Nermin Oprasic

Mr. Nermin Oprasic


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020
Verified
Conference Paper
Closed access
Selma GREBOVICSelma GREBOVIC
Selma GREBOVIC
NONermin Oprasic
Nermin Oprasic
ABA. Balota
A. Balota
Different types of transient phenomena are found in power systems. Switching transients in power systems have always been a matter of concern in insulation coordination studies. The reactors in power system are widely used elements which purpose is to provide stable power flow in normal conditions and to reduce dynamical and thermal stresses during short circuits and some other faults. Many shunt reactors are switched frequently, even daily. Shunt reactor switching imposes a unique and severe stress on the connected system and the circuit breaker. This paper presents study of overvoltages due to shunt reactor switching in 400 kV substation.

12 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Selma GREBOVICSelma GREBOVIC
Selma GREBOVIC
NONermin Oprasic
Nermin Oprasic
AFAjdin Fejzic
Ajdin Fejzic
HKHarun Kartal
Harun Kartal
Abdulah AkšamovićAbdulah Akšamović
Abdulah Akšamović
Samim KonjicijaSamim Konjicija
Samim Konjicija
Large-scale incorporation of new energy generation units based on renewable sources, such as wind and photovoltaic power, drastically alters the structure of the power system. Because of the intermittent nature of these sources, switching in grids (connection and disconnection) occurs much more frequently than with conventional sources. As a result, the power system will inevitably experience a large number of transients, which raises questions about the stability of the system and the quality of the electrical energy. Therefore, measuring various types of transients in power system is crucial for stability, power quality, fault analysis, protection design, and insulation design. Transient recorders that are currently used are generally expensive and only suitable for particular locations in power systems. The number of installed transient recorders is insufficient for a comprehensive analysis of problems that may occur. Hence, it is important to have inexpensive and efficient transient recorders that can be installed at multiple points in the power system on various types of objects. It is also essential to have a transient record database with open access, which can be used by researchers to develop new analysis techniques based on artificial intelligence. This paper proposes an inexpensive measurement and acquisition system designed to record transient phenomena on different objects within the power system. The system is designed to use autonomous power, a standardized data acquisition module, a low-budget system for transmitting recorded transient events to the server via mobile network, and a sensor system adapted to the object where transients are recorded. The proposed system is designed to be used for all types of objects in the power system where transients may occur, such as power lines, transmission towers, surge arresters, and transformers. All components of the system are described, and the system is tested under laboratory conditions. The modular nature of the system allows customization to the specifics of the location in power system by choosing appropriate components. The calibration method of the custom designed Rogowski coil is described. The cost analysis of the proposed system and power consumption analysis are performed. The results show that the system’s performance meets application requirements at a low cost.

16 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Selma GREBOVICSelma GREBOVIC
Selma GREBOVIC
NONermin Oprasic
Nermin Oprasic
Vahid HelacVahid Helac
Vahid Helac
IUIvo Uglešić
Ivo Uglešić
Abdulah AkšamovićAbdulah Akšamović
Abdulah Akšamović
Samim KonjicijaSamim Konjicija
Samim Konjicija
Lightning parameters are needed in different engineering applications. For the prediction of the severity of transient voltages in power systems, an accurate knowledge of the parameters of lightning currents is essential. All relevant standards and technical brochures recommend that lightning characteristics should be classified according to geographical regions instead of assuming that these characteristics are globally uniform. Many engineers and scientists suggest that better methods for lightning current measurements and analyses need to be developed. A system for direct lightning current measurements installed on Mount Lovćen is described in this paper. Observed data were analyzed, and statistical data on parameters that are of interest for engineering applications were obtained, as well as correlations between various lightning parameters. Furthermore, a novel approach for classifying and analyzing lightning data from direct measurements based on empirical mode decomposition (EMD) is proposed. Matlab was used as a tool for signal processing and statistical analysis. The methodology implemented in this work opens possibilities for automated analysis of large data sets and expressing lightning parameters in probabilistic terms from the data measured on site.

1 June 2020
Verified
Conference Paper
Closed access
Selma GREBOVICSelma GREBOVIC
Selma GREBOVIC
ABA. Balota
A. Balota
NONermin Oprasic
Nermin Oprasic
Lightning is the main cause of line outages on overhead distribution lines, especially for lines located in mountain areas and without line surge arresters installed along the line. This paper is dedicated to lightning outage performance of distribution line “Kotor – Lovćen” that operates in mountain Lovćen area. Shielding failure rate, shielding failure flashover rate and back flashover rate are calculated using Sigma Slp software. Lightning data collected by two advanced lightning activity monitoring systems are analyzed and used in number of simulations conducted for purposes of this paper.

1 October 2018
Verified
Conference Paper
Closed access
Selma GREBOVICSelma GREBOVIC
Selma GREBOVIC
NONermin Oprasic
Nermin Oprasic
This paper describes a detailed transmission line model for a transient analysis. Line surge arrester energy sharing and importance of complete transmission line modelling is explained. Lightning channel impedance and tower footing resistance are important parameters that influence line surge arrester energy duty. Therefore, energy stresses of transmission line surge arresters due to different values of lightning channel impedance and nonuniform distribution of tower footing resistance are considered.