Utpal S. Bhalala

Dr. Utpal S. Bhalala

Department of Pediatrics, Driscoll Children's Hospital, 3533 S Alameda St, Corpus Christi, TX 78411, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2012 in Pediatric Critical Care Medicine
Verified
Journal Article
Closed access
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
ANAkira Nishisaki
Akira Nishisaki
DMDerrick McQueen
Derrick McQueen
GBGeoffrey L. Bird
Geoffrey L. Bird
WMWynne E. Morrison
Wynne E. Morrison
JSJoanne P. Starr
Joanne P. Starr
Near-infrared spectroscopy correlation with low cardiac output has not been validated. Our objective was to determine role of splanchnic and/or renal oxygenation monitoring using near-infrared spectroscopy for detection of low cardiac output in children after surgery for congenital heart defects. Prospective observational study. Pediatric intensive care unit of a tertiary care teaching hospital. Children admitted to the pediatric intensive care unit after surgery for congenital heart defects. None. We hypothesized that splanchnic and/or renal hypoxemia detected by near-infrared spectroscopy is a marker of low cardiac output after pediatric cardiac surgery. Patients admitted after cardiac surgery to the pediatric intensive care unit over a 10-month period underwent serial splanchnic and renal near-infrared spectroscopy measurements until extubation. Baseline near-infrared spectroscopy values were recorded in the first postoperative hour. A near-infrared spectroscopy event was a priori defined as ≥20% drop in splanchnic and/or renal oxygen saturation from baseline during any hour of the study. Low cardiac output was defined as metabolic acidosis (pH 2 mmol/L, or base excess ≤-5), oliguria (urine output <1 mL/kg/hr), or escalation of inotropic support. Receiver operating characteristic analysis was performed using near-infrared spectroscopy event as a diagnostic test for low cardiac output. Twenty children were enrolled: median age was 5 months; median Risk Adjustment for Congenital Heart Surgery category was 3 (1-6); median bypass and cross-clamp times were 120 mins (45-300 mins) and 88 mins (17-157 mins), respectively. Thirty-one episodes of low cardiac output and 273 near-infrared spectroscopy events were observed in 17 patients. The sensitivity and specificity of a near-infrared spectroscopy event as an indicator of low cardiac output were 48% (30%-66%) and 67% (64%-70%), respectively. On receiver operating characteristic analysis, neither splanchnic nor renal near-infrared spectroscopy event had a significant area under the curve for prediction of low cardiac output (area under the curve: splanchnic 0.45 [95% confidence interval 0.30-0.60], renal 0.51 [95% confidence interval 0.37-0.65]). Splanchnic and/or renal hypoxemia as detected by near-infrared spectroscopy may not be an accurate indicator of low cardiac output after surgery for congenital heart defects.

