William O’Brien

Mr. William O’Brien

Electronic & Computer Engineering, University of Limerick, Limerick, Ireland
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MNMd Noor-A-Rahim
Md Noor-A-Rahim
JJJobish John
Jobish John
FFFadhil Firyaguna
Fadhil Firyaguna
Hafiz Husnain Raza SheraziHafiz Husnain Raza Sherazi
Hafiz Husnain Raza Sherazi
SKSergii Kushch
Sergii Kushch
EAEddie Armstrong
Eddie Armstrong
Smart manufacturing is a vision and major driver for change in today’s industry. The goal of smart manufacturing is to optimize manufacturing processes through constantly monitoring, controlling, and adapting processes towards more efficient and personalised manufacturing. This requires and relies on technologies for connected machines incorporating a variety of computation, sensing, actuation, and machine to machine communications modalities. As such, understanding the change towards smart manufacturing requires knowledge of the enabling technologies, their applications in real world scenarios and the communication protocols and their performance to meet application requirements. Particularly, wireless communication is becoming an integral part of modern smart manufacturing and is expected to play an important role in achieving the goals of smart manufacturing. This paper presents an extensive review of wireless communication protocols currently applied in manufacturing environments and provides a comprehensive review of the associated use cases whilst defining their expected impact on the future of smart manufacturing. Based on the review, we point out a number of open challenges and directions for future research in wireless communication technologies for smart manufacturing.

11 May 2023 in Telecom
Verified
Journal Article
Open access
PDF file
EOEoin O'Connell
Eoin O'Connell
WOWilliam O’Brien
William O’Brien
MBMangolika Bhattacharya
Mangolika Bhattacharya
DMDenis Moore
Denis Moore
MPMihai Penica
Mihai Penica
As Industry 4.0 networks continue to evolve at a rapid pace, they are becoming increasingly complex and distributed. These networks incorporate a range of technologies that are integrated into smart manufacturing systems, requiring adaptability, security, and resilience. However, managing the complexity of Industry 4.0 networks presents significant challenges, particularly in terms of security and the integration of diverse technologies into a functioning and efficient infrastructure. To address these challenges, emerging digital twin standards are enabling the connection of various systems by linking individual digital twins, creating a system of systems. The objective is to develop a “universal translator” that can interpret inputs from both the real and digital worlds, merging them into a seamless cyber-physical reality. It will be demonstrated how the myriad of technologies and systems in Industry 4.0 networks can be connected through the use of digital twins to create a seamless “system of systems”. This will improve interoperability, resilience, and security in smart manufacturing systems. The paper will also outline the potential benefits and limitations of digital twins in addressing the challenges of Industry 4.0 networks.

6 September 2025 in Computer Networks
Verified
Journal Article
Open access
WOWilliam O’Brien
William O’Brien
ADAdam Dooley
Adam Dooley
MPMihai Penica
Mihai Penica
DMDenis Moore
Denis Moore
EOEoin O'Connell
Eoin O'Connell

Verified
Journal Article
Open access
PDF file
WOWilliam O’Brien
William O’Brien
ADAdam Dooley
Adam Dooley
MPMihai Penica
Mihai Penica
SMSean McGrath
Sean McGrath
EOEoin O'Connell
Eoin O'Connell
Wireless connectivity plays a pivotal role in enabling real-time telemetry, sensor feedback, and autonomous navigation within Industry 4.0 environments. This paper presents a ROS 2-based mobile robotic platform designed to perform real-time network diagnostics across both private 5G and Wi-Fi technologies in a live smart manufacturing testbed. The system integrates high-frequency telemetry acquisition with spatial localization, multi-protocol connection analysis, and detailed performance monitoring. Metrics such as latency, packet loss, bandwidth, and IIoT (Industrial Internet of Things) data stream health are continuously logged and analysed. Telemetry is captured during motion and synchronously stored in an InfluxDB time-series database, enabling live visualization through Grafana dashboards. A key feature of the platform is its dual-path transmission architecture, which provides communication redundancy and allows side-by-side evaluation of network behaviour under identical physical conditions. Experimental trials demonstrate the platform’s ability to detect roaming events, characterize packet loss, and reveal latency differences between Wi-Fi and 5G networks. Results show that Wi-Fi suffered from roaming-induced instability and packet loss, whereas 5G maintained stable and uninterrupted connectivity throughout the test area. This work introduces a modular, extensible framework for mobile network evaluation in industrial settings and provides practical insights for infrastructure tuning, protocol selection, and wireless fault detection.

23 April 2026 in IEEE Access
Verified
Journal Article
Open access
WOWilliam O’Brien
William O’Brien
ADAdam Dooley
Adam Dooley
MPMihai Penica
Mihai Penica
SMSean McGrath
Sean McGrath
EOEoin O'Connell
Eoin O'Connell
The transition toward fully wireless industrial automation under Industry 4.0 requires communication systems capable of deterministic and ultra-reliable performance. This study experimentally evaluates the potential of multi-connectivity, specifically the simultaneous use of private 5G, public 5G/LTE, and Wi-Fi in order to meet the 99.9% reliability target defined in 3GPP TS 22.104 for mission-critical applications. Using a mobile robotic platform within the Confirm Smart Manufacturing Centre, four experimental scenarios were conducted under stationary and mobile conditions with 64 byte and 25000 byte payloads. Results show that no individual interface achieved the 99.9% reliability threshold independently, however composite multi-path configurations employing packet duplication across interfaces consistently met or exceeded this benchmark, achieving up to 100% reliability. Dual private 5G + Wi-Fi and triple-interface configurations eliminated single-path deficiencies, while private 5G demonstrated superior stability under mobility due to its single cell architecture. Although packet duplication increases overall network load, it ensures mission-critical communication with a minimum reliability of 99.98%, fulfilling deterministic performance requirements for industrial control and robotic systems. These findings confirm that multi-connectivity offers a practical and robust approach to achieving ultra-reliable wireless communication in industrial environments.