Epifanio Cruz-Zaragoza

Dr. Epifanio Cruz-Zaragoza


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
GRG. Cedillo Del Rosario
G. Cedillo Del Rosario
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
MHM. García Hipólito
M. García Hipólito
JMJ. Marcazzó
J. Marcazzó
JAJ.M. Hernández A.
J.M. Hernández A.
HSH. Murrieta S
H. Murrieta S

25 January 2011 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
SGS. Guzmán
S. Guzmán
BGB. Ruiz Gurrola
B. Ruiz Gurrola
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
ATA. Tufiño
A. Tufiño
CFC. Furetta
C. Furetta
FBFrancisco Brown
Francisco Brown
The inorganic mineral fraction extracted from black pepper (Piper nigrum L.) has been analysed using a thermoluminescence (TL) method, investigating the glow curve structure, including an evaluation of the kinetic parameters. Different grain sizes, i.e. 10, 74, and 149 μm, were selected from commercial black pepper. The X-ray diffraction of the inorganic fraction shows that quartz is the main mineral present in it. The samples were exposed to 1–25 kGy doses by gamma rays of 60Co in order to analyse the thermally stimulated luminescence response as a function of the delivered dose. The glow curves show a complex structure for different grain sizes of the pepper mineral samples. The fading of the TL signal at room temperature was obtained after irradiation, and it was observed that the maximum peaks of the glow curves shift towards higher values of the temperature when the elapsed time from irradiation increases. It seems that the fading characteristic may be related to a continuous trap distribution responsible for the complex structure of the glow curve. Similar glow curves structure behaviour was found under ultraviolet irradiation of the samples. The activation energy and the frequency factor were determined from the glow curves of different grain sizes using a deconvolution programme because of the evident complexity of the structure.

29 October 2010 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
AOA. Ortiz
A. Ortiz
CFC. Furetta
C. Furetta
CJC. Flores J
C. Flores J
JAJ. Hernández A
J. Hernández A
HSH. Murrieta S
H. Murrieta S

1 June 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
JRJesús Román-López
Jesús Román-López
DCD. Ramos Córdoba
D. Ramos Córdoba
CFC. Furetta
C. Furetta
MSM. Santiago
M. Santiago
JMJ. Marcazzó
J. Marcazzó

1 November 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
LPL. Pérez-Cruz
L. Pérez-Cruz
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
DDD. Díaz
D. Díaz
JAJ.M. Hernández Alcántara
J.M. Hernández Alcántara
EGE. Camarillo García
E. Camarillo García
HSH. Murrieta Sánchez
H. Murrieta Sánchez

1 August 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
AOA. Ortiz-Morales
A. Ortiz-Morales
JOJ. Ortiz-Lopez
J. Ortiz-Lopez
ECEpifanio Cruz-Zaragoza
Epifanio Cruz-Zaragoza
RGR. Gómez-Aguilar
R. Gómez-Aguilar