Aims: Ventricular tachycardia (VT) substrate-based ablation has become a standard procedure. Electroanatomical mapping (EAM) detects scar tissue heterogeneity and define conduction channels (CCs) that are the ablation target. Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is able to depict CCs and increase ablation success. Most patients undergoing VT ablation have an implantable cardioverter-defibrillator (ICD) that can cause image artefacts in LGE-CMR. Recently wideband (WB) LGE-CMR sequence has demonstrated to decrease these artefacts. The aim of this study is to analyse accuracy of WB-LGE-CMR in identifying the CC entrances. Methods and results: Thirteen consecutive ICD-patients who underwent VT ablation after WB-LGE-CMR were included. Number and location of CC entrances in three-dimensional EAM and in WB-LGE-CMR reconstruction were compared. Concordance was compared with a historical cohort matched by cardiomyopathy, scar location, and age (26 patients) with LGE-CMR prior to ICD and VT ablation. In WB-CMR group, 101 and 93 CC entrances were identified in EAM and WB-LGE-CMR, respectively. In historical cohort, 179 CC entrances were identified in both EAM and LGE-CMR. The EAM/CMR concordance was 85.1% and 92.2% in the WB and historical group, respectively (P = 0.66). There were no differences in false-positive rate (CC entrances detected in CMR and absent in EAM: 7.5% vs 7.8% in WB vs. conventional CMR, P = 0.92) nor in false-negative rate (CC entrances present in EAM not detected in CMR: 14.9% vs.7.8% in WB vs. conventional CMR, P = 0.23). Epicardial CCs was predictor of poor CMR/EAM concordance (OR 2.15, P = 0.031). Conclusion: Use of WB-LGE-CMR sequence in ICD-patients allows adequate VT substrate characterization to guide VT ablation with similar accuracy than conventional LGE-CMR in patients without an ICD.
Scar characteristics analyzed by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related with ventricular arrhythmias. Current guidelines are based only on the left ventricular ejection fraction to recommend an implantable cardioverter-defibrillator (ICD) in primary prevention. Our study aims to analyze the role of imaging to stratify arrhythmogenic risk in patients with ICD for primary prevention. From 2006 to 2017, we included 200 patients with LGE-CMR before ICD implantation for primary prevention. The scar, border zone, core, and conducting channels (CCs) were automatically measured by a dedicated software. The mean age was 60.9 ± 10.9 years; 81.5% (163) were men; 52% (104) had ischemic cardiomyopathy. The mean left ventricular ejection fraction was 29% ± 10.1%. After a follow-up of 4.6 ± 2 years, 46 patients (22%) reached the primary end point (appropriate ICD therapy). Scar mass (36.2 ± 19 g vs 21.7 ± 10 g; P < .001), border zone mass (26.4 ± 12.5 g vs 16.0 ± 9.5 g; P < .001), core mass (9.9 ± 8.6 g vs 5.5 ± 5.7 g; P < .001), and CC mass (3.0 ± 2.6 g vs 1.6 ± 2.3 g; P < .001) were associated with appropriate therapies. Scar mass > 10 g (25.31% vs 5.26%; hazard ratio 4.74; P = .034) and the presence of CCs (34.75% vs 8.93%; hazard ratio 4.07; P = .003) were also strongly associated with the primary end point. However, patients without channels and with scar mass < 10 g had a very low rate of appropriate therapies (2.8%). Scar characteristics analyzed by LGE-CMR are strong predictors of appropriate therapies in patients with ICD in primary prevention. The absence of channels and scar mass < 10 g can identify patients at a very low risk of ventricular arrhythmias in this population.
18 October 2022 in Journal of the American Heart Association
Background: Left atrial structural remodeling contributes to the arrhythmogenic substrate of atrial fibrillation (AF), but the role of the right atrium (RA) remains unknown. Our aims were to comprehensively characterize right atrial structural remodeling in AF and identify right atrial parameters predicting recurrences after ablation. Methods and Results: A 3.0 T late gadolinium enhanced–cardiac magnetic resonance was obtained in 109 individuals (9 healthy volunteers, 100 patients with AF undergoing ablation). Right and left atrial volume, surface, and sphericity were quantified. Right atrial global and regional fibrosis burden was assessed with validated thresholds. Patients with AF were systematically followed after ablation for recurrences. Progressive right atrial dilation and an increase in sphericity were observed from healthy volunteers to patients with paroxysmal and persistent AF; fibrosis was similar among the groups. The correlation between parameters recapitulating right atrial remodeling was mild. Subsequently, remodeling in both atria was compared. The RA was larger than the left atrium (LA) in all groups. Fibrosis burden was higher in the LA than in the RA of patients with AF, whereas sphericity was higher in the LA of patients with persistent AF only. Fibrosis, volume, and surface of the RA and LA, but not sphericity, were strongly correlated. Tricuspid regurgitation predicted right atrial volume and shape, whereas diabetes was associated with right atrial fibrosis burden; sex and persistent AF also predicted right atrial volume. Fibrosis in the RA was mostly located in the inferior vena cava–RA junction. Only right atrial sphericity is significantly associated with AF recurrences after ablation (hazard ratio, 1.12 [95% CI, 1.01–1.25]). Conclusions: AF progression associates with right atrial remodeling in parallel with the LA. Right atrial sphericity yields prognostic significance after ablation.
Substrate-based ventricular tachycardia (VT) ablation is a first-line treatment in patients with structural cardiac disease and sustained VT refractory to medical therapy. Despite technological improvements and increased knowledge of VT substrate, recurrence still is frequent. Published data are lacking on the possible reduction in VT burden after ablation despite recurrence. The purpose of this study was to assess VT burden reduction during long-term follow-up after substrate ablation and identify predictors of VT recurrence. We analyzed 234 consecutive VT ablation procedures in 207 patients (age 63 ± 14.9 years; 92% male; ischemic heart disease in 65%) who underwent substrate ablation in a single center from 2013 to 2018. After follow-up of 3.14 ± 1.8 years, the VT recurrence rate was 41.4%. Overall, a 99.6% reduction in VT burden (median VT episodes per year: preprocedural 3.546 [1.347-13.951] vs postprocedural 0.001 [0-0.689]; P = .001) and a 96.3% decrease in implantable cardioverter-defibrillator (ICD) shocks (preprocedural 1.145 [0.118-4.467] vs postprocedural 0.042 [0-0.111] per year; P = .017) were observed. In the subgroup of patients who experienced VT recurrences, VT burden decreased by 69.2% (median VT episodes per year: preprocedural 2.876 [1.105-8.801] vs postprocedural 0.882 [0.505-2.283]; P <.001). Multivariable analysis showed persistence of late potentials (67% vs 19%; hazard ratio 3.18 [2.18-6.65]; P <.001) and lower left ventricular ejection fraction (EF) (30 [25-40] vs 39 [30-50]; P = .022) as predictors of VT recurrence. Despite a high recurrence rate during long-term follow-up, substrate-based VT ablation is related to a large reduction in VT burden and a decrease in ICD therapies. Lower EF and persistence of late potentials are predictors of recurrence.
Aims: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics.Methods and results: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01–1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18–2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04–1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07–1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15–2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity.Conclusion: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.
Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.