Ying Li

Prof. Dr. Ying Li


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Experimental Eye Research
Verified
Journal Article
Closed access
JWJingyi Wang
Jingyi Wang
YLYang Liu
Yang Liu
WKWendy R. Kam
Wendy R. Kam
YLYing Li
Ying Li
DSDavid A. Sullivan
David A. Sullivan

5 August 2016 in Chinese Medical Journal
Verified
Journal Article
Open access
PDF file
YJYang Jiang
Yang Jiang
YLYing Li
Ying Li
XLXiao-Wei Liu
Xiao-Wei Liu
JXJing Xu
Jing Xu
Background: Small incision refractive lenticule extraction (SMILE) is an effective laser procedure that treats myopia. This research was to describe a novel approach to treat corneal ulcer or perforation using the corneal lenticules obtained from SMILE and to evaluate the safety and effectiveness of tectonic keratoplasty with femtosecond laser intrastromal lenticule (TEKIL). Methods: A total of twenty patients (22 eyes) were monitored for at least 6 months and were assessed using slit lamp microscopy, optical coherence tomography, and best-corrected visual acuity (BCVA). Postoperative complications throughout the study period were recorded. Results: Corneal ulcer in 14 patients (16 eyes) and corneal perforation in six patients (6 eyes) were treated with TEKIL. The patients were ten females and ten males, with a mean age of 58.5 ± 16.3 years (range: 16–81 years). In this study, the most causes of corneal ulcer or perforation were immunologic causes (54.5%). After TEKIL procedure, global integrity was achieved in all cases. No immune rejection or perforation was detected. The mean BCVA improved from 0.17 ± 0.20 preoperatively to 0.27 ± 0.25 postoperatively at the final follow-up (t = 2.095, P = 0.052). The postoperative BCVA improved in 12 eyes (54.5%) and maintained in nine eyes (40.9%). Vision function successfully maintained in all eyes (100%). In three cases, corneal ulcers were treated by reoperation of TEKIL at 3 months after the initial surgery for the reason that the residual corneal thickness was <250 μm. Conclusions: TEKIL seems to be an effective treatment for corneal ulcer and perforation in the condition of emergency and donor shortage.

27 November 2021 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
YJYang Jiang
Yang Jiang
SLShang Lou
Shang Lou
YLYing Li
Ying Li
YCYouxin Chen
Youxin Chen
TLThomas Chengxuan Lu
Thomas Chengxuan Lu
Objective: To investigate whether there are differences inmacular vascular density (VD) between patients with high-myopia (HM) and those with non-high myopia (NHM) using Optical Coherence Tomography Angiography (OCTA). Method: OCTA was performed on 35 eyes with HM with spherical equivalence (SE) > − 6.00D and 35 eyes with NHM with SE ≤ -6.00D. Vascular densities of the macula (overall macula, fovea, parafovea, superior hemi and inferior hemi) were measured in each of the superficial, deep and choriocapillaris layers of the retina. Results: In the superficial retinal layer, overall macular VFD was significantly higher in the NHM compared to the HM group (51.27 ± 3.74 vs. 48.07 ± 5.69, p < 0.05). There were significant differences between the NHM and HM in parafovea (52.58 ± 5.78 vs. 49.4 ± 6.43, p < 0.05), superior-hemi (53.38 ± 4.03 vs 49.78 ± 6.84, p < 0.05) and inferior-hemi regions (53.49 ± 4.61 vs 49.05 ± 6.41, p < 0.05), but not in the fovea region. Similarly, in the deep retinal layer, overall macular VFD was significantly higher in the NHM group compared to the HM group (58.69 ± 2.46 vs. 56.90 ± 4.08, p < 0.05). There was significant differences between the HM and NHM in superior-hemi region (61.97 ± 2.68 vs. 60.08 ± 3.98, p < 0.05), but not in the fovea, parafovea, and inferior-hemi region. In the choriocapillaris, there was no difference in the overall macular VFD, nor any of the individual sectors between the HM and the NHM groups. Conclusion: VFD in the superficial and deep retinal layers of the macula are significantly increased in the NHM compared to HM eyes. This is not the case in the choroidal capillary layers of the retina.

