Tae Jung Park

Prof. Tae Jung Park


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2010 in Electroanalysis
Verified
Journal Article
Open access
PDF file
MYMin Ho Yang
Min Ho Yang
BCBong Gill Choi
Bong Gill Choi
HPHoSeok Park
HoSeok Park
WHWon Hi Hong
Won Hi Hong
SLSang Yup Lee
Sang Yup Lee
TPTae Jung Park
Tae Jung Park
Nanohybrids of chemically modified graphene (CMG) and ionic liquid (IL) were prepared by sonication to modify the electrode. The modified CMG-IL electrodes showed a higher current and smaller peak-to-peak potential separation than a bare electrode due to the promoted electron transfer rate. Furthermore, the glucose oxidase (GOx) immobilized on the modified electrode displayed direct electron transfer rate and symmetrical redox potentials with a linear relationship at different scan rates. The fabricated GOx/CMG-IL electrodes were developed selective glucose biosensor with respect to a sensitivity of 0.64 μA mM−1, detection limit of 0.376 mM, and response time of <5 s.

1 January 2012 in Talanta
Verified
Journal Article
Closed access
TPTae Jung Park
Tae Jung Park
SLSeok Jae Lee
Seok Jae Lee
DKDo-Kyun Kim
Do-Kyun Kim
NHNam Su Heo
Nam Su Heo
JPJung Youn Park
Jung Youn Park
SLSang Yup Lee
Sang Yup Lee

25 October 2010 in Nanoscale
Verified
Journal Article
Closed access
PDF file
BCBong Gill Choi
Bong Gill Choi
HPHoSeok Park
HoSeok Park
MYMin Ho Yang
Min Ho Yang
Young Mee JungYoung Mee Jung
Young Mee Jung
SLSang Yup Lee
Sang Yup Lee
TPTae Jung Park
Tae Jung Park
Graphene sheets have the potential for practical applications in electrochemical devices, but their development has been impeded by critical problems with aggregation of graphene sheets. Here, we demonstrated a facile and bottom-up approach for fabrication of DNA sensor device using water-soluble sulfonated reduced graphene oxide (SRGO) sheets via microwave-assisted sulfonation (MAS), showing enhanced sensitivity, reliability, and low detection limit. Key to achieving these performances is the fabrication of the SRGOs, where the MAS method enabled SRGOs to be highly dispersed in water (10 mg mL−1) due to the acidic sulfonated groups generated within 3 min of the functionalization reaction. The water-soluble SRGO-DNA (SRGOD) hybrids prepared by electrostatic interactions between a flat single layer of graphene sheets and DNAs are suitable for fabrication of electrical DNA sensor devices because of the unique electrical characteristics of SRGODs. The high sensing performance of SRGOD sensors was demonstrated with detection of DNA hybridization using complementary DNAs, single base mismatched DNAs, and noncomplementary DNAs, with results showing higher sensitivity and lower detection limit than those of reduced graphene oxide-based DNA sensors. Simple and easy fabrication of DNA sensor devices using SRGODs is expected to provide an effective way for electrical detection of DNA hybridization using miniature sensors without the labor-intensive labeling of the sensor and complex measurement equipment.

17 February 2011 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
MYMin Ho Yang
Min Ho Yang
BCBong Gill Choi
Bong Gill Choi
HPHoSeok Park
HoSeok Park
TPTae Jung Park
Tae Jung Park
WHWon Hi Hong
Won Hi Hong
SLSang Yup Lee
Sang Yup Lee

1 March 2010 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
YHYun Suk Huh
Yun Suk Huh
CJChang-Moon Jeong
Chang-Moon Jeong
HCHo Nam Chang
Ho Nam Chang
SLSang Yup Lee
Sang Yup Lee
WHWon Hi Hong
Won Hi Hong
TPTae Jung Park
Tae Jung Park
A protein separation technology using the microfluidic device was developed for the more rapid and effective analysis of target protein. This microfluidic separation system was carried out using the aqueous two-phase system (ATPS) and the ionic liquid two-phase system (ILTPS) for purification method of the protein sample, and the three-flow desalting system was used for the removal of salts from the sucrose-rich sample. Partitioning of the protein sample was observed in ATPS or ILTPS with the various pHs. The microdialysis system was applied to remove small molecules, such as sucrose and salts in the microfluidic channel with the different flow rates of buffer phase. A complex purification method, which combines microdialysis and ATPS or ILTPS, was carried out for the effective purification of bacteriorhodopsin (BR) from the purple membrane of Halobacterium salinarium, which was then analyzed by sodium dodecyl sulfatepolyacrylamide gel electrophoresis and matrix-assisted laser desorption/ionization time-of-flight. Furthermore, we were able to make a stable three-phase flow controlling the flow rate in the microfluidic channel. Our complex purification methods were successful in purifying and recovering the BR to its required value.

3 June 2011 in Nanoscale
Verified
Journal Article
Closed access
PDF file
MYMinHo Yang
MinHo Yang
BCBong Gill Choi
Bong Gill Choi
TPTae Jung Park
Tae Jung Park
NHNam Su Heo
Nam Su Heo
WHWon Hi Hong
Won Hi Hong
SLSang Yup Lee
Sang Yup Lee
The effective and strong immobilization of enzymes on solid surfaces is required for current biological applications, such as microchips, biofuel cells, and biosensors. Gold-binding polypeptide (GBP), a genetically designed peptide, possesses unique and specific interactions with a gold surface, resulting in improved enzyme stability and activity. Herein we demonstrated an immobilization method for biosensor applications through site-specific interactions between GBP-fused organophosphorus hydrolase (GBP-OPH) and gold nanoparticle-coated chemically modified graphene (Au-CMG), showing enhanced sensing capability. A flow injection biosensor was fabricated by using GBP-OPH/Au-CMG to detect paraoxons, a model pesticide, showing higher sensitivity, lower detection limit and better operating stability compared that of OPH/Au-CMG. This strategy, which integrates biotic and abiotic moieties through site-specific interactions, has a great potential for use in biosensing and bioconversion process.