Saniye Söylemez

Prof. Saniye Söylemez

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
HCHurija Dzudzevic Cancar
Hurija Dzudzevic Cancar
SSSaniye Söylemez
Saniye Söylemez
YAYeliz Akpinar
Yeliz Akpinar
MKMelis Kesik
Melis Kesik
SGSeza Göker
Seza Göker
LTLevent Toppare
Levent Toppare

1 June 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
SSSaniye Söylemez
Saniye Söylemez
YUYasemin A. Udum
Yasemin A. Udum
MKMelis Kesik
Melis Kesik
CHCevher Gündoğdu Hızlıateş
Cevher Gündoğdu Hızlıateş
YEYavuz Ergun
Yavuz Ergun
LTLevent Toppare
Levent Toppare


3 October 2014 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SSSaniye Söylemez
Saniye Söylemez
SHSerife O. Hacioglu
Serife O. Hacioglu
MKMelis Kesik
Melis Kesik
HUHande Unay
Hande Unay
ACAli Cirpan
Ali Cirpan
LTLevent Toppare
Levent Toppare

15 July 2014 in Polymer Chemistry
Verified
Journal Article
Closed access
PDF file
MKMelis Kesik
Melis Kesik
HAHuseyin Akbulut
Huseyin Akbulut
SSSaniye Söylemez
Saniye Söylemez
ŞCŞevki Can Cevher
Şevki Can Cevher
GHGönül Hızalan
Gönül Hızalan
LTLevent Toppare
Levent Toppare
A novel approach for the fabrication of a biosensor from a conducting polymer bearing polypeptide segments and ferrocene moieties is reported. The approach involves the electrochemical copolymerization of the electroactive polypeptide macromonomer and independently prepared ferrocene imidazole derivative of dithiophene, on the electrode surface. The polypeptide macromonomer was synthesized by the simultaneous formation of N-carboxyanhydride (NCA) and ring opening polymerization of N-Boc-L-lysine (α-amino acid of the corresponding NCA) using an amino functional bis-EDOT derivative (BEDOA-6) as an initiator. Alcohol oxidase was then covalently immobilized onto the copolymer coated electrode using glutaraldehyde as the crosslinking agent. The intermediates and final conducting copolymer before and after enzyme immobilization were fully characterized by FT-IR, 1H-NMR, GPC, cyclic voltammetry, SEM and EIS analyses. The newly designed biosensor which combined the advantages of each component was tested as an ethanol sensing system offering fast response time (9 s), wide linear range (0.17 mM and 4.25 mM) and low detection limit (0.28 mM) with a high sensitivity (12.52 μA mM−1 cm−2). Kinetic parameters Kapp M and Imax were 2.67 mM and 2.98 μA, respectively. The capability of the biosensor in determining ethanol content in alcoholic beverages was also demonstrated.

1 June 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JTJanset Turan
Janset Turan
MKMelis Kesik
Melis Kesik
SSSaniye Söylemez
Saniye Söylemez
SGSeza Goker
Seza Goker
SCSahin Coskun
Sahin Coskun
LTLevent Toppare
Levent Toppare