25 February 2021 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PDF file
LSLydia Sumbel
Lydia Sumbel
AWAanchal Wats
Aanchal Wats
MSMohammed Salameh
Mohammed Salameh
EAElumalai Appachi
Elumalai Appachi
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
Objective: Conventional methods of fluid assessment in critically ill children are difficult and/or inaccurate. Impedance cardiography has capability of measuring thoracic fluid content (TFC). There is an insufficient literature reporting correlation between TFC and conventional methods of fluid balance and whether TFC predicts outcomes in critically ill children. We hypothesized that TFC correlates with indices of fluid balance [FIMO (Fluid Intake Minus Output) and AFIMO (Adjusted Fluid Intake Minus Output)] and is a predictor of outcomes in critically ill children.Design: Retrospective chart review.Setting: Pediatric intensive care unit of a tertiary care teaching hospital.Patients: Children <21 years, admitted to our Pediatric Intensive Care Unit (PICU) between July- November 2018 with acute respiratory failure and/or shock and who were monitored for fluid status using ICON® monitor.Interventions: None.Measurements and Main Results: We collected demographic information, data on daily and cumulative fluid balance (CFB), ventilator, PICU and hospital days, occurrence of multi-organ dysfunction syndrome (MODS), and mortality. We calculated AFIMO using insensible fluid loss. We analyzed data using correlation coefficient, chi-square test and multiple linear regression analysis. We analyzed a total 327 recordings of TFC, FIMO and AFIMO as daily records of fluid balance in 61 critically ill children during the study period. The initial TFC, FIMO, and AFIMO in ml [median (IQR)] were 30(23, 44), 300(268, 325), and 21.05(−171.3, 240.2), respectively. The peak TFC, FIMO, and AFIMO in ml were 36(26, 24), 322(286, 334), and 108.8(−143.6, 324.4) respectively. The initial CFB was 1134.2(325.6, 2774.4). TFC did not correlate well with FIMO or AFIMO (correlation coefficient of 0.02 and −0.03, respectively), but a significant proportion of patients with high TFC exhibited pulmonary plethora on x-ray chest (as defined by increased bronchovascular markings and/or presence of pleural effusion) (p = 0.015). The multiple linear regression analysis revealed that initial and peak TFC and peak and mean FIMO and AFIMO predicted outcomes (ventilator days, length of PICU, and hospital days) in critically ill children (p < 0.05).Conclusions: In our cohort of critically ill children with respiratory failure and/or shock, TFC did not correlate with conventional measures of fluid balance (FIMO/AFIMO), but a significant proportion of patients with high TFC had pulmonary plethora on chest x-ray. Both initial and peak TFC predicted outcomes in critically ill children.

28 September 2016 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PDF file
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
EAElumalai Appachi
Elumalai Appachi
MMMuhammad Ali Mumtaz
Muhammad Ali Mumtaz
Many known risk factors for adverse cardiovascular and neurological outcomes in children with congenital heart defects (CHD) are not modifiable, however, the temperature and blood flow during cardiopulmonary bypass (CPB), are two risk factors, which may be altered in an attempt to improve long-term neurological outcomes. Deep hypothermic circulatory arrest (DHCA), traditionally used for aortic arch repair, has been associated with short-term and long-term neurologic sequelae. Therefore, there is a rising interest in using moderate hypothermia with selective antegrade cerebral blood flow on CPB during aortic arch repair. Rewarming from moderate-to-deep hypothermia has been shown to be associated with neuronal injury, neuroinflammation and loss of cerebrovascular autoregulation. A significantly lesser degree of rewarming is required following mild (33-35°C) hypothermia as compared to moderate (28-32°C), deep (21–27°C) and profound (less than 20°C) hypothermia. Therefore, we believe that mild hypothermia is associated with a lower risk of rewarming-induced neurologic injury. We hypothesize that mild hypothermia with selective antegrade cerebral perfusion during CPB for neonatal aortic arch repair would be associated with improved neurologic outcome.

9 March 2022 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PPPratik Parikh
Pratik Parikh
RSRavi Samraj
Ravi Samraj
HOHenry Ogbeifun
Henry Ogbeifun
LSLydia Sumbel
Lydia Sumbel
KBKelli Brimager
Kelli Brimager
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
Introduction: American Heart Association guidelines recommend the use of feedback devices for CPR provider resuscitation training. There is paucity of published literature regarding the utility of these devices especially in neonates and infants. We sought to evaluate if simulation-based education and debriefing using a CPR feedback device would improve CPR performance on an infant manikin in a cohort of NICU nurses as evaluated by CPR feedback device.Methods: We conducted a prospective, observational simulation study to assess the quality of chest compressions by NICU nurses before and after debriefing using CPR quality data captured by an accelerometer-based device. Chest compression (CC) depth, rate, recoil, CC fraction and nursing confidence level related to performing a high-quality CPR were compared before and after debriefing using paired t-test and Wilcoxon rank sum test.Results: A total of 62 NICU nurses participated in the study and all of them were Neonatal Resuscitation Program (NRP) certified. There was a significant improvement in CC depth and CC fraction [mean + SD values = 0.79 in + 0.17 (pre-debrief), 0.86 in + 0.21 (post-debrief) (p = 0.034) and 56.8% + 17.7 (pre-debrief), 70.8% + 18.4 (post-debrief) (0.0014), respectively]. There was no difference in CC rate (p = 0.36) and recoil (p = 0.25) between pre and post structured debriefing. The confidence level of nurses in all CPR dynamics (appropriate CC rate, CC depth, team communication, minimizing interruption in CC and coordinating CC with ventilation) was significantly higher after simulation and structured debriefing. All the nurses used 3:1 compression: ventilation ratio of NRP despite the patient being a 4 month old premature baby in the NICU.Conclusions: Simulation training and debriefing of NICU nurses using CPR feedback device improved their chest compression quality on an infant mannequin and their confidence level for performing high-quality CPR. NICU providers tend to use NRP protocol of 3:1 compression: ventilation ratio during CPR in the NICU irrespective of age of the infant.

