Prasannavenkadesan Varatharajan

Dr. Prasannavenkadesan Varatharajan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2024 in RSC Applied Polymers
Verified
Journal Article
Open access
PDF file
RSRam Prasanth S.
Ram Prasanth S.
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan
VKVimal Katiyar
Vimal Katiyar
ASAchalkumar Ammathnadu Sudhakar
Achalkumar Ammathnadu Sudhakar
Polymer electrolytes have been an effective alternative to conventional liquid electrolytes in battery applications due to their advantages, which demand an increased attention to improve them further.

21 June 2021 in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan
PPPonnusamy Pandithevan
Ponnusamy Pandithevan
Compression plates are widely used in orthopaedic surgeries for internal fixation of fractured femurs. To fix the plate and thus to provide compression to a fracture, the self-tapping bone screws are tightened through predrilled pilot holes of smaller diameter. Preliminary investigation showed that the holes drilled with the inappropriate cutting parameters cause mechanical and thermal damages to the local host bone, which further lead to loosening of internal fixations. In this paper, the mechanistic models to predict the thrust forces and torques during bone drilling were developed, using a 3.20 mm diameter drill bit. As a procedure, the cutting action was investigated at three different regions of the drill point, namely cutting lips, secondary cutting edges and indentation zone. The models employed the analytical approach to account for the drill-bit geometry and cutting parameters, and an empirical approach to account for the material and friction properties. To complete the procedure, calibration experiments were conducted on bovine cortical femurs with two different spindle speeds (1000 and 3000 r/min) and feeds (0.03 and 0.06 mm/rev), and then the specific normal and friction coefficients were determined. The developed mechanistic models were validated with different ranges of parameters (500–3500 r/min speeds, and 0.02–0.07 mm/rev feeds) those commonly involved in manual and robot-assisted surgery. The validation study revealed that the thrust forces predicted using the mechanistic models showed a maximum error of only 5.80%. However, the torques predicted from the mechanistic model found with more error than the thrust forces. The predominant reasons for this under-prediction might because of the extrapolation used to determine the specific cutting pressures, slip-line field applied to the indentation zone instead of compressive fracture, and chip clogging involved during the bone drilling as demonstrated in earlier studies. Despite the deviations, the developed mechanistic models satisfactorily follow the trends of the thrust forces and torques experienced during bone drilling. The outcomes can be used to practice the bone drilling procedure and monitor the effect of process parameters on thrust forces and torques in the in-silico environment before performing actual surgery.

2 May 2022 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan
PPPonnusamy Pandithevan
Ponnusamy Pandithevan
In orthopaedic surgeries, drilling through bone is most widely used to fix the plates and implants. The uncontrolled large thrust forces generated during bone drilling cause micro-crack, and fragmentation around the local host bone which further loosen the implant and fixation. Owing to the experimental limitation and the risk of infection in handling the bone specimens, conducting experiments with all possible combinations of parameter values and selecting the suitable combination is largely limited. So in this paper, finite element analysis coupled with the constitutive models was used to early predict the thrust forces generated in the surgical bone drilling process. The constitutive models developed in the earlier study, namely, Johnson–Cook, Cowper–Symonds, and Johnson–Cook combined with Cowper–Symonds that consider the strain rate dependence of plastic curve were used for the simulations. Results revealed that the trends of the thrust force values predicted from the constitutive models matched well with the experiments. However, the study showed that the Johnson–Cook model combined with the Cowper–Symonds model predicted the thrust forces with a maximum error of only 9.51% followed by the Johnson–Cook model and Cowper–Symonds model with 15.83% and 21.89%, respectively. The outcomes of the study can be used to predict the thrust forces generated in the bone drilling process, and thus, suitable parameters values can be selected to avoid the mechanical damages around the bone drilling site. The outcomes can also be used to plan and rehearse the in-silico bone drilling trials with any combinations of parameter values before performing the actual surgery.

15 July 2023 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
PDF file
PPPonnusamy Pandithevan
Ponnusamy Pandithevan
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan

23 January 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan
CSChockalingam Singaravelu
Chockalingam Singaravelu

5 February 2026 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Closed access
PDF file
GSGeetha Sundaram
Geetha Sundaram
PVPrasannavenkadesan Varatharajan
Prasannavenkadesan Varatharajan
RKRamanathan Kalimuthu
Ramanathan Kalimuthu
SSSelvaraj Sathiyaseelan
Selvaraj Sathiyaseelan