Huanxin Zhang

Dr. Huanxin Zhang

Lab of space environment exploration, National Space Science Center, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2024 in Aerospace
Verified
Journal Article
Open access
PDF file
LWLiping Wang
Liping Wang
GSGuohong Shen
Guohong Shen
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
DHDonghui Hou
Donghui Hou
SZShenyi Zhang
Shenyi Zhang
YSYing Sun
Ying Sun
Particle radiation on the Moon is influenced by a combination of galactic cosmic rays, high-energy solar particles, and secondary particles interacting on the lunar surface. When China’s Chang’e-7 lander lands at the Moon’s South Pole, it will encounter this complex radiation environment. Therefore, a payload detection technology was developed to comprehensively measure the energy spectrum, direction, and radiation effects of medium- and high-energy charged particles on the lunar surface. During the ground development phase, the payload performance was tested against the design specifications. The verification results indicate that the energy measurement ranges are 30 keV to 300 MeV for protons, 30 keV to 12 MeV for electrons, and 8 to 400 MeV/n for heavy ions. The energy resolution is 10.81% for 200 keV electrons of the system facing the lunar surface; the dose rate measurement sensitivity is 7.48 µrad(Si)/h; and the LET spectrum measurement range extends from 0.001 to 37.014 MeV/(mg/cm2). These comprehensive measurements are instrumental in establishing a lunar surface particle radiation model, enhancing the understanding of the lunar radiation environment, and supporting human lunar activities.

22 March 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
XZXiaoxin Zhang
Xiaoxin Zhang
JWJinhua Wang
Jinhua Wang
CHCong Huang
Cong Huang
JLJiawei Li
Jiawei Li
PZPengfei Zhang
Pengfei Zhang
This article introduces the instrument design of the medium energy proton detector (energy range: 30 keV–5 MeV) mounted on the FY-3E satellite. Through the design and optimization of the sensor signal processing circuit, the anti-electromagnetic interference ability of the medium energy particle detector is greatly enhanced. The designed aluminum plating on sensors can effectively exclude the light pollution to the medium energy protons. The designed permanent annular magnet has a deflection efficiency of more than 95% for medium energy electrons below 1.0 MeV. Additionally, by designing the logical working mode of the sensor, the contamination by other high energy particles (high energy electrons > 1.5 MeV, high energy protons > 5 MeV, and heavy ions) is excluded. Combining the above methods, the detector achieves the detection lower limit of 30 keV for medium energy protons. Its energy resolution is better than 15%@100 keV and the mixing ratio of electrons is less than 2%.

24 March 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
YSYing Sun
Ying Sun
BZBinquan ZHANG
Binquan ZHANG
XZXiaoxin Zhang
Xiaoxin Zhang
GSGuohong Shen
Guohong Shen
TJTao Jing
Tao Jing
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
The radiation damage effect is relatively serious during spacecraft operation in orbit. To know the real cumulative dose in orbit accurately, a radiation dose detector is carried on the FY-4B satellite. It comprises one electric control unit and three dose detectors, with a total of four payloads. Each dose detector includes five dose-monitoring points corresponding to different shielding thicknesses, which are mainly used for the measurement of the dose depth. Three dose detectors with the same function are installed in the X, Y and Z positions and can detect the total dose in different directions during the operation of the satellite. Each detector has the characteristics of small size, high integration and low power consumption. At present, the FY-4B satellite is in orbit. The detectors have been working normally since they were started up, and good preliminary detection results have been obtained. From the power-up of the detectors to April 2022, the maximum dose has reached 2.7 × 103 rad(Si). We conducted a preliminary analysis of the relationship between total dose and shielding thickness. In addition, the relationship between daily average dose and shielding thickness was further analyzed. These studies have application value for radiation protection design.

12 June 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
GSGuohong Shen
Guohong Shen
ZCZheng Chang
Zheng Chang
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
CWChunqin Wang
Chunqin Wang
YSYing Sun
Ying Sun
YSYueqiang Sun
Yueqiang Sun
Based on the characteristics of space particle radiation in the Sun-synchronous orbit (SSO), a space particle radiation effect comprehensive measuring instrument (SPRECMI) was installed on the orbital platform of the upper stage of the Chinese CZ-4C carrier rocket, which can acquire the high-energy proton energy spectra, linear energy transfer (LET) spectra of particles, and radiation dose rate. The particle radiation detection data were obtained at 1000 km altitude for the first time, which can be used mainly for scientific research of the space environment, in-orbit fault analysis, and the operational control management of spacecraft, and can also serve as reference data for component validation tests. After SPRECMI’s development, accelerator calibration and simulations were conducted, and the results demonstrated that all the measured indicators, including the high-energy proton spectra (energy range: 21.8–275.0 MeV, precision: 37.2 MeV/(mg/cm2)), met the relevant requirements. Furthermore, the in-orbit flight test revealed that the detection results of the load components were consistent with the physical characteristics of the particle radiation environment of the spacecraft’s orbit.

1 January 2023 in Open Astronomy
Verified
Journal Article
Open access
PDF file
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
GSGuohong Shen
Guohong Shen
SZShenyi Zhang
Shenyi Zhang
LQLin Quan
Lin Quan
CTChao Tian
Chao Tian
WJWentao Ji
Wentao Ji
This work introduces the instruments’ design of multi-directional medium-energy electron detector (energy range: 30–770 keV) and high-energy electron detector (energy range: 400 keV to 5.8 MeV) deployed on one of the BeiDou navigation satellites in medium earth orbit. Through the electromagnetic compatibility design, the problem of the detector signal being susceptible to electromagnetic interference is solved and the lower detection limit reaches a very low level of 20 keV. The proton contamination in the electron measurement can be effectively removed by designing the light-blocking layer and the logical working mode of the sensors. The detector circuits and sensor structure are optimized and the miniaturization of the instrument is realized. This study also introduces the calibration method of the detectors, and gives the ground test results, which can provide a basis for the on-orbit calibration and data processing of the instrument.

5 December 2024 in Aerospace
Verified
Journal Article
Open access
PDF file
Huanxin ZhangHuanxin Zhang
Huanxin Zhang
GSGuohong Shen
Guohong Shen
DHDonghui Hou
Donghui Hou
SZShenyi Zhang
Shenyi Zhang
CWChunqin Wang
Chunqin Wang
JLJiajie Liao
Jiajie Liao
This article introduces the design and development of a space environment monitoring unit embedded in the versatile experimental assembly for electronic components outside the China space station’s Wentian laboratory cabin module. A newly designed comprehensive detection system is being used for the first time in this kind of detector. The sensor head of the instrument includes a silicon telescope (composed of two silicon semiconductors) for measuring the LET spectrum and radiation dose rate, a typical chip for monitoring a single-event upset, and a CR-39 plastic nuclear track detector for detecting heavy ion tracks. The two silicon sensors stacked up and down are used for measuring the LET spectrum, which ranges from 0.001 to 100 MeV·cm2/mg. A sensor charge allocation method is adopted to divide the detection range into four cascaded levels, each achieving different detection ranges separately and then concatenated together, while traditional detection methods need multiple sets of probes to achieve the same dynamic range. At the same time, using the two sensors mentioned above, the silicon absorption dose rate under two different shielding thicknesses can be obtained through calculation, ranging from 10−5 to 10−1 rad (Si)/h. Multiple calibration methods are applied on the ground. The preliminary in-orbit detection results are provided and compared with the simulation results obtained using the existing space environment model, and we analyze and discuss their differences.