Land use as representation of human activities had different type. Human activity needs land for home, food, school, work, and leisure. Land use changed depends on human activity in the world within spatial and temporal term. This study aims to identify land use change using Google Earth data spatially and temporally. To answer the aim of this research, Google Earth data within five-year used for the analysis. This technique use for detection and mapping the land use change. The result saw the spatial-temporal land use change each year. This result addressed very importance of Google Earth Data as spatial temporal land use detection for land use mapping.
As education area, campus or university is full with various activities which have an impact on the existence of land-use or land-cover. The variation of activities dynamically change the shape of land-use or land-cover within the campus area, thus also create variations in Land Surface Temperature (LST). The LST are impacting the coziness of human activity especially when reaches more than 30 oC. This study used the term Urban Heat Signature (UHS) to explain LST in different land-use or land-cover types. The objective of this study is to examine UHS as an Urban Heat Hazard (UHH) based on Universal Temperature Climate Index (UTCI) and Effective Temperature Index (ETI) in University of Indonesia. Thermal bands of Landsat 8 images (the acquisition year 2013-2015) were used to create LST model. A ground data known as Air Surface Temperature (AST) were used to validate the model. The result showed an increased level of maximum temperature during September-October since 2013 until 2014. The maximum temperature was reduced in October 2014, however it increased again in August 2015. The UTCI showed “moderate” and “strong heat stress”, while EFI showed “uncomfortable” and “very uncomfortable” categories during that period. This research concluded that build up area in UI Campus highest temperature on UI campus based on UHS. Range UHS in Campus UI on 2013 (21.8-31.1oC), 2014 (25.0-36.2oC) and 2015 (24.9-38.2oC). This maximum UHS on September (2014 and 2015) put on levelling UTCI included range temperature 32-35oC, with an explanation of sensation temperature is warm and sensation of comfort is Uncomfortable, Psychology with Increasing Stress Case by Sweating and Blood Flow and Health category is Cardiovascular Embarrassment. This UHS occurs in September will give impact on psychology and health, that’s become the UHH of the living on education area.
1 November 2019 in IOP Conference Series: Earth and Environmental Science
Global environmental change, as IPPC reported, its indication with air temperature getting a rise every year within 0.74 °C since the beginning of the 20th century. The consequence of that condition, every human will live with global environmental change. Urban Heat Signature is temperature behavior of land cover types as a representation of an urban environment. University Campus, as part of an urban environment, had an Urban Heat Signature. The research objective assessments of Urban Heat Signature impact on urban universities campus. Study area located in urban at University of Malaya (UM) and the University of Indonesia (UI). This research used spatial-temporal analysis to analysis Urban Heat Signature effect on a university campus with employed image satellite generated land surface temperature, ground trough collected air surface temperature and an online survey of human perception. This result saw that both UM and UI campuses found maximum Urban Heat Signature between 30-33.0°C and the UHS effect on air temperature with max >33.0°C then impact on human perception is very hot with uncomfortable sensation will getting a headache and lethargic then decreasing capacity and achievement of work or study at two urban universities. This result concluded that UHS impact on the university campus with air temperature more than 33.0°C and heat intensity would impact on human health and work activity, especially on study achievement. This result is significant to an understanding of UHS impact on human well-being in university campus as urban an environment.
1 November 2016 in IOP Conference Series: Earth and Environmental Science
Urban heat is a natural phenomenon which might caused by human activities. The human activities were represented by various types of land-use such as urban and non-urban area. The aim of this study is to identify the urban heat behavior in Tangerang City as it might threats the urban environment. This study used three types of remote sensing data namely, Landsat TM, Landsat ETM+ and Landsat OLI-TIRS, to capture the urban heat behavior and to analysis the urban heat signature of Tangerang City in 2001, 2012, 2013, 2014, 2015 and 2016. The result showed that urban heat signature change dynamically each month based on the sun radiation. The urban heat island covered only small part of Tangerang City in 2001, but it was significantly increased and reached 50% of the area in 2012. Based on the result on urban heat signature, the threshold for threatening condition is 30 oC which recognized from land surface temperature (LST). The effective temperature (ET) index explains that condition as warm, uncomfortable, increase stress due to sweating and blood flow and may causing cardiovascular disorder.
1 November 2019 in IOP Conference Series: Earth and Environmental Science
Komering Watershed has experienced degradation in the quality of environment and ecosystems. This ecosystem and environmental degradation is due to significant deforestation and land conversion in upstream and central areas. Land conversion which led to erosion in the upstream and sedimentation in the downstream causing changes in river channel. This study aims to analyze the deformation (morphodynamics) of river channel of Komering River in 1990, 1997, 2000, 2010 and 2013. The occurred changes are identified using satellite image interpretation and calculation from sinuosity index based on changes in river channel. Satellite image data are obtained from multitemporal Landsat images to identify changes in the river channel, while sinuosity index is used as an indicator of changes in the river channel. The results of this study showed that during 26 years period (1990 - 2016), the channel of Komering River changes in eleven locations. There are five locations that indicate tendencies to be straight and six locations show tendencies to get curved. This conclusion is based on the calculation of the sinuosity index value due to changes in land cover.
16 May 2018 in IOP Conference Series: Earth and Environmental Science
In this paper, two methods to retrieve the Land Surface Temperature (LST) from thermal infrared data supplied by band 10 and 11 of the Thermal Infrared Sensor (TIRS) onboard the Landsat 8 is compared. The first is mono window algorithm developed by Qin et al. and the second is split window algorithm by Rozenstein et al. The purpose of this study is to perform the spatial distribution of land surface temperature, as well as to determine more accurate algorithm for retrieving land surface temperature by calculated root mean square error (RMSE). Finally, we present comparison the spatial distribution of land surface temperature by both of algorithm, and more accurate algorithm is split window algorithm refers to the root mean square error (RMSE) is 7.69° C.