Sensor faults frequently occur in wastewater treatment plant (WWTP) operation, leading to incomplete monitoring or poor control of the plant. Reliable operation of the WWTP considerably depends on the aeration control system, which is essentially assisted by the dissolved oxygen (DO) sensor. Results on the detection of different DO sensor faults, such as bias, drift, wrong gain, loss of accuracy, fixed value, or complete failure, were investigated based on Principal Components Analysis (PCA). The PCA was considered together with two statistical approaches, i.e., the Hotelling’s T2 and the Squared Prediction Error (SPE). Data used in the study were generated using the previously calibrated first-principle Activated Sludge Model no.1 for the Anaerobic-Anoxic-Oxic (A2O) reactors configuration. The equation-based model was complemented with control loops for DO concentration control in the aerobic reactor and nitrates concentration control in the anoxic reactor. The PCA data-driven model was successfully used for the detection of the six investigated DO sensor faults. The statistical detection approaches were compared in terms of promptness, effectiveness, and accuracy. The obtained results revealed the way faults originating from DO sensor malfunction can be detected and the efficiency of the detection approaches for the automatically controlled WWTP.
Sensor failures are common events in wastewater treatment plant (WWTP) operations, resulting in ineffective monitoring and inappropriate plant management. Efficient aeration control is typically achieved by the dissolved oxygen (DO) control, and its associated sensor becomes critical to the whole WWTP’s reliable and economical operation. This study presents the Fisher discriminant analysis (FDA) used for fault diagnosis of the DO sensor of a currently operating municipal WWTP. Identification of the bias, drift, wrong gain, loss of accuracy, fixed value, complete failure minimum and maximum types of DO sensor fault was investigated. The FDA-proposed methodology proved efficiency and promptitude in obtaining the diagnosis decision. The consolidated fault identification showed an accuracy of 87.5% correct identification of the seven faulty and normal considered classes. Depending on the fault type, the results of the diagnosing time varied from 2.5 h to 16.5 h during the very first day of the fault appearance and were only based on observation data not included in the training data set. The latter aspect reveals the potential of the methodology to learn from incomplete data describing the faults. The rank of the fault type detection promptitude was: bias, fixed value, complete failure minimum, complete failure maximum, drift, wrong gain and loss of accuracy. Greenhouse gases (GHGs) such as nitrous oxide (N2O) and carbon dioxide (CO2) emitted during wastewater treatment, electrical energy quantity in association with costs spent in the WWTP water line and clean water effluent quality were ranked and assessed for the normal operation and for each of the DO sensor faulty regimes. Both for CO2 and N2O, the on-site emissions showed the most significant GHG contribution, accounting for about three-quarters of the total emissions. The complete failure maximum, fixed value and loss of accuracy were the DO sensor faults with the highest detrimental impact on GHG-released emissions. The environmental and economic study reveals the incentives of the proposed DO sensor faults identification for the WWTP efficient and environmentally friendly operation.
1 June 2021 in Journal of Environmental Management
One of the leading challenges in Water Resource Recovery Facility monitoring and control is the poor data quality and sensor consistency due to the tough and complex circumstances of the process operation. This paper presents a new principal component analysis fault detection approach for the nitrate and nitrite concentration sensor based on Water Resource Recovery Facility measurements, together with the Fisher Discriminant Analysis identification of fault types. Five malfunction cases were considered: constant additive error, ramp changing error in time, incorrect amplification error, random additive error, and unchanging sensor value error. The faults’ implementation, fault detection, and identification methods are presented and evaluated in terms of accuracy and promptitude. The models are originating from a municipal plant. The amount of required electrical energy and greenhouse gas released during the Water Resource Recovery Facility operation were assessed for the cases of nitrates and nitrites NO sensor normal and malfunctioning regimes. The environmental and economic evaluations show the benefits of detecting and identifying nitrates and nitrites NO sensor defects aimed at providing efficient and environmentally friendly operation of the Water Resource Recovery Facility. The fault-affected operation cases showed increased values, up to 10% for the total energy demand and 4% for the total greenhouse gas emissions, when they are compared to the normal operation case.