A large proportion of building energy consumption in tropical countries like Thailand primarily comes from air conditioning systems used to maintain the comfort level of building occupants. This paper aims to evaluate the performance of an alternative cooling system based on the evaporative principle in terms of thermal characteristics and energy consumption. A simulation model using computational fluid dynamics (CFD) software ANSYS version 16.0 and an actual experimental setup at the laboratory level were built to verify the results of the proposed cooling system. Additionally, factors that influence performance, such as components of the building envelope and the building’s orientation, are considered. This research aims to demonstrate the impact of building envelope material and building characteristics on the energy usage in air conditioning systems and to propose an energy-efficient cooling system. The results demonstrate that the proposed cooling system can reduce the temperature inside the building. However, the characteristics of the building also affect the energy performance. Thus, the proposed cooling system, in combination with an efficient envelope material, can achieve energy savings of around 35–43%. Therefore, a combination of the proposed cooling system and optimal building design can ensure comfort for building occupants while saving energy.
Bottled-beverage production systems require considerable machinery and sophisticated control systems. A malfunction in the production system can result in machine stoppages, thereby decreasing productivity and resulting in the production output not meeting the required target. Therefore, the problem of frequent stoppages of the production system must be resolved. The ‘Fast Restart Function’ is a proposed feature that can help reduce machine downtime by decreasing the time required for the product to drain from the conveyor. In this study, using this strategy, the investigated manufacturing system’s efficiency increased from 86.81% to 90.29%, enabling an increase in the average production capacity by 27,187 bottles per day, i.e., a 3.48 percent increment of the daily capacity. When employed in inefficient production systems or systems facing frequent shutdowns, this system is of considerable value for mitigating production stoppages.
A major challenge in distribution systems is the issue of voltage drop along the distribution line resulting from an increased load capacity connected to the utility. A significant voltage drop can affect the performance of a distribution system and cause quality issues for end users, impacting the system’s long-term sustainability and reliability. Therefore, regulations have been set stating that the voltage level should not be more that 5% higher or lower than the rated voltage. Thus, in this study, we aimed to evaluate the voltage level characteristics of a 22 kV distribution system that replicates the actual distribution system in the Provincial Electricity Authority. A voltage improvement technique based on distributed generation placement was proposed. In addition, the distribution system characteristics with and without distributed generation placement were evaluated under fault conditions. The results indicate that distributed generation placement in the distribution system can improve the voltage level along the distribution line. However, the level of increase in voltage depends on the size of the load, the capacity of the distributed generation, and the location of the distributed generation system on the distribution line. Furthermore, placing a distributed generation system with a minimum capacity at the proposed location can improve the voltage within the utility’s standard level. Thus, the installation of a distributed generation system in the distribution system is beneficial in terms of voltage improvement in the distribution system and provides the power system with a sustainable method to address the issue of voltage drop.