Short-wavelength infrared (SWIR) and near-IR imaging (NIR) methods have been under development for almost 20 years for use in dentistry and several NIR clinical devices are now available commercially. Due to the high transparency of enamel at longer wavelengths, novel imaging configurations are feasible in which the tooth can be imaged from the occlusal surface after shining light at and below the gum line, which we call occlusal transillumination.1,2 Approximal lesions, the lesions located at the proximal contact points in between teeth, can be imaged via occlusal transillumination of the proximal contact points between teeth and by directing SWIR light below the crown while imaging the occlusal surface.2–4 The latter approach is capable of imaging occlusal lesions as well with high contrast.1,2,5–8 In 2010, it was demonstrated that approximal lesions that appeared on radiographs could be detected in vivo with SWIR imaging at 1310 nm with similar sensitivity2 and that occlusal transillumination could be employed clinically. This was the first step in demonstrating the clinical potential of NIR and SWIR imaging for approximal caries detection. In the most recent clinical study in 2016,9 SWIR transillumination and SWIR reflectance imaging probes were used to screen premolar teeth scheduled for extraction for caries lesions at wavelengths . The teeth were collected and sectioned into slices and examined with polarized light microscopy (PLM) and transverse microradiography that served as the gold standard. In addition, extra-oral radiographs were taken of teeth and the diagnostic performance of SWIR imaging was compared with radiography. The sensitivity of the combined SWIR imaging probes was significantly higher () than radiographs for both occlusal and approximal lesions in vivo. It was anticipated that SWIR methods would be more sensitive than radiographs for occlusal lesions since the radiographic sensitivity for occlusal lesions is extremely poor; however, the sensitivity was also much higher for approximal lesions than radiography, 0.53 versus 0.23. In addition, the sensitivity of each individual SWIR method was either individually equal to or higher than radiography.
The aim of this clinical study was to compare the diagnostic performance of dual short wavelength infrared (SWIR) occlusal transillumination and reflectance multispectral imaging with conventional visual assessment and radiography for caries detection on premolars scheduled for extraction for orthodontics reasons. Polarized light microscopy (PLM) and micro-computed tomography (microCT) performed after tooth extraction were used as gold standards. The custom-fabricated imaging probe was 3D-printed and the imaging system employed a SWIR camera and fiber-optic light sources emitting light at 1300 nm for occlusal transillumination and 1600 nm for reflectance measurements. Teeth (n = 135) on 40 test subjects were imaged in vivo using the SWIR imaging prototype in the study and teeth were extracted after imaging. Our study demonstrates for the first time that near-simultaneous real-time transillumination and reflectance video can be successfully acquired for caries detection. Both SWIR imaging modalities had markedly higher sensitivity for lesions on proximal and occlusal surfaces compared to conventional methods (visual and radiographic). Reflectance imaging at 1600 nm had higher sensitivity and specificity than transillumination at 1300 nm. The combined SWIR methods yielded higher specificity but the combined sensitivity was lower than for each individual method.
The aim of this study was to compare the diagnostic performance of dual short-wavelength infrared (SWIR) transillumination and reflectance multispectral imaging devices for imaging interproximal lesions with radiography using extracted teeth that had been imaged with micro-computed tomography (microCT). Thirty-six extracted teeth with 67 lesions on the proximal surfaces were imaged using a newly fabricated SWIR multispectral proximal transillumination and reflectance imaging device along with an existing SWIR multispectral occlusal transillumination and reflectance device. The ability of SWIR imaging and radiography to detect lesions and accurately assess lesion dimensions were compared using microCT as a standard. Occlusal and proximal transillumination and occlusal reflectance performed best for imaging interproximal lesions while proximal reflectance was not useful for imaging interproximal lesions from tooth buccal and lingual surfaces. There was high correlation of the lesion dimensions measured in occlusal and proximal transillumination images compared to microCT and moderate correlation in occlusal reflectance images. The correlation between the lesion depth measured in radiographs and the lesion depth measured with microCT was not significant. This study demonstrates that SWIR occlusal and proximal transillumination and SWIR occlusal reflectance images are useful for imaging interproximal lesions and they provide more accurate measurements of lesion severity.
The active surveillance of root caries lesions to monitor potential remineralization or decay progression is challenging for the clinician, due to unreliable diagnostic information. The conventional visual and tactile methods for assessing the lesion activity are not reliable, and the clinician is often unable to determine if the lesion is progressing or has been arrested. An important marker of an arrested lesion is a highly mineralized transparent surface zone (TSL) that forms when the mineral is deposited in the outer layer of the lesion. The purpose of this study was to determine if cross-polarization optical coherence tomography (CP-OCT) could be used to detect changes in the lesion severity and activity during active monitoring. In total, 18 subjects with 22 suspected active root caries lesions were evaluated using CP-OCT at the baseline, 3 months, and 6 months. All subjects were instructed to use a high fluoride dentifrice at the baseline. The results showed that CP-OCT was able to discriminate the active from the arrested lesions by identifying the presence of a TSL on arrested lesions. The results also indicated that the mean TSL thickness increased significantly (p < 0.05) for the nine lesion areas. In addition, CP-OCT was able to show the progression of demineralization, erosion, and changes in gingival contours in scanned areas. CP-OCT was valuable for monitoring the activity and severity of root caries lesions in vivo. CP-OCT can be used to assess the activity of root caries lesions at a single time point by detecting the presence of a TSL at the lesion surface indicative of the lesion arrest.
Stains produced by bacteria or those found in blood and food byproducts accumulate in highly porous caries lesions. They can interfere with accurate diagnosis and the selective removal of carious tissue during cavity preparations. Short-wavelength infrared (SWIR) imaging studies have shown that stain molecules do not absorb light beyond 1200 nm. The objective of this study was to image affected and infected dentin atSWIR wavelengths. Sections of 3 mm thickness were cut from the extracted teeth with deep dentinal lesions. The sound (normal), affected (stained), and infected (demineralized) dentin on each section were examined with reflected light at wavelengths from 400 to 1700 nm, red and green fluorescence, and with optical coherence tomography (OCT). Microcomputed tomography (microCT) was used to measure the mineral density at each location investigated. Significant (p < 0.05) differences were observed in the reflected light intensity at 400–850 nm and for fluorescence between the sound, affected, and infected dentin. SWIR imaging did not show significant reductions in reflectivity for the affected and infected dentin. SWIR images may be valuable for monitoring the lateral spread of dentinal lesions on the occlusal surfaces of teeth.
We have developed a clinical probe capable of acquiring simultaneous short wavelength infrared (SWIR) cross-polarized reflectance and occlusal transillumination images of lesions on tooth proximal and occlusal surfaces. We hypothesize that the dual SWIR reflectance and transillumination probe will improve the diagnostic accuracy of the device by reducing false positives since it is unlikely that confounding structural features or specular reflection are going to be present in both reflectance and transillumination images. In addition, the dual probe will provide complementary diagnostic information about lesion severity to help discriminate early superficial lesions on tooth surfaces from deeply penetrating lesions. The dual probe was 3D printed and equipped with a compact InGaAs camera and broadband superluminescent diode light sources that emit broadband light at 1300 nm for occlusal transillumination and 1600 nm light for cross-polarization reflectance measurements. The first clinical images acquired using this novel probe are presented.