Diabetic retinopathy (DR) is a common microvascular complication of diabetes. The mitochondrial unfolded protein response (UPRmt) is a key stress-adaptive mechanism, yet its role in DR remains unclear. This study aimed to investigate the involvement of UPRmt-related genes (MRGs) in DR. Transcriptomic datasets (GSE221521 and GSE189005) were analyzed to identify differentially expressed MRGs. Weighted gene co-expression network analysis (WGCNA), machine learning, and reverse transcription-quantitative polymerase chain reaction (RT-qPCR) were used to screen and validate biomarkers. Functional enrichment, nomogram construction, immune infiltration analysis, drug prediction, molecular docking, and regulatory network exploration were performed. GPR52 and FKBP9 were consistently upregulated in DR and showed good diagnostic potential (area under the curve [AUC ≥ 0.7]). A nomogram based on their expression demonstrated high predictive accuracy. Enrichment analysis suggested their roles in PI3K/Akt, Toll-like receptor, and neurotrophin signaling. FKBP9 correlated with altered CD8+ T cell and NK cell infiltration. Differential expression of CXCL9 and GZMA supported immune dysregulation. Molecular docking indicated stable interactions with small molecules, including ethinyl estradiol and bisphenol A. POU2F1 and several miRNAs were identified as potential regulators. GPR52 and FKBP9 may serve as UPRmt-related biomarkers in DR, contributing to metabolic and immune dysregulation. These findings offer insights into DR pathogenesis and may inform future personalized diagnostic and therapeutic strategies.
14 March 2024 in Computers in Biology and Medicine
This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs. A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied. Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models. The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%. In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.
Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).
1 August 2024 in Investigative Ophthalmology & Visual Science
Purpose: The role of specific extracellular matrix (ECM) molecules in lens cell development and regeneration is poorly understood, as appropriate cellular models are lacking. Here, a laminin-based lens cell in vitro induction system was developed to study the role of laminin in human lens epithelial stem/progenitor cell (LES/PC) development. Methods: The human embryonic stem cell–based lens induction system followed a three-stage protocol. The expression profile of laminins during lens induction was screened, and laminin-511 (LN511) was tested as a candidate substitute. LN511 induction system cellular and molecular features, including induction efficiency, transcription factor expression related to different lens development stages, ECM alterations, and Hippo/YAP signaling, were evaluated. Results: LAMA5, LAMB1, and LAMC1 were highly expressed around the time of LES/PC derivation. We chose LN511 (product of LAMA5, LAMB1, and LAMC1) and found that it considerably enhanced lens cell induction efficiency, compared to that in Matrigel-coated culture, as more and larger lentoid bodies were detected. Notably, LES/PC induction efficiency improved by promoting lens specification–related transcription factor expression and cell proliferation. Transcriptome analysis revealed that compared to those with Matrigel, ECM accumulation and cell adhesion were downregulated in the LN511 system. Hippo/YAP signaling was hypoactive during LES/P-like cell generation, and small molecule inhibitors of YAP/TAZ activity upregulated LES/PC marker expression and promoted the efficiency of LES/P-like cell derivation. Conclusions: The laminin isoform LN511 is a reliable substitute for the LES/P-like cell induction system, and LN511-YAP acted as efficient modulators of LES/PC derivation; this contributes to knowledge of the role of the ECM in human lens development.
18 August 2023 in International Journal of Ophthalmology
ZOZhongshan Ophthalmic Center State Key Laboratory Of Ophthalmology
Zhongshan Ophthalmic Center State Key Laboratory Of Ophthalmology
HHHao Huang
Hao Huang
+3
AIM: To investigate thickness characteristics and vascular plexuses in retinas with reticular pseudodrusen (RPD) as an early detection strategy for age-related macular degeneration (AMD). METHODS: This retrospective study included 24 subjects (33 eyes) with RPD and 25 heathy control subjects (34 eyes). The superficial capillary plexus (SCP) and the deep capillary plexus (DCP) of the retinal posterior poles were investigated with optical coherence tomography angiography (OCTA). Retinal thicknesses and vessel densities were analyzed statistically. RESULTS: The general retinal thicknesses of RPD eyes were significantly decreased (95%CI -14.080, -0.655; P=0.032). The vessel densities of DCP in RPD eyes were significantly increased in the global (95%CI 1.067, 7.312; P=0.027), parafoveal (95%CI 0.417, 5.241; P=0.022), and perifoveal (95%CI 0.181, 6.842; P=0.039) quadrants. However, the vessel densities of the SCP were rarely increased in the eyes with RPD. CONCLUSION: The thinning of retinas in the RPD group suggests a reduction in the number of cells. Additionally, the increased vessel density of the DCP in retinas with RPD indicates a greater demand for blood supply, possibly due to the hypoxia induced RPD compensation caused by RPD in the outer retina. This study highlights the pathological risks associated with RPD and emphasizes the importance of early intervention to retard the progression of AMD.
18 July 2024 in International Journal of Ophthalmology
AIM: To evaluate the trending visual performance of different intraocular lenses (IOLs) over time after implantation. METHODS: Ninety-one patients received cataract surgery with implantations of monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs, and extended-depth-of-focus (EDoF) IOLs were included. The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared. RESULTS: Most of the visual parameters improved over the postoperative 6mo. The postoperative visual acuity (POVA) of the Mon IOL, SegRef IOL, and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group. Nevertheless, the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo. The optical quality initially improved in the EDoF IOL group, then in the Mon IOL, SegRef IOL, and Dif IOL groups. POVA and objective visual performance of the Mon IOL and EDoF IOL groups, as well as POVA and visual quality of the Dif IOL group, improved in the postoperative 1mo and stabilized. Within the postoperative 6mo, gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group, as well as in the postoperative optical quality of the Dif IOL group. CONCLUSION: The visual performance is different among eyes implanted with different IOLs. The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.