Speech brain-computer interfaces (BCIs) offer a promising means to provide functional communication capacity for patients with anarthria caused by neurological conditions such as amyotrophic lateral sclerosis (ALS) or brainstem stroke. Current speech decoding research has predominantly focused on English using phoneme-driven architectures, whereas real-time decoding of tonal monosyllabic languages such as Mandarin Chinese remains a major challenge. This study demonstrates a real-time Mandarin speech BCI that decodes monosyllabic units directly from neural signals. Using the 256-channel microelectrocorticographic BCI, we achieved robust decoding of a comprehensive set of 394 distinct syllables based purely on neural signals, yielding median syllable identification accuracy of 71.2% in a single-character reading task. Leveraging this high-performing syllable decoder, we further demonstrated real-time sentence decoding. Our findings demonstrate the efficacy of a tonally integrated, direct syllable neural decoding approach for Mandarin Chinese, paving the way for full-coverage systems in tonal monosyllabic languages.
Brain‐computer interfaces (BCIs) enable communication between individuals and computers or other assistive devices by decoding brain activity, thereby reconstructing speech and motor functions for patients with neurological disorders. This study presents a high‐resolution micro‐electrocorticography (µECoG) BCI based on a flexible, high‐density µECoG electrode array, capable of chronically stable and real‐time motor decoding. Leveraging micro‐nano manufacturing technology, the µECoG BCI achieves a 64‐fold increase in electrode density compared to conventional clinical electrode arrays, enhancing spatial resolution while featuring scalability. Over a 203‐day in vivo experiment, high‐resolution µECoG carrying fine spatial specificity information demonstrated the potential to improve decoding performance while reduce implanted devices size. These advancements provide a pathway to overcome the limitations of conventional ECoG BCIs. During awake surgery, the µECoG BCI enabled game control after 7 min of model training. Furthermore, during practice of 19.87 h, the participant achieved cursor control with a bit rate of 1.13 bits per second (BPS) under full volitional control, and the bit rate reached up to 4.15 BPS with enhanced user interface. These results show that the µECoG BCI achieves comparable performance to intracortical electroencephalographic (iEEG) BCIs without intracortical invasiveness, marking a breakthrough in the clinical feasibility of flexible BCIs.
Recent advancements in neural probe technology have become pivotal in both neuroscience research and the clinical management of neurological disorders. State-of-the-art developments have led to the advent of multichannel, high-density bidirectional neural interfaces that are adept at both recording and modulating neuronal activity within the central nervous system. Despite this progress, extant bidirectional probes designed for simultaneous recording and stimulation are beset with limitations, including elicitation of inflammatory responses and insufficient charge injection capacity. In this paper, we delineate the design and application of an innovative ultraflexible bidirectional neural probe engineered from polyimide. This probe is distinguished by its ability to facilitate high-resolution recordings and precise stimulation control in deep brain regions. Electrodes enhanced with a PEDOT:PSS/IrOx composite exhibit a substantial increase in charge storage capacity, escalating from 0.14 ± 0.01 mC/cm2 to an impressive 24.75 ± 0.18 mC/cm2. This augmentation significantly bolsters the electrodes’ charge transfer efficacy. In tandem, we observed a notable reduction in electrode impedance, from 3.47 ± 1.77 MΩ to a mere 41.88 ± 4.04 kΩ, while the phase angle exhibited a positive shift from −72.61 ± 1.84° to −34.17 ± 0.42°. To substantiate the electrodes’ functional prowess, we conducted in vivo experiments, where the probes were surgically implanted into the bilateral motor cortex of mice. These experiments involved the synchronous recording and meticulous analysis of neural signal fluctuations during stimulation and an assessment of the probes’ proficiency in modulating directional turning behaviors in the subjects. The empirical evidence corroborates that targeted stimulation within the bilateral motor cortex of mice can modulate the intensity of neural signals in the stimulated locale, enabling the directional control of the mice’s turning behavior to the contralateral side of the stimulation site.
Wireless neural signal transmission is essential for both neuroscience research and neural disorder therapies. However, conventional wireless systems are often constrained by low sampling rates, limited channel counts, and their support of only a single transmission mode. Here, we developed a wireless bi-directional brain–computer interface system featuring dual transmission modes. This system supports both low-power Bluetooth transmission and high-sampling-rate Wi-Fi transmission, providing flexibility for various application scenarios. The Bluetooth mode, with a maximum sampling rate of 14.4 kS/s, is well suited for detecting low-frequency signals, as demonstrated by both in vitro recordings of signals from 10 to 50 Hz and in vivo recordings of 16-channel local field potentials in mice. More importantly, the Wi-Fi mode, offering a maximum sampling rate of 56.8 kS/s, is optimized for recording high-frequency signals. This capability was validated through in vitro recordings of signals from 500 to 2000 Hz and in vivo recordings of single-neuron spike firings with amplitudes reaching hundreds of microvolts and high signal-to-noise ratios. Additionally, the system incorporates a wireless stimulation function capable of delivering current pulses up to 2.55 mA, with adjustable pulse width and polarity. Overall, this dual-mode system provides an efficient and flexible solution for both neural recording and stimulation applications.
Flexible neural interfaces capable of monitoring subcortical neuronal activity facilitate the study of deep brain neural circuits and their interactions with the cortex. However, there exists a paucity of translational tools for interfacing subcortical nuclei surfaces within the intraventricular cerebrospinal fluid. Here, we developed a flexible and conformal intraventricular interface (IVI) featuring a deformable microelectrode array paired with a silk scaffold. The IVI can be minimally invasively implanted into the lateral ventricles with the assistance of commonly used clinical catheters, self-unfolding in the cerebrospinal fluid environment to conformally attach to the surfaces of periventricular neural structures, and capturing high-quality signals by virtue of the microelectrode’s in-plane shielding. In parkinsonian ewes, the IVI detects deep brain abnormalities and achieves stable, biocompatible in vivo recordings for four weeks. This platform enables chronic monitoring and circuit analysis of healthy and diseased deep brain regions, facilitating studies of neural circuits between periventricular surface neurons and distant brain areas.