Today, electric drive systems based on frequency converters with active front-end rectifiers (FC-AFEs) are widespread across industries. In the course of the upgrade of production facilities, such systems replace the conventional converters with thyristor- and diode-based rectifiers. FC-AFEs have the following advantages: the capacity to regenerate the power to the grid and the capacity to operate at the set power factor. The manufacturers of FC-AFEs also claim that their products have the best electromagnetic compatibility (EMC) with the power grid. The best EMC shall be achieved via a multilevel FC-AFE topology and specialized pulse-width modulation (PWM) algorithms for AFE rectifiers. However, the experience of operating mid-voltage high-power electric drives with an FC-AFE in 6–35 kV factory distribution grids with non-linear frequency response due to resonant phenomena refutes the claims of the FC-AFE manufacturers. Resonant phenomena in 6–35 kV grids are caused by the interaction of the inductance of grid components (transformers, reactors) and the capacitance of output cable lines. If the resonance frequency at a sufficient amplitude corresponds to the harmonic frequency of the current consumed by the FC-AFE, the distribution grid will feature high-frequency voltage distortions. This may lead to failures in voltage quality-sensitive electrical consumers. This problem recurred at various metallurgical companies. The purpose of this research is to make a comprehensive overview of the EMC problems during the operation of FC-AFEs at active production facilities, as well as the analysis of the technical solutions aimed at the improvement of the EMC of high-power FC-AFEs with the power grid.
This paper presents the method of ensuring electromagnetic compatibility of frequency converters with active rectifiers ACS6000 as a part of main electric drives of four-stand mill with 10 kV distribution network of in-plant power supply system at JSC “Severstal” Cherepovets Steel Mill. The essence of the used method was in application of improved algorithms of PWM for active rectifiers of frequency converters ACS6000 ensuring harmonic composition alteration of currents consumed by ARs with exclusion of harmonics falling into the zone of resonances in the frequency response of the network relative to sections of 10 kV GPP-2. Theoretical studies were conducted on a complex mathematical model of the main electric drives of the mill and the internal 10 kV distribution network implemented in the mathematical package Matlab-Simulink. The analysis of research results showed the effectiveness of the proposed method in terms of reducing the total harmonic distortion factor on the sections of the main step-down substation of the plant, which are intrafactory points of common connection.
This paper studies power factors in the internal power supply system of metallurgical plant frequency converters with active rectifiers. A simulation model of the three-level twelve-pulse active rectifiers has been developed and implemented in the Matlab/Simulink environment for investigation purposes. Four different pulse-width modulation algorithms used at the operated active rectifiers and the DC-link voltage control system have been realized. In addition, the harmonic composition of consumed current and network voltage at the active rectifier connection point have been analyzed. The compliance of the harmonics' level with the power quality standard (GOST 32144-2013) has been verified. The conclusions about the efficiency of existing pulse-width modulation algorithms have been made.
Active rectifiers are widely used on industrial sites today. These units are part of high power regulated alternating current drives. Their use is due to a number of advantages over classic diode rectifiers, such as the ability to recover braking energy into the supply network and, according to the manufacturers, better electromagnetic compatibility. However, experience in operating these devices shows that due to the use of pulse-width modulation in active rectifiers, there is a high severe distortion probability of supply mains voltage by high order harmonics, with numbers higher than 40-50. The essence of this phenomenon is the occurrence of a voltage drop in the high impedance parts of the network frequency response when even a small high-frequency current is flowing. The presence of high impedance sections in the frequency response is due to the parallel resonance between the inductance of the network transformer and the equivalent capacitance of the cables from the substation. Modern power quality standards applied in different countries do not take into account harmonics above 40-50 which makes it very difficult to assess the impact of high-power drives with active rectifiers on power quality in the supply network by conventional, certified power quality analysers. Therefore, it is an urgent task to develop a specialised methodology to assess the impact degree of a particular active rectifier on the network.
Medium voltage distribution networks of 6 - 35 kV are used in in-plant power supply systems in steel mills. As a mutual influence result of the capacitances of long cable lines and the inductances of step-down transformers, resonance phenomena can occur in the medium frequency range. If the high-frequency harmonics generated by frequency converters with active rectifiers fall into the resonant range, this can lead to disturbances in the plant’s internal distribution network. Such phenomena can cause long downtime of technological equipment and product defects. This entails significant economic losses, especially in the production of high value-added products. This paper reflects the experimental research results of voltage quality in 34.5 kV distribution networks of metallurgical plant “MMK Metalurji”. Measures for electromagnetic compatibility improvement of frequency converters with active rectifiers of electric drives in hot strip mill 1750 with supply mains are proposed.
The paper investigates the dynamic operation modes of frequency converter active rectifiers with the previously proposed improved control system. This control system allows the use of IGCT thyristors switching angle tables with different switching frequencies depending on the operating mode of the frequency converter. The tables were changed when the equal control signals to the power switches of the active rectifier were generated using the current and the new tables. The research has been performed on the previously developed simulation model in the Matlab-Simulink software package. The analysis of the research results has shown the minimum disturbing effects on the regulated parameters of the active rectifier when changing the tables.