Lu Wang

Dr. Lu Wang

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2007 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
SAS. S. An
S. S. An
TBT. R. Bai
T. R. Bai
JBJ. H. T. Bates
J. H. T. Bates
JBJ. L. Black
J. L. Black
RBR. H. Brown
R. H. Brown
LWLu Wang
Lu Wang
Excessive airway obstruction is the cause of symptoms and abnormal lung function in asthma.As airway smooth muscle (ASM) is the effecter controlling airway calibre, it is suspected that dysfunction of ASM contributes to the pathophysiology of asthma. However, the precise role of ASM in the series of events leading to asthmatic symptoms is not clear. It is not certain whether, in asthma, there is a change in the intrinsic properties of ASM, a change in the structure and mechanical properties of the noncontractile components of the airway wall, or a change in the interdependence of the airway wall with the surrounding lung parenchyma. All these potential changes could result from acute or chronic airway inflammation and associated tissue repair and remodelling.Anti-inflammatory therapy, however, does not “cure” asthma, and airway hyperresponsiveness can persist in asthmatics, even in the absence of airway inflammation. This is perhaps because the therapy does not directly address a fundamental abnormality of asthma, that of exaggerated airway narrowing due to excessive shortening of ASM.In the present study, a central role for airway smooth muscle in the pathogenesis of airway hyperresponsiveness in