The functional dynamics and cellular sources of oxidative stress are central to understanding MS pathogenesis but remain elusive, due to the lack of appropriate detection methods. Here we employ NAD(P)H fluorescence lifetime imaging to detect functional NADPH oxidases (NOX enzymes) in vivo to identify inflammatory monocytes, activated microglia, and astrocytes expressing NOX1 as major cellular sources of oxidative stress in the central nervous system of mice affected by experimental autoimmune encephalomyelitis (EAE). This directly affects neuronal function in vivo, indicated by sustained elevated neuronal calcium. The systemic involvement of oxidative stress is mirrored by overactivation of NOX enzymes in peripheral CD11b+ cells in later phases of both MS and EAE. This effect is antagonized by systemic intake of the NOX inhibitor and anti-oxidant epigallocatechin-3-gallate. Together, this persistent hyper-activation of oxidative enzymes suggests an “oxidative stress memory” both in the periphery and CNS compartments, in chronic neuroinflammation.
The development of intravital Förster Resonance Energy Transfer (FRET) is required to probe cellular and tissue function in the natural context: the living organism. Only in this way can biomedicine truly comprehend pathogenesis and develop effective therapeutic strategies. Here we demonstrate and discuss the advantages and pitfalls of two strategies to quantify FRET in vivo—ratiometrically and time-resolved by fluorescence lifetime imaging—and show their concrete application in the context of neuroinflammation in adult mice.
Purpose The aim of this study was to investigate the diagnostic accuracy of computed tomography (CT) for the prediction of ablation zones from microwave ablation (MWA) and cryoablation (CA) in an ex vivo porcine liver model. Methods Sequential (30 seconds) CT scans were acquired during and after MWA and CA in an ex vivo porcine liver model. We generated 120-kVp equivalent reconstructions of generic dual-energy CT data sets, and comprehensive region-of-interest measurements were statistically correlated with invasive temperature monitoring using Pearson correlation coefficient. Binary logistic regression was performed for prediction of successful ablation. Results With the use of pooled data from 6 lesions in 2 separate experiments, correlation analysis of attenuation in Hounsfield units (HU) and temperature yieldedr= -0.79 [confidence interval (CI), -0.85 to -0.71] for MWA andr= 0.62 (CI, 0.55 to 0.67) for CA. For MWA, there was a linear association between attenuation and temperature up to 75 degrees C; thus, linear regression yielded a slope of -2.00 HU/degrees C (95% CI, -1.58 to -2.41). For CA, a linear association between attenuation and temperature was observed in the cooling phase with a slope of 2.11 HU/degrees C (95% CI, 1.79 to 2.58). In MWA treatment, binary logistic regression separated less than 70 degrees C and greater than 70 degrees C with 89.2% accuracy. Within the ice ball, temperatures above and below -20 degrees C were distinguished with 65.3% accuracy. Conclusions Our experiments reveal several difficulties in predicting ablation zone temperature from CT attenuation. Microwave ablation leads to gas production in the tissue, which degrades the accuracy of noninvasive temperature measurement, especially at higher temperatures. In CA, CT thermometry is limited by ice ball formation, which leads to homogeneous attenuation, nearly independent of temperature. Further research is needed to define the role of CT thermography in ablation zone monitoring in liver malignancies.