Léo Antoine MOTTAY

Mr. Léo Antoine MOTTAY

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
PDPierre Decazes
Pierre Decazes
SASAMY AMMARI
SAMY AMMARI
APAntoine de Prévia
Antoine de Prévia
LMLéo Antoine MOTTAY
Léo Antoine MOTTAY
LLLittisha LAWRANCE
Littisha LAWRANCE
NLNathalie Lassau
Nathalie Lassau
Background: Body composition could help to better define the prognosis of cancers treated with anti-angiogenics. The aim of this study is to evaluate the prognostic value of 3D and 2D anthropometric parameters in patients given anti-angiogenic treatments. Methods: 526 patients with different types of cancers were retrospectively included. The software Anthropometer3DNet was used to measure automatically fat body mass (FBM3D), muscle body mass (MBM3D), visceral fat mass (VFM3D) and subcutaneous fat mass (SFM3D) in 3D computed tomography. For comparison, equivalent two-dimensional measurements at the L3 level were also measured. The area under the curve (AUC) of the receiver operator characteristics (ROC) was used to determine the parameters’ predictive power and optimal cut-offs. A univariate analysis was performed using Kaplan–Meier on the overall survival (OS). Results: In ROC analysis, all 3D parameters appeared statistically significant: VFM3D (AUC = 0.554, p = 0.02, cutoff = 0.72 kg/m2), SFM3D (AUC = 0.544, p = 0.047, cutoff = 3.05 kg/m2), FBM3D (AUC = 0.550, p = 0.03, cutoff = 4.32 kg/m2) and MBM3D (AUC = 0.565, p = 0.007, cutoff = 5.47 kg/m2), but only one 2D parameter (visceral fat area VFA2D AUC = 0.548, p = 0.034). In log-rank tests, low VFM3D (p = 0.014), low SFM3D (p < 0.0001), low FBM3D (p = 0.00019) and low VFA2D (p = 0.0063) were found as a significant risk factor. Conclusion: automatic and 3D body composition on pre-therapeutic CT is feasible and can improve prognostication in patients treated with anti-angiogenic drugs. Moreover, the 3D measurements appear to be more effective than their 2D counterparts.

15 October 2026 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
LMLéo Antoine MOTTAY
Léo Antoine MOTTAY
PDPierre Decazes
Pierre Decazes
SHSébastien Hapdey
Sébastien Hapdey
Ruan SuRuan Su
Ruan Su

13 October 2026
Verified
Thesis
Closed access
LMLéo Antoine MOTTAY
Léo Antoine MOTTAY
Imagerie TEP dynamique à double traceur pour l'exploration du cancer de la prostate: La tomographie par émission de positons (TEP) permet de visualiser les processus biologiques grâce à des radiotraceurs spécifiques. Chez les patients atteints d'un cancer de la prostate résistant à la castration, les radiotraceurs \textsuperscript{18}F-FDG et \textsuperscript{68}Ga-PSMA apportent des informations complémentaires sur le métabolisme tumoral et l'expression du PSMA. Leur acquisition simultanée permettrait d'obtenir ces informations en un seul examen, mais leurs signaux ne peuvent être directement distingués par les systèmes TEP conventionnels.Cette thèse propose une approche hybride combinant modélisation physiologique et apprentissage profond pour séparer les signaux de deux radiotraceurs en TEP dynamique. Les travaux reposent sur une cohorte clinique prospective, un environnement de simulation 4D réaliste construit à partir d'examens TEP statiques et plusieurs architectures neuronales, aboutissant à un modèle hybride intégrant explicitement un modèle compartimental irréversible à deux tissus (2TCM).Les résultats montrent que l'intégration de connaissances physiologiques améliore systématiquement la précision, la robustesse et la capacité de généralisation de la séparation bi-traceur, en particulier dans les organes présentant des cinétiques complexes. Cette thèse fournit ainsi un cadre méthodologique complet pour l'étude de la TEP dynamique bi-traceur et met en évidence le potentiel des approches hybrides pour le développement de méthodes quantitatives en imagerie TEP multi-traceur.