Takafumi Nakano

Dr. Takafumi Nakano

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2020 in Nature
Verified
Journal Article
Closed access
PDF file
HTHanshen Tsai
Hanshen Tsai
THTomoya Higo
Tomoya Higo
KKKouta Kondou
Kouta Kondou
TNTakuya Nomoto
Takuya Nomoto
ASAkito Sakai
Akito Sakai
SNSatoru Nakatsuji
Satoru Nakatsuji

22 November 2021 in Applied Physics Express
Verified
Journal Article
Open access
MOMikihiko Oogane
Mikihiko Oogane
KFKosuke Fujiwara
Kosuke Fujiwara
AKAkitake Kanno
Akitake Kanno
TNTakafumi Nakano
Takafumi Nakano
HWHiroshi Wagatsuma
Hiroshi Wagatsuma
YAYasuo Ando
Yasuo Ando
We developed tunnel magneto-resistive (TMR) sensors based on magnetic tunnel junctions (MTJs) that are able to detect a weak, sub-pT, magnetic field at a low frequency. Small detectivities of 0.94 pT/Hz1/2 at 1 Hz and 0.05 pT/Hz1/2 at 1 kHz were achieved by lowering the resistance of MTJs and enhancement of the signal using a thick CoFeSiB layer and magnetic flux concentrators. We demonstrated real-time measurement of magnetocardiography (MCG) and nuclear magnetic resonance (NMR) of protons using developed sensors. This result shows that both MCG and NMR can be measured by the same measurement system with ultra-sensitive TMR sensors.

26 May 2020 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MDMaciej Dąbrowski
Maciej Dąbrowski
TNTakafumi Nakano
Takafumi Nakano
DBDavid M. Burn
David M. Burn
AFAndreas Frisk
Andreas Frisk
DNDavid G. Newman
David G. Newman
RHRobert J. Hicken
Robert J. Hicken
Insulating antiferromagnets have recently emerged as efficient and robust conductors of spin current. Element-specific and phase-resolved x-ray ferromagnetic resonance has been used to probe the injection and transmission of ac spin current through thin epitaxial NiO(001) layers. The spin current is found to be mediated by coherent evanescent spin waves of GHz frequency, rather than propagating magnons of THz frequency, paving the way towards coherent control of the phase and amplitude of spin currents within an antiferromagnetic insulator at room temperature.

6 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KKKoshi Kurashima
Koshi Kurashima
MKMAKOTO KATAOKA
MAKOTO KATAOKA
TNTakafumi Nakano
Takafumi Nakano
KFKosuke Fujiwara
Kosuke Fujiwara
SKSeiichi Kato
Seiichi Kato
HMHidenori Mochizuki
Hidenori Mochizuki
A magnetocardiograph that enables the clear observation of heart magnetic field mappings without magnetically shielded rooms at room temperatures has been successfully manufactured. Compared to widespread electrocardiographs, magnetocardiographs commonly have a higher spatial resolution, which is expected to lead to early diagnoses of ischemic heart disease and high diagnostic accuracy of ventricular arrhythmia, which involves the risk of sudden death. However, as the conventional superconducting quantum interference device (SQUID) magnetocardiographs require large magnetically shielded rooms and huge running costs to cool the SQUID sensors, magnetocardiography is still unfamiliar technology. Here, in order to achieve the heart field detectivity of 1.0 pT without magnetically shielded rooms and enough magnetocardiography accuracy, we aimed to improve the detectivity of tunneling magnetoresistance (TMR) sensors and to decrease the environmental and sensor noises with a mathematical algorithm. The magnetic detectivity of the TMR sensors was confirmed to be 14.1 pTrms on average in the frequency band between 0.2 and 100 Hz in uncooled states, thanks to the original multilayer structure and the innovative pattern of free layers. By constructing a sensor array using 288 TMR sensors and applying the mathematical magnetic shield technology of signal space separation (SSS), we confirmed that SSS reduces the environmental magnetic noise by −73 dB, which overtakes the general triple magnetically shielded rooms. Moreover, applying digital processing that combined the signal average of heart magnetic fields for one minute and the projection operation, we succeeded in reducing the sensor noise by about −23 dB. The heart magnetic field resolution measured on a subject in a laboratory in an office building was 0.99 pTrms and obtained magnetocardiograms and current arrow maps as clear as the SQUID magnetocardiograph does in the QRS and ST segments. Upon utilizing its superior spatial resolution, this magnetocardiograph has the potential to be an important tool for the early diagnosis of ischemic heart disease and the risk management of sudden death triggered by ventricular arrhythmia.

20 September 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LHL. Huang
L. Huang
ZYZ. H. Yuan
Z. H. Yuan
BTB. S. Tao
B. S. Tao
CWC. H. Wan
C. H. Wan
PGP. Guo
P. Guo
XHXiufeng Han
Xiufeng Han
The voltage noise characteristic and sensitivity of magnetic tunnel junction sensors are crucial for ultralow field detection. In this work, we used a soft magnetic material electrode Co70.5Fe4.5Si15B10 as a sensing layer to improve the sensitivity. Then, a bias field along the easy axis of a free layer was applied to improve the linearity and manipulate the sensitivity of magnetic tunnel junction sensors. More importantly, random telegraph noise was suppressed by the bias field, resulting in hysteresis-free performance. The highest sensitivity of 3.9%/Oe and the best field detectivity of 4.5 nT/√ Hz at 10 Hz without hysteresis have been achieved. The sensors showed excellent performance with CoFeSiB electrodes, indicating that it is an effective way to improve the performance of sensors by introducing the bias field.

2 January 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TNTakafumi Nakano
Takafumi Nakano
MOM. Oogane
M. Oogane
TFT. Furuichi
T. Furuichi
YAY. Ando
Y. Ando
We developed CoFeB/MgO/CoFeB magnetic tunnel junctions (MTJs) with a perpendicularly magnetized synthetic antiferromagnetic (p-SAF) reference layer for magnetic sensor applications. The MTJs exhibited linear tunnel magnetoresistance curves to out-of-plane applied magnetic fields with dynamic ranges more than ±2.5 kOe, which are wider than those in CoFeB/MgO/CoFeB-MTJs reported to date. The performance metrics of MTJ sensors, i.e., sensitivity and nonlinearity, depend significantly on the anisotropy field of the free layer. We explained the dependences by a simple model based on the Stoner-Wohlfarth and Slonczewski models, which gives us a guideline to design the sensor performance metrics. These findings demonstrated that MTJs with a p-SAF reference layer are promising candidates for wide-dynamic-range magnetic sensors.