Camilo L.M. Morais

Dr. Camilo L.M. Morais

State University of Ceará, Fortaleza, Ceará, Brazil
Associated Professor

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Nature Protocols
Verified
Journal Article
Open access
PDF file
CMCamilo L.M. Morais
Camilo L.M. Morais
Kássio LimaKássio Lima
Kássio Lima
MSManeesh Singh
Maneesh Singh
FMFrancis L Martin
Francis L Martin
Vibrational spectroscopy techniques, such as Fourier-transform infrared (FTIR) and Raman spectroscopy, have been successful methods for studying the interaction of light with biological materials and facilitating novel cell biology analysis. Spectrochemical analysis is very attractive in disease screening and diagnosis, microbiological studies and forensic and environmental investigations because of its low cost, minimal sample preparation, non-destructive nature and substantially accurate results. However, there is now an urgent need for multivariate classification protocols allowing one to analyze biologically derived spectrochemical data to obtain accurate and reliable results. Multivariate classification comprises discriminant analysis and class-modeling techniques where multiple spectral variables are analyzed in conjunction to distinguish and assign unknown samples to pre-defined groups. The requirement for such protocols is demonstrated by the fact that applications of deep-learning algorithms of complex datasets are being increasingly recognized as critical for extracting important information and visualizing it in a readily interpretable form. Hereby, we have provided a tutorial for multivariate classification analysis of vibrational spectroscopy data (FTIR, Raman and near-IR) highlighting a series of critical steps, such as preprocessing, data selection, feature extraction, classification and model validation. This is an essential aspect toward the construction of a practical spectrochemical analysis model for biological analysis in real-world applications, where fast, accurate and reliable classification models are fundamental.

5 April 2019 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
CMCamilo L.M. Morais
Camilo L.M. Morais
Maria ParaskevaidiMaria Paraskevaidi
Maria Paraskevaidi
LCLi Cui
Li Cui
NFNigel J. Fullwood
Nigel J. Fullwood
MIMartin Isabelle
Martin Isabelle
FMFrancis L Martin
Francis L Martin

5 September 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
Maria ParaskevaidiMaria Paraskevaidi
Maria Paraskevaidi
CMCamilo L.M. Morais
Camilo L.M. Morais
KLKássio M. G. Lima
Kássio M. G. Lima
JSJulie S. Snowden
Julie S. Snowden
JSJennifer A. Saxon
Jennifer A. Saxon
FMFrancis L Martin
Francis L Martin
The progressive aging of the world’s population makes a higher prevalence of neurodegenerative diseases inevitable. The necessity for an accurate, but at the same time, inexpensive and minimally invasive, diagnostic test is urgently required, not only to confirm the presence of the disease but also to discriminate between different types of dementia to provide the appropriate management and treatment. In this study, attenuated total reflection FTIR (ATR-FTIR) spectroscopy combined with chemometric techniques were used to analyze blood plasma samples from our cohort. Blood samples are easily collected by conventional venepuncture, permitting repeated measurements from the same individuals to monitor their progression throughout the years or evaluate any tested drugs. We included 549 individuals: 347 with various neurodegenerative diseases and 202 age-matched healthy individuals. Alzheimer’s disease (AD; n = 164) was identified with 70% sensitivity and specificity, which after the incorporation of apolipoprotein ε4 genotype (APOE ε4) information, increased to 86% when individuals carried one or two alleles of ε4, and to 72% sensitivity and 77% specificity when individuals did not carry ε4 alleles. Early AD cases (n = 14) were identified with 80% sensitivity and 74% specificity. Segregation of AD from dementia with Lewy bodies (DLB; n = 34) was achieved with 90% sensitivity and specificity. Other neurodegenerative diseases, such as frontotemporal dementia (FTD; n = 30), Parkinson’s disease (PD; n = 32), and progressive supranuclear palsy (PSP; n = 31), were included in our cohort for diagnostic purposes. Our method allows for both rapid and robust diagnosis of neurodegeneration and segregation between different dementias. Significance Vibrational spectroscopy is an ideal technique for analysis of biofluids, as it provides a “spectral fingerprint” of all of the molecules present within a biological sample, thus generating a holistic picture of the sample’s status. Neurodegenerative diseases lack early and accurate diagnosis, and tests currently used for their detection are either invasive or expensive and time-consuming. This study used blood plasma to diagnose and differentiate various neurodegenerative diseases; the achieved sensitivities and specificities are equal to, or even higher than, the ones obtained by clinical/molecular methods. Herein, we show that spectroscopy could provide a simple and robust diagnostic test. Additional work should include asymptomatic individuals for an early screening test and exploration of neurodegenerative diseases at all stages of severity.

