-C reduces IN by 63.2%, 47.2%, and 29.9% and 54.4%, 44.7%, and 22.7%, respectively, when compared with the damped least-squares algorithm, the split Bergman, and the FISTA algorithms. When the signal-to-noise ratio of the measurements is 80–50 dB, FISTA-C can reduce IN by 83.3%, 72.3%, and 68.7% on average when compared with the three algorithms, respectively. Both simulation and phantom experiments suggest that FISTA-C produces the best image resolution and can identify the two closest targets. Moreover, FISTA-C is more practical for clinical application because it does not require excessive parameter adjustments. This technology can provide better reconstruction performance and significantly outperforms the traditional algorithms in terms of IN and resolution and is expected to offer a general algorithm for brain injury monitoring imaging via EIT.
Electrical impedance tomography (EIT) is a noninvasive functional diagnostic technique that has been successfully applied to human lung and brain. EIT reconstruction is an ill-conditioned problem: the regularization parameters establish a trade-off between acceptable data fitting and acceptable solution stability. This trade-off is necessary to select the optimal regularization parameters for each data frame to continuously obtain high-quality images in real-time monitoring. However, using the objective regularization parameter selection method before each image reconstruction may reduce the reconstruction efficiency, and using heuristic selection for all images may cause significant quality degradation, thereby creating challenges in long-term clinical EIT monitoring. This study explores a robust EIT target adaptive differential iterative reconstruction algorithm that does not require the advance selection of the optimal regularization parameter to facilitate the clinical application of EIT long-term bedside monitoring. Specifically, second-order Taylor approximation expansion and Euler–Lagrange theorem were used to derive the conductivity differential iteration relationship. Furthermore, the reconstruction quality and generalization ability of the proposed algorithm were validated based on comparisons with the L-curve and the generalized cross-validation parameter selection methods through simulations, phantom experiments, and human lung recruitment data. Compared with the L-curve and generalized cross-validation methods, the TADI algorithm reduces the position error by 33.07% and 47.17%, the ringing by 26.49% and 32.69%, and the shape deformation by 18.34% and 19.40% on average, respectively. The results revealed that the TADI algorithm could achieve a significant improvement over the existing state-of-the-art methods in terms of stability, consistency, and efficiency.