This article focuses on wave impedance calculations employed in the transmission line analogy for the low-frequency magnetic shielding problem: a planar shield against a loop current source placed parallel to the shield. We present a unified formula for wave impedance calculations that is distinct from traditional definitions of the transverse E -field to H -field ratio, which is related to the ratio of the H -field components to its longitudinal derivative. The formula is relatively simple in terms of mathematical complexity when applied to derive a concrete wave impedance expression. For a circular loop, the formula produces the same wave impedance expression as the traditional definition for field points on the central axis of the loop. For field points off the axis, the formula more accurately predicts the shielding effectiveness relative to traditional definitions. Based on the proposed formula, we also obtain wave impedance expressions for rectangular, elliptical, and regular polygon loops under quasi-static assumptions. The effectiveness of these expressions is verified through comparisons with finite element simulations.
3 November 2021 in IEEE Transactions on Electromagnetic Compatibility
For the magnetic shielding configuration of both emitting and receiving loops placed coaxially on either side of a planar screen, we investigate the effects of loop radius and loop-to-loop distance on shielding effectiveness by numerically solving the accurate integral expression. The results are in good agreement with finite element simulations and experimental results. Simple and reliable approximate formulas are also proposed for pure conductive screens and pure magnetic screens, respectively. It is shown that the effects are obvious when the loop-to-loop distance is smaller than the loop radius. Also, conductive screens and magnetic screens exhibit opposite and competing shielding effectiveness evolution behaviors. In addition, in the case of conductive screens with a smaller receiving loop compared to the emitting loop, the shielded loop-to-loop mutual inductance does not always decrease with the increase of the loop-to-loop distance but peaks at a distance between the screen thickness and half of the emitting loop radius.
The primary side and secondary side of the 10kV digital circuit breaker is deeply integrated. Wherein, an electronic transformer is deployed together with the breaker inside a cabinet, and a digital unit is closely connected to the output port of electronic transform. This compact and close arrangement make the secondary side face severe electromagnetic environment during the switching operation of the breaker. In this paper, we report the measured electromagnetic disturbances resulted from the opening/closing of 20kA current by the breaker. The results show that the disturbance voltage at the secondary side port of the voltage transformer has the waveform of damped oscillatory waves, the peak value of up to 1.1kV, and the dominant frequencies 4.4MHz and 15MHz.The disturbance voltage at the secondary side port of the current transformer has the peak value of 350V. The peak value of dH/dt of the spatial magnetic field is 0.387kA·m -1 ·μs -1 . By comparing the measured waveforms with these specified in IEC 61000-4-18 and IEC 61000-4-10 standards, we advise that the level of immunity test is the third level of the fast damped oscillatory wave for voltage port and the fourth level of the damped oscillatory magnetic for enclosure port.
8 August 2022 in IEEE Transactions on Electromagnetic Compatibility
This letter proposes an accurate analytical formulation for the shielding problem of a perfectly electric conducting disk against the static magnetic field of a circular current loop placed coaxially with the disk. The key is to convert this problem into an electric field problem: the circular disk is grounded and is excited by nonuniform line charges distributed on the loop. The latter can be solved through the known Green function. Then, we obtain the accurate solution in integral form for magnetic vector potential at any field point and the accurate analytical solution for the magnetic field on the central axis of the disk. Also, the solution for the magnetic field is extended to the whole space when the loop radius is approaching zero.
22 February 2024 in IEEE Transactions on Electromagnetic Compatibility
Recently, the magnetic field penetration through a circular aperture in a thin perfect electric conductor when excited by a loop antenna placed coaxially with the aperture is solved analytically in the quasi-static frame. However, the analytical solution is only applicable to the longitudinal component. Here, we present two approaches to obtain the transverse component. The first one belongs to the direct extension of the earlier results, but lengthy mathematic derivations are performed to solve a complex integral. The second one utilizes the magnetic vector potential formulation and then converts it into a known scalar potential problem.