22 May 2019 in Bioinformatics
Verified
Journal Article
Open access
PDF file
CMCamilo L.M. Morais
Camilo L.M. Morais
MSMarfran C D Santos
Marfran C D Santos
KLKássio M G Lima
Kássio M G Lima
FMFrancis L Martin
Francis L Martin
Motivation: Data splitting is a fundamental step for building classification models with spectral data, especially in biomedical applications. This approach is performed following pre-processing and prior to model construction, and consists of dividing the samples into at least training and test sets; herein, the training set is used for model construction and the test set for model validation. Some of the most-used methodologies for data splitting are the random selection (RS) and the Kennard-Stone (KS) algorithms; here, the former works based on a random splitting process and the latter is based on the calculation of the Euclidian distance between the samples. We propose an algorithm called the Morais-Lima-Martin (MLM) algorithm, as an alternative method to improve data splitting in classification models. MLM is a modification of KS algorithm by adding a random-mutation factor. Results: RS, KS and MLM performance are compared in simulated and six real-world biospectroscopic applications using principal component analysis linear discriminant analysis (PCA-LDA). MLM generated a better predictive performance in comparison with RS and KS algorithms, in particular regarding sensitivity and specificity values. Classification is found to be more well-equilibrated using MLM. RS showed the poorest predictive response, followed by KS which showed good accuracy towards prediction, but relatively unbalanced sensitivities and specificities. These findings demonstrate the potential of this new MLM algorithm as a sample selection method for classification applications in comparison with other regular methods often applied in this type of data. Availability and implementation: MLM algorithm is freely available for MATLAB at https://doi.org/10.6084/m9.figshare.7393517.v1.

4 June 2018 in ACS Chemical Neuroscience
Verified
Journal Article
Closed access
Maria ParaskevaidiMaria Paraskevaidi
Maria Paraskevaidi
CMCamilo L.M. Morais
Camilo L.M. Morais
DHDiane E. Halliwell
Diane E. Halliwell
DMDavid M. A. Mann
David M. A. Mann
DADavid Allsop
David Allsop
FMFrancis L Martin
Francis L Martin

4 June 2018 in The Analyst
Verified
Journal Article
Closed access
PDF file
Maria ParaskevaidiMaria Paraskevaidi
Maria Paraskevaidi
CMCamilo L.M. Morais
Camilo L.M. Morais
Kássio LimaKássio Lima
Kássio Lima
KAKatherine M. Ashton
Katherine M. Ashton
HSHelen F. Stringfellow
Helen F. Stringfellow
FMFrancis L Martin
Francis L Martin
The current lack of an accurate, cost-effective and non-invasive test that would allow for screening and diagnosis of gynaecological carcinomas, such as endometrial and ovarian cancer, signals the necessity for alternative approaches. The potential of spectroscopic techniques in disease investigation and diagnosis has been previously demonstrated. Here, we used attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to analyse urine samples from women with endometrial (n = 10) and ovarian cancer (n = 10), as well as from healthy individuals (n = 10). After applying multivariate analysis and classification algorithms, biomarkers of disease were pointed out and high levels of accuracy were achieved for both endometrial (95% sensitivity, 100% specificity; accuracy: 95%) and ovarian cancer (100% sensitivity, 96.3% specificity; accuracy 100%). The efficacy of this approach, in combination with the non-invasive method for urine collection, suggest a potential diagnostic tool for endometrial and ovarian cancers.