7 April 2022 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PAPranali Awadhare
Pranali Awadhare
RPRadha Patel
Radha Patel
TMTracy McCallin
Tracy McCallin
KMKiran Mainali
Kiran Mainali
KJKelly Jackson
Kelly Jackson
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
Introduction: The assessment of fluid responsiveness is important in the management of shock but conventional methods of assessing fluid responsiveness are often inaccurate. Our study aims to evaluate changes in objective hemodynamic parameters as measured using electrical cardiometry (ICON® monitor) following the fluid bolus in children presenting with shock and to evaluate whether any specific hemodynamic parameter can best predict fluid responsiveness among children with shock.Materials and Methods: We conducted a prospective observational study in children presenting with shock to our emergency department between June 2020 and March 2021. We collected the parameters such as heart rate (HR), respiratory rate (RR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and hemodynamic data such as cardiac output CO), cardiac index (CI), index of contractility (ICON), stroke volume (SV), stroke index (SI), corrected flow time (FTC), systolic time ratio (STR), variation of index of contractility (VIC), stroke volume variation (SVV), systemic vascular resistance (SVR), and thoracic fluid content (TFC) using the ICON monitor before and after fluid bolus (FB). We assessed percent change (Δ) and used paired-sample Student’s t-test to compare pre- and post-hemodynamic data and Mann–Whitney U-test to compare fluid responders and non-responders. P-Values < 0.05 were considered statistically significant.Results: We recorded 42 fluid interventions in 40 patients during our study period. The median IQR age was 10.56 (4.8, 14.8) years with male/female ratio (1.2:1). There was a significant decrease in ΔRR [−1.61 (−14.8, 0); p = 0.012], ΔDBP [−5.5 (−14.4, 8); p = 0.027], ΔMAP [−2.2 (−11, 2); p = 0.018], ΔSVR [−5.8 (−20, 5.2); p = 0.025], and ΔSTR [−8.39 (−21, 3); p = 0.001] and significant increase in ΔTFC [6.2 (3.5, 11.4); p = 0.01] following FB. We defined fluid responders by an increase in SV by ≥10% after a single FB of 20 ml/kg crystalloid. Receiver operating curve analysis revealed that among all the parameters, 15% change in ICON had an excellent AUC (0.85) for the fluid responsiveness.Conclusion: Our study showed significant changes in objective hemodynamic parameters, such as SVR, STR, and TFC following FB in children presenting with shock. A 15% change in ICON had an excellent predictive performance for the fluid responsiveness among our cohort of pediatric shock.

28 May 2018 in Frontiers in Pediatrics
Verified
Journal Article
Open access
PDF file
Utpal S. BhalalaUtpal S. Bhalala
Utpal S. Bhalala
ABArun Bansal
Arun Bansal
KCKrishan Chugh
Krishan Chugh
Over last 2 decades, there has been a significant progress made in the field of pediatric critical care in India. There has been complementary and parallel growth in the pediatric critical care services in India and the number of pediatric critical care providers who are either formally trained in India or who have returned to India after their formal training abroad. The pediatric critical care community in India has recognized obvious differences in profiles of critical illnesses and patients between Indian subcontinent and the West. Therefore there is a growing interest in generating scientific evidence through local research which would be applicable to critically ill children in Indian subcontinent. This article focuses on advances in pediatric critical care research in India and its future directions.