1 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
QLQin Long
Qin Long
XCXiaoguang Cao
Xiaoguang Cao
ABAiling Bian
Ailing Bian
YLYing Li
Ying Li
Complement activation, specifically complement 3 (C3) activation and C3a generation, contributes to an imbalance between angiogenic stimulation by vascular endothelial growth factor (VEGF) and angiogenic inhibition by pigment epithelial derived factor (PEDF), leading to pathological angiogenesis. This study aimed to investigate the effects of C3a and small interfering RNA (siRNA) targeting C3 on the levels of VEGF and PEDF mRNAs in human retinal pigment epithelial (RPE) cells. ARPE-19 cells were cultured in the presence of exogenous C3a at 0.1 μM and 0.3 μM C3a for 24, 48, and 72 hours. 0.1 pmol/μL duplexes of siRNA targeting C3 were applied for C3a inhibition by transfecting ARPE-19 cells for 48 hours. RT-PCR was performed to examine the level of VEGF and PEDF mRNA. A random siRNA duplex was set for control siRNA. Results demonstrated that exogenous C3a significantly upregulated VEGF and downregulated PEDF mRNA levels in cultured ARPE-19 cells, and siRNA targeting C3 transfection reversed the above changes, significantly reducing VEGF and enhancing PEDF mRNAs level in ARPE-19 cells compared to the control. The present data provided evidence that reducing C3 activation can decreases VEGF and increase PEDF mRNA level in RPE and may serve as a potential therapy in pathological angiogenesis.

1 January 2015 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
QLQin Long
Qin Long
JWJingyi Wang
Jingyi Wang
XYXue Yang
Xue Yang
YJYumei Jin
Yumei Jin
FAFengrong Ai
Fengrong Ai
YLYing Li
Ying Li
Purpose. To investigate corneal biomechanical properties in patients with dry eye and in healthy subjects using Corneal Visualization Scheimpflug Technology (CorVis ST).Methods.Biomechanical parameters were measured using CorVis ST in 28 eyes of 28 patients with dry eye (dry eye group) and 26 normal subjects (control group). The Schirmer I test value, tear film break-up time (TBUT), and corneal staining score (CSS) were recorded for each eye. Biomechanical properties were compared between the two groups and bivariate correlation analysis was used to assess the relationship between biomechanical parameters and dry eye signs.Results.Only one of the ten biomechanical parameters was significantly different between the two groups. Patients in the dry eye group had significantly lower highest concavity time (HC-time) (P=0.02) than the control group. Correlation analysis showed a significant negative correlation between HC-time and CSS with marginalPvalue (ρ=-0.39,P=0.04) in the dry eye group.Conclusions.The corneal biomechanical parameter of HC-time is reduced in dry eyes compared to normal eyes. There was also a very weak but significant negative correlation between HC-time and CSS in the dry eye group, indicating that ocular surface damage can give rise to a more compliant cornea in dry eyes.

2 January 2024 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
YDYu Di
Yu Di
HFHuihui Fang
Huihui Fang
YLYan Luo
Yan Luo
YLYing Li
Ying Li
Yanwu XuYanwu Xu
Yanwu Xu
Purpose: To predict the vault size after Implantable Collamer Lens (ICL) V4c implantation using machine learning methods and to compare the predicted vault with the conventional manufacturer's nomogram. Methods: This study included 707 patients (707 eyes) who underwent ICL V4c implantation at the Department of Ophthalmology, Peking Union Medical College Hospital, from September 2019 to January 2022. Random Forest Regression (RFR), XGBoost, and linear regression (LR) were used to predict the vault size 1 week after ICL V4c implantation. The mean absolute error (MAE), median absolute error (MedAE), root mean square error (RMSE), symmetric mean absolute percentage error (SMAPE), and Bland–Altman plot were utilized to compare the prediction performance of these machine learning methods. Results: The dataset was divided into a training set of 180 patients (180 eyes) and a test set of 527 patients (527 eyes). XGBoost had the lowest prediction error, with mean MAE, RMSE, and SMAPE values of 121.70 µm, 148.87 µm, and 19.13%, respectively. The Bland‒Altman plots of RFR and XGBoost showed better prediction consistency than LR. However, XGBoost showed narrower 95% limits of agreement (LoA) than RFR, ranging from −307.12 to 256.59 µm. Conclusions: XGBoost demonstrated better predictive performance than RFR and LR, as it had the lowest prediction error and the narrowest 95% LoA. Machine learning may be applicable for vault prediction, and it might be helpful for reducing the complications and the secondary surgery rate. Translational Relevance: Using the proposed machine learning model, surgeons can consider the postoperative vault to reduce the surgical complications.