Stuart Smith

Dr. Stuart Smith

Center for Precision Metrology & Department of Physics and Optical Science, University of North Carolina, Charlotte, NC 28223, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Acta Biomaterialia
Verified
Journal Article
Open access
RSRene B. Svensson
Rene B. Svensson
Stuart SmithStuart Smith
Stuart Smith
PMPatrick J. Moyer
Patrick J. Moyer
SMS. Peter Magnusson
S. Peter Magnusson
Connective tissues are ubiquitous throughout the body and consequently affect the function of many organs. In load bearing connective tissues like tendon, the mechanical functionality is provided almost exclusively by collagen fibrils that in turn are stabilized by covalent cross-links. Functionally distinct tendons display different cross-link patterns, which also change with maturation, but these differences have not been studied in detail at the fibril level. In the present study, a custom built nanomechanical test platform was designed and fabricated to measure tensile mechanics of individual fibrils from rat tendons. The influence of animal maturity (4 vs. 16 week old rats) and functionally different tendons (tail vs. Achilles tendons) were examined. Additionally the effect of methylglyoxal (MG) treatment in vitro to form advanced glycation end products (AGEs) was investigated. Age and tissue type had no significant effect on fibril mechanics, but MG treatment increased strength and stiffness without inducing brittleness and gave rise to a distinct three-phase mechanical response corroborating that previously reported in human patellar tendon fibrils. That age and tissue had little mechanical effect, tentatively suggest that variations in enzymatic cross-links may play a minor role after initial tissue formation. Tendons are connective tissues that connect muscle to bone and carry some of the greatest mechanical loads in the body, which makes them common sites of injury. A tendon is essentially a biological rope formed by thin strands called fibrils made of the protein collagen. Tendon function relies on the strength of these fibrils, which in turn depends on naturally occurring cross-links between collagen molecules, but the mechanical influence of these cross-links have not been measured before. It is believed that beneficial cross-linking occurs with maturation while additional cross-linking with aging may lead to brittleness, but this study provides evidence that maturation has little effect on mechanical function and that age-related cross-linking does not result in brittle collagen fibrils.

1 January 2022 in Precision Engineering
Verified
Journal Article
Closed access
HVHerminso Villarraga-Gómez
Herminso Villarraga-Gómez
Stuart SmithStuart Smith
Stuart Smith

1 November 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
BNB. K. Nowakowski
B. K. Nowakowski
DSD. T. Smith
D. T. Smith
Stuart SmithStuart Smith
Stuart Smith
This paper presents the design, construction, and characterization of a new optical-fiber-based, low-finesse Fabry-Perot interferometer with a simple cavity formed by two reflecting surfaces (the end of a cleaved optical fiber and a plane, reflecting counter-surface), for the continuous measurement of displacements of several nanometers to several tens of millimeters. No beam collimation or focusing optics are required, resulting in a displacement sensor that is extremely compact (optical fiber diameter 125 μm), is surprisingly tolerant of misalignment (more than 5°), and can be used over a very wide range of temperatures and environmental conditions, including ultra-high-vacuum. The displacement measurement is derived from interferometric phase measurements using an infrared laser source whose wavelength is modulated sinusoidally at a frequency f. The phase signal is in turn derived from changes in the amplitudes of demodulated signals, at both the modulation frequency, f, and its harmonic at 2f, coming from a photodetector that is monitoring light intensity reflected back from the cavity as the cavity length changes. Simple quadrature detection results in phase errors corresponding to displacement errors of up to 25 nm, but by using compensation algorithms discussed in this paper, these inherent non-linearities can be reduced to below 3 nm. In addition, wavelength sweep capability enables measurement of the absolute surface separation. This experimental design creates a unique set of displacement measuring capabilities not previously combined in a single interferometer.

26 October 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
JCJacob W Chesna
Jacob W Chesna
BWBob F Wiedmaier
Bob F Wiedmaier
JWJinlin Wang
Jinlin Wang
ASAyman Samara
Ayman Samara
Richard LeachRichard Leach
Richard Leach
Stuart SmithStuart Smith
Stuart Smith
A method is presented in which the wetting contact angle of a sessile drop is acquired aerially using confocal techniques to measure the radius and the height of a droplet deposited on a planar surface. The repeatability of this method is typically less than 0.25°, and often less than 0.1°, for droplet diameters less than 1 mm. To evaluate accuracy of this method, an instrument uncertainty budget is developed, which predicts a combined uncertainty of 0.91° for a 1 mm diameter water droplet with a contact angle of 110°. For droplets having diameters less than 1 mm and contact angles between 15° and 160°, these droplets approach spherical shape and their contact angles can be computed analytically with less than 1% error. For larger droplets, gravitational deformation needs to be considered.

10 October 2022 in Precision Engineering
Verified
Journal Article
Closed access
HVHerminso Villarraga-Gómez
Herminso Villarraga-Gómez
EMEdward P. Morse
Edward P. Morse
Stuart SmithStuart Smith
Stuart Smith

1 May 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MAMasoud Arablu
Masoud Arablu
Stuart SmithStuart Smith
Stuart Smith
A radio-frequency Frequency-Modulated (FM) signal is used to diffract a He-Ne laser beam through an Acousto-Optic Modulator (AOM). Due to the modulation of the FM signal, the measured spectra of the diffracted beams comprise a series of phase-synchronized harmonics that have exact integer frequency separation. The first diffraction side-beam emerging from the AOM is selected by a slit to be used in a polydyne displacement interferometer in a Michelson interferometer topology. The displacement measurement is derived from the phase measurement of selected modulation harmonic pairs. Individual harmonic frequency amplitudes are measured using discrete Fourier transform applied to the signal from a single photodetector. Phase signals are derived from the changes in the amplitudes of different harmonic pairs (typically odd-even pairs) with the phase being extracted using a standard quadrature method. In this study, two different modulation frequencies of 5 and 10 kHz are used at different modulation depths. The measured displacements by different harmonic pairs are compared with a commercial heterodyne interferometer being used as a reference for these studies. Measurements obtained from five different harmonic pairs when the moving mirror of the interferometer is scanned over ranges up to 10 μm all show differences of less than 50 nm from the reference interferometer measurements. A drift test was also used to evaluate the differences between the polydyne interferometer and reference measurements that had different optical path lengths of approximately 25 mm and 50 mm, respectively. The drift test results indicate that about half of the differences can be attributed to temperature, pressure, and humidity variations. Other influences include Abbe and thermal expansion effects. Rough magnitude estimates using simple models for these two effects can account for remaining observed deviations.