The present study aimed to clinically evaluate the effect of T-cell dysfunction in hemodialysis (HD) patients with latent tuberculosis (TB) infection (LTBI) who were false-negatives in the QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Whole blood samples from a total of 20 active TB patients, 83 HD patients, and 52 healthy individuals were collected, and the QFT-GIT test was used for measuring Mycobacterium tuberculosis (MTB)-specific interferon gamma (IFN-γ) level. The positive rate of the IFN-γ release assays (IGRAs) in HD patients was lower than the negative rate. The mean value of MTB-specific IFN-γ level, which determines the positive rate of the IGRA test, was highest in active TB, followed by HD patients and healthy individuals. Among HD patients, phytohemagglutinin A (PHA)-stimulated IFN-γ levels of approximately 40% were 10.00 IU/mL or less. However, there was no low level of PHA-stimulated IFN-γ in the healthy individuals. This reveals that T-cell function in HD patients was reduced compared to healthy individuals, which leads to the possibility that QFT-GIT results in HD patients are false-negative. The clinical manifestations of TB in patients on HD are quite non-specific, making timely diagnosis difficult and delaying the initiation of curative treatment, delay being a major determinant of outcome.
Background: When a body is discovered at a crime or murder scene, it is crucial to examine the body and estimate its postmortem interval (PMI). Accurate estimation of PMI is vital for identifying suspects and providing clues to resolve the case. MicroRNAs (miRNAs or miRs) are small non-coding RNAs that remain relatively stable in the cell nucleus even after death-related changes occur. Objective: This study developed a molecular beacon probe for mmu-miR-133a-5p and assessed its use in mouse muscle tissue at temperatures of 4 °C and 21 °C to estimate the PMI. Methods: A total of 36 healthy adult male BALB/c mice were divided into 9 PMI time points (0, 2, 6, 8, and 10 days) with 3 mice per time point, and they were exposed to 4 °C and 21 °C. Next, the expression pattern of mmu-miR-133a in the skeletal muscle tissue over a 10-day PMI period was analyzed using the developed molecular beacon probe. Results: The molecular beacon (MB) probe was designed for optimal thermodynamic stability with a hairpin structure that opened in the presence of mmu-miR-133a-5p, thus separating the fluorophore from the quencher and resulting in a strong fluorescence signal at 495 nm. Fluorescence intensity increased with mmu-miR-133a-5p concentration from 1 ng/μL to 1000 ng/μL and exhibited a strong correlation (R2 = 0.9966) and a detection limit of 1 ng/μL. Subsequently, the expression level of mmu-miR-133a-5p was observed to be stable in mouse skeletal muscle tissue at both 4 °C and 21 °C. Conclusions: This user-friendly assay can complete measurements in just 30 min after RNA extraction and is suitable for point-of-care testing, and it possesses the potential to improve existing complex and time-consuming methods for PMI estimation.
Background: Tuberculosis (TB) is still the main cause of mortality due to a single transfectant, Mycobacterium tuberculosis (MTB). Latent tuberculosis infection (LTBI) is a condition characterized by the presence of tuberculosis (TB) that is not clinically apparent but nonetheless shows a sustained response to MTB. Presently, tuberculin skin test (TST) and interferon gamma (IFN-γ) release assays (IGRAs) are mainly used to detect LTBI via cell-mediated immunity of T-cells. For people with end-stage renal disease (ESRD), the diagnosis of patients infected with MTB is difficult because of T-cell dysfunction. To get more accurate diagnosis results of LTBI, it must compensate for the deficiency of IGRA tests. Methods: Sixty-seven hemodialysis (HD) patients and 96 non-HD patients were enrolled in this study and the study population is continuously included. IFN-γ levels were measured by the QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Kidney function indicators, blood urea nitrogen (BUN), serum creatinine (Cr), and estimated glomerular filtration rate (eGFR) were used to compensate for the declined IFN-γ levels in the IGRA test. Results: In individuals who were previously undetected, the results of compensation with serum Cr increased by 10.81%, allowing for about 28% more detection, and compensation with eGFR increased by 5.41%, allowing for approximately 14% more detectable potential among them and employing both of them could enhance the prior shortcomings of IGRA tests. when both are used, the maximum compensation results show a sensitivity increase rate of 8.81%, and approximately 23% of patients who were previously undetectable may be found. Conclusion: Therefore, the renal function markers which are routine tests for HD patients to compensate for the deficiency of IGRA tests could increase the accuracy of LTBI diagnosis.
Myeong Gwan Kim, Soobin Choi, Seoyeon Jang, Ahee Cho, Sang Rae Kim, Sang-Hyun Park, and Jaewon Lim. BSL 2025;31:128-36. https://doi.org/10.15616/BSL.2025.31.2.128