Carina Thomas

Mrs. Carina Thomas

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2025 in Biomechanics
Verified
Journal Article
Open access
PDF file
CTCarina Thomas
Carina Thomas
KNKevin Nolte
Kevin Nolte
MSMarcus Schmidt
Marcus Schmidt
TJThomas Jaitner
Thomas Jaitner
Background: Marker-based motion capture systems are commonly used for three-dimensional movement analysis in sports. Novel, markerless motion capture systems enable the collection of comparable data under more time-efficient conditions with higher flexibility and fewer restrictions for the athletes during movement execution. Studies show comparable results between markerless and marker-based systems for kinematics of the lower extremities, especially for walking gait. For more complex movements, such as throwing, limited data on the agreement of markerless and marker-based systems is available. The aim of this study is to compare the outcome of a video-based markerless motion capture system with a marker-based approach during an artificial basketball-throwing task. Methods: Thirteen subjects performed five simulated basketball throws under laboratory conditions, and were recorded simultaneously with the marker-based measurement system, as well as two versions of a markerless measurement system (differing in their release date). Knee, hip, shoulder, elbow and wrist joint angles were acquired and root mean square distance (RMSD) was calculated for all subjects, parameters and attempts. Results: The RMSD of all joint angles of the marker-based and markerless systems ranged from 7.17° ± 3.88° to 26.66° ± 14.77° depended on the joint. The newest version of the markerless system showed lower RMSD values compared to the older version, with an RMSD of 16.68 ± 5.03° for elbow flexion, capturing 93.84% of the data’s RMSD of 22.22 ± 5.52, accounting for 87.69% of the data. While both versions showed similar results for right knee flexion, lower differences were observed in the new version for right hip flexion, with an RMSD of 8.17 ± 3.75 compared to the older version’s 13.24 ± 5.78. Additionally, the new version demonstrated lower RMSD values for right hand flexion. Conclusions: Overall, the new version of the markerless system showed lower RMSD values across various joint angles during throwing movement analysis compared to the older version. However, the differences between markerless and marker-based systems are especially large for the upper extremities. In conclusion, it is not clearly explainable if the detected inter-system differences are due to inaccuracies of one system or the other, or a combination of both, as both methodologies possess special limitations (soft tissue vibration or joint center position accuracy). Further investigations are needed to clarify the accordance between markerless and marker-based motion capture systems during complex movements.

1 February 2023 in Biomechanics
Verified
Journal Article
Open access
PDF file
CTCarina Thomas
Carina Thomas
KNKevin Nolte
Kevin Nolte
MSMarcus Schmidt
Marcus Schmidt
TJThomas Jaitner
Thomas Jaitner
Children have different anthropometrical size ratios in relation to ball and basket compared to adults, but usually compete on the same basket height and field. Therefore, they have to adapt their throwing technique, which might result in movement patterns unfavorable for long-term performance development. In this study, we analyze how children adapt their throwing techniques to different conditions. Seven basketball players (10.14 ± 1.12 years) completed a total of 60 throws, combining different ball sizes, basket heights, and distances. The throwing movements were captured by a 3D motion capture system. Accumulated distances between all time courses of angles, angular accelerations, and velocities served as similarity measures and were analyzed by cluster analysis, including purity measures. Considering all throws, a division into seven clusters separated each individual. For all subjects, distances accounted for the most changes in the throwing motion (purity 0.81–1). In the subclusters, the basket heights were not a decisive condition (purity 0.42–0.63). However, an increase in purity was found compared to the main clusters. Children seem to adapt their movement behavior primarily to throwing distances and subordinately to basket heights, which indicates that changing playing conditions (e.g., closer 3-point line, lower baskets) might be beneficial in mini-basketball.