Dario Carugo

Dr. Dario Carugo

Department of Pharmaceutics, University College London
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2016 in Scientific Reports
Verified
Journal Article
Open access
Dario CarugoDario Carugo
Dario Carugo
EBElisabetta Bottaro
Elisabetta Bottaro
JOJoshua Owen
Joshua Owen
ESEleanor Stride
Eleanor Stride
Claudio NastruzziClaudio Nastruzzi
Claudio Nastruzzi
This paper provides an analysis of microfluidic techniques for the production of nanoscale lipid-based vesicular systems. In particular we focus on the key issues associated with the microfluidic production of liposomes. These include, but are not limited to, the role of lipid formulation, lipid concentration, residual amount of solvent, production method (including microchannel architecture), and drug loading in determining liposome characteristics. Furthermore, we propose microfluidic architectures for the mass production of liposomes with a view to potential industrial translation of this technology.

1 November 2013 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
LCLorenzo Capretto
Lorenzo Capretto
Dario CarugoDario Carugo
Dario Carugo
SMStefania Mazzitelli
Stefania Mazzitelli
Claudio NastruzziClaudio Nastruzzi
Claudio Nastruzzi
XZXunli Zhang
Xunli Zhang

31 May 2023 in Nature Reviews Microbiology
Verified
Journal Article
Closed access
PDF file
VCVictor Choi
Victor Choi
JRJennifer L. Rohn
Jennifer L. Rohn
PSPaul Stoodley
Paul Stoodley
Dario CarugoDario Carugo
Dario Carugo
ESEleanor Stride
Eleanor Stride

10 April 2018 in Current Urology Reports
Verified
Journal Article
Open access
PDF file
AMAli Mosayyebi
Ali Mosayyebi
CMCostantino Manes
Costantino Manes
Dario CarugoDario Carugo
Dario Carugo
BSBhaskar K Somani
Bhaskar K Somani
Purpose of Review There are three technological parameters that play a key role on the performance of an ideal stent. These are its material, design and surface coating. This article highlights some fundamental developments that took place in these three areas of stent’s technology, in order to contribute to the identification of an ideal stent. Recent Findings In addition to technological developments concerning stent’s material, design and surface coating, the flow dynamic performance of stents has recently attracted increasing attention. Notably, it has been postulated that the local flow field in a stent is correlated with the deposition of crystals and microorganisms. These findings could potentially revolutionise future stent’s designs, and complement developments made on materials and coatings. Summary The most relevant changes in materials, designs and surface coatings of ureteric stents are reviewed in this article. These are described in the context of a specific cause of stent’s failure they aim to address, with a particular focus on encrustation and biofilm formation.

11 August 2015 in Advanced Materials
Verified
Journal Article
Open access
PDF file
JLJeong Yu Lee
Jeong Yu Lee
Dario CarugoDario Carugo
Dario Carugo
CCCalum Crake
Calum Crake
JOJoshua Owen
Joshua Owen
MVMarie de Saint Victor
Marie de Saint Victor
ESEleanor Stride
Eleanor Stride
A new formulation of volatile nanodroplets stabilized by a protein and polymer coating and loaded with magnetic nanoparticles is developed. The droplets show enhanced stability and phase conversion efficiency upon ultrasound exposure compared with existing formulations. Magnetic targeting, encapsulation, and release of an anticancer drug are demonstrated in vitro with a 40% improvement in cytotoxicity compared with free drug.

20 February 2017 in Advanced Healthcare Materials
Verified
Journal Article
Open access
PDF file
MCMarcus Caine
Marcus Caine
Dario CarugoDario Carugo
Dario Carugo
XZXunli Zhang
Xunli Zhang
MHMartyn Hill
Martyn Hill
MDMatthew R. Dreher
Matthew R. Dreher
ALAndrew L. Lewis
Andrew L. Lewis
Therapeutic embolotherapy is the deliberate occlusion of a blood vessel within the body, which can be for the prevention of internal bleeding, stemming of flow through an arteriovenous malformation, or occlusion of blood vessels feeding a tumor. This is achieved using a wide selection of embolic devices such as balloons, coils, gels, glues, and particles. Particulate embolization is often favored for blocking smaller vessels, particularly within hypervascularized tumors, as they are available in calibrated sizes and can be delivered distally via microcatheters for precise occlusion with associated locoregional drug delivery. Embolic performance has been traditionally evaluated using animal models, but with increasing interest in the 3R's (replacement, reduction, refinement), manufacturers, regulators, and clinicians have shown interest in the development of more sophisticated in vitro methods for evaluation and prediction of in vivo performance. Herein the current progress in developing bespoke techniques incorporating physical handling, fluid dynamics, occlusive behavior, and sustained drug elution kinetics within vascular systems is reviewed. While it is necessary to continue to validate the safety of such devices in vivo, great strides have been made in the development of bench tests that better predict the behavior of these products aligned with the principles of the 3R's.