This paper seeks to evaluate the depth and outcomes of MyoRing implantation using two mechanical dissection procedures including: PocketMaker microkeratome in opposition to the Melles hook method. This retrospective study was carried out on 39 eyes of 38 keratoconus patients (28 male and 10 female) with the mean age of 28.97 + . 10.37 $$ 28.97\frac{+}{.}10.37 $$ years and had undergone MyoRing implantation by the two mentioned methods. The MyoRing was inserted into the corneal pocket which was made manually in 18 eyes (Melles hook group) or with PocketMaker microkeratome in 21 eyes (PocketMaker group). The mean follow up time was 9.81 + . 3.7 $$ 9.81\frac{+}{.}3.7 $$ months with pre-operative and post-operative ophthalmic examination including uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), keratometry readings and central corneal thickness measurement. AS-OCT (Casia, SS-1000, Tomey, Nagoya, Japan) imaging was used to measure MyoRing insertion depth, exactly. Pre-operative and post-operative UCVA (LogMAR) mean change for the PocketMaker and Melles hook groups were recorded at 0.75 ± 0.32 and 0.78 ± 0.33, respectively. Similarly, BCVA (LogMAR) mean change were 0.27 ± 0.22 and 0.23 ± 0.22. Mean keratometry (Kmean) change were 6.06 ± 4.18 and 6.56 ± 3.55 respectively. UCVA change (P = 0.767), BCVA change (P = 0.77) and Kmean change (P = 0.693) showed that there was no statistically significant difference between both groups for any parameter. Depth measurements achieved from AS-OCT images showed that there was no statistically significant difference in pocket depth between two methods of MyoRing implantation (P = 0.413). The results of Myoring implantation outcomes using mechanical dissection via PocketMaker microkeratome as against Melles hook are comparable.
Background: The aim of this study was to assess stress-strain index (SSI) and corneal biomechanical parameters in eyes with granular corneal dystrophy (GCD). Methods: This case-control study included 12 eyes of 12 patients with GCD (mean age 45.2 ± 18.7 years) and 20 eyes of 20 healthy individuals (mean age 54.4 ± 3.8 years). In addition to SSI, dynamic corneal response (DCR) parameters were assessed at the first and second applanation, including length (AL1, AL2), velocity (AV1, AV2), time (AT1, AT2), and deformation amplitude (DA A1, DA A2), and at the highest concavity (HC) phase, including DA, peak distance (PD), radius (HCR), and DA ratio (DAR 1 and 2 mm), by Corvis ST. Central corneal thickness (CCT) and biomechanically corrected intraocular pressure (bIOP) were considered covariates in comparing DCR parameters between the two groups. Results: SSI was statistically significantly lower in eyes with GCD than in normal eyes (p = 0.04). The corneal velocity towards the first applanation was 0.02 m/s faster in the GCD eyes AV1 (0.15 ± 0.02 vs. 0.13 ± 0.02 m/s, p < 0.001) and IR (7.48 ± 1.01 vs. 6.80 ± 1.22 mm, p = 0.003) parameters were significantly higher in the GDC group, while AT1 (7.33 ± 0.66 vs. 7.47 ± 0.36 ms, p = 0.002) and HCR (7.42 ± 0.76 vs. 8.20 ± 1.08 mm, p = 0.014) were significantly lower in the normal group. Conclusions: GCD led to a change in biomechanical properties of the cornea. SSI refers to fewer stiff corneas in GDC than normal.
10 February 2022 in American Journal of Ophthalmology Case Reports
To report a case with full thickness corneal laceration behind the intact LASIK flap after blunt trauma. A 48-year-old man with a history of LASIK surgery was hit by a shovel. Slit-lamp examination showed 4+ corneal edema. The anterior chamber (AC) was deep and the Seidel test was negative. Uncorrected distance visual acuity (UDVA) was hand motion. A more accurate evaluation was performed with an anterior segment optical coherence tomography (OCT) and it was found that the paracentral corneal tissue was ruptured while the flap remained completely intact. Under the surgical procedure, the rupture site was sutured, and then the flap was replaced, and two U-shaped sutures were performed to ensure the flap stability. Three months after surgery, corrected distance visual acuity (CDVA) was 9/10 decimal with a manifest refraction of +1–3 x 60°. In a traumatic post-LASIK eye, the posterior part of the flap should be carefully evaluated. The role of the OCT device in the diagnosis and management of complication is also very valuable.