Purpose: Patient-level data from two large studies of the Zilver PTX drug-eluting stent (DES) with long-term follow-up and concurrent non-drug comparator groups were analyzed to determine whether there was an increased mortality risk due to paclitaxel. Methods: Data from the Zilver PTX randomized controlled trial (RCT) and Zilver PTX and bare metal stent (BMS) Japan post-market surveillance studies were analyzed. Five-year follow-up is complete in both DES studies; follow-up for the BMS study was limited to 3 years and is complete. Kaplan–Meier analyses assessed mortality. A Cox proportional hazards model identified significant factors related to mortality. Results: In the RCT, there were 336 patients treated with the DES and 143 patients treated with percutaneous transluminal angioplasty (PTA) or BMS. In Japan, there were 904 DES patients and 190 BMS patients. There was no difference in all-cause mortality for the DES compared to PTA/BMS in the RCT (19.1% DES versus 17.1% PTA/BMS through 5 years, p = 0.60) or Japan (15.8% DES versus 15.3% BMS through 3 years, p = 0.89). Cox proportional hazard models revealed that age, tissue loss, and congestive heart failure were significantly associated with mortality in the RCT, and critical limb ischemia, age, renal failure, and gender were significantly associated with mortality in Japan (all p < 0.05). Neither treatment with Zilver PTX (p = 0.46 RCT, p = 0.49 Japan) nor paclitaxel dose (p = 0.86 RCT, p = 0.07 Japan) was associated with mortality. Conclusion: Analyses of the Zilver PTX patient-level data demonstrated no increase in long-term all-cause mortality. Level of Evidence: Zilver PTX RCT: Level 1, randomized controlled trial; Japan PMS studies: Level 3, post-market surveillance study.
1 February 2020 in Journal of Vascular and Interventional Radiology
To report final 2-year outcomes with the Sentry bioconvertible inferior vena cava (IVC) filter in patients requiring temporary protection against pulmonary embolism (PE). In a prospective multicenter trial, the Sentry filter was implanted in 129 patients with documented deep vein thrombosis (DVT) and/or PE (67.5%) or who were at temporary risk of developing DVT/PE (32.6%). Patients were monitored and bioconversion status ascertained by radiography, computed tomography (CT), and CT venography through 2 years. The composite primary 6-month endpoint of clinical success was achieved in 97.4% (111/114) of patients. The rate of new symptomatic PE was 0% (n = 126) through 1 year and 2.4% (n = 85) through the second year of follow-up, with 2 new nonfatal cases at 581 and 624 days that were adjudicated as not related to the procedure or device. Two patients (1.6%) developed symptomatic caval thrombosis during the first month and underwent successful interventions without recurrence. No other filter-related symptomatic complications occurred through 2 years. There was no filter tilting, migration, embolization, fracture, or caval perforation and no filter-related deaths through 2 years. Filter bioconversion was successful for 95.7% (110/115) of patients at 6 months, 96.4% (106/110) of patients at 12 months, and 96.5% (82/85) of patients at 24 months. Through 24 months of follow-up, there was no evidence of late-stage IVC obstruction or thrombosis after filter bioconversion or of thrombogenicity associated with retracted filter arms. The Sentry IVC filter provided safe and effective protection against PE, with a high rate of intended bioconversion and a low rate of device-related complications, through 2 years of follow-up.
1 June 2021 in The Journal of Thoracic and Cardiovascular Surgery