Hirokazu Ishii

Dr. Hirokazu Ishii


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KJKanno Junji
Kanno Junji
TSTakuhei Shoji
Takuhei Shoji
HIHirokazu Ishii
Hirokazu Ishii
HIHisashi Ibuki
Hisashi Ibuki
YYYuji Yoshikawa
Yuji Yoshikawa
KSKei Shinoda
Kei Shinoda
The extraction of the foveal avascular zone (FAZ) from optical coherence tomography angiography (OCTA) images has been used in many studies in recent years due to its association with various ophthalmic diseases. In this study, we investigated the utility of a dataset for deep learning created using Kanno Saitama Macro (KSM), a program that automatically extracts the FAZ using swept-source OCTA. The test data included 40 eyes of 20 healthy volunteers. For training and validation, we used 257 eyes from 257 patients. The FAZ of the retinal surface image was extracted using KSM, and a dataset for FAZ extraction was created. Based on that dataset, we conducted a training test using a typical U-Net. Two examiners manually extracted the FAZ of the test data, and the results were used as gold standards to compare the Jaccard coefficients between examiners, and between each examiner and the U-Net. The Jaccard coefficient was 0.931 between examiner 1 and examiner 2, 0.951 between examiner 1 and the U-Net, and 0.933 between examiner 2 and the U-Net. The Jaccard coefficients were significantly better between examiner 1 and the U-Net than between examiner 1 and examiner 2 (p < 0.001). These data indicated that the dataset generated by KSM was as good as, if not better than, the agreement between examiners using the manual method. KSM may contribute to reducing the burden of annotation in deep learning.

Verified
Journal Article
Open access
PDF file
TSTakanori Sasaki
Takanori Sasaki
TSTakuhei Shoji
Takuhei Shoji
KJKanno Junji
Kanno Junji
HIHirokazu Ishii
Hirokazu Ishii
YYYuji Yoshikawa
Yuji Yoshikawa
KSKei Shinoda
Kei Shinoda
To evaluate the automated determination of the center of an idiopathic macular hole (MH) by using swept-source optical coherence tomography (OCT) images with new macro-based algorithms in ImageJ and to compare the difference between the MH center measurements obtained automatically and manually. This cross-sectional study included 39 eyes of 39 elderly individuals (22 women, 17 men) with stage 3 and 4 MH. The MH center was automatically determined using the ImageJ macro. The foveal center was also manually identified by two masked examiners using horizontal and vertical serial B-scan OCT angiography images. The mean age was 68.8 ± 8.3 years. After adjusting for the effect of magnification, the mean distance between the MH center determined manually by Examiner 1 and that determined automatically was 15.5 ± 9.9 µm. The mean distance between the two manually determined measurements of the MH center was 20.3 ± 19.7 µm. These two mean distance values did not differ significantly (Welch t-test, p = 0.27) and was non-inferior (p < 0.0001). The automated ImageJ-based method for determining the MH center was comparable to manual methods. This study showed that automated measurements were non-inferior to manual measurements, and demonstrated a substitutable usefulness, at least for use in clinical practice.

7 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TSTakuhei Shoji
Takuhei Shoji
MSMiho hashimoto Seo
Miho hashimoto Seo
HIHisashi Ibuki
Hisashi Ibuki
HIHirokazu Ishii
Hirokazu Ishii
JKJunji Kanno
Junji Kanno
KSKei Shinoda
Kei Shinoda
Background/Objectives: We aim to develop an image linearization process and a program capable of quantifying vertical and left–right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients with unilateral open-angle glaucoma and analyzed paired data (glaucomatous eye vs. fellow normal eye). Spectral-domain OCT images were automatically processed by a custom program to align the disc–fovea axis and temporal raphe, and the following parameters were evaluated: (1) mean inner retinal thickness difference (superior–inferior), (2) Vertical Asymmetry Score, and (3) Quadrantal Asymmetry Score. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thicknesses for the normal and POAG groups were 93.4 µm (interquartile range [IQR]: 90.1–98.5) and 80.3 µm (IQR: 77.3–85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15–7.25) for healthy eyes and 9.69 (IQR: 9.16–11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94–7.19) for healthy eyes and 8.47 (IQR: 8.11–9.63) for POAG eyes. Significant differences were found between groups for all parameters (p < 0.001). The Vertical Asymmetry Score (AUC = 0.967, p < 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p < 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusions: The developed linearization program and asymmetry scores have shown promise as parameters for objectively quantifying macular asymmetry using spectral-domain OCT. External validation in independent cohorts, including bilateral disease, is warranted.

24 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
TSTakuhei Shoji
Takuhei Shoji
MSMiho hashimoto Seo
Miho hashimoto Seo
HIHisashi Ibuki
Hisashi Ibuki
HIHirokazu Ishii
Hirokazu Ishii
JKJunji Kanno
Junji Kanno
KSKei Shinoda
Kei Shinoda
Background/Aims: To develop an image linearization process and a program capable of quantifying vertical and left-right asymmetries observed in macular scans. We then sought to verify its applicability in clinical settings. Methods: In this single-center cross-sectional study, we examined 37 consecutive patients diagnosed with open-angle glaucoma in one eye, with the other eye being normal. Spectral-domain OCT images were automatically processed by a program we developed to straighten the disc-macula and macula-temporal raphe lines. The following parameters were then analyzed: 1) Mean inner retinal thickness difference between the superior and inferior segments, 2) Vertical Asymmetry Score, and 3) Quadrantal Asymmetry Score. These parameters were automatically measured, and their values were compared between the two eyes.. Results: We analyzed 37 healthy eyes and 37 POAG eyes. After linearization, the mean inner retinal thickness for the normal and POAG groups was 93.4 µm (interquartile range [IQR]: 90.1-98.5) and 80.3 µm (IQR: 77.3-85.0), respectively. The Vertical Asymmetry Score was 6.80 (IQR: 6.15-7.25) for healthy eyes and 9.69 (IQR: 9.16-11.58) for POAG eyes. The Quadrantal Asymmetry Score was 6.35 (IQR: 5.94-7.19) for healthy eyes and 8.47 (IQR: 8.11-9.63) for POAG eyes. Significant differences were found between groups for all parameters (p< 0.001). The Vertical Asymmetry Score (AUC = 0.967, p< 0.001) and Quadrantal Asymmetry Score (AUC = 0.946, p< 0.001) demonstrated significantly greater accuracy in detecting glaucoma compared to the mean inner retinal thickness (AUC = 0.743). Conclusion: The developed linearization program and asymmetry scores have shown promise as parameters for detecting glaucomatous changes in macular scans using spectral-domain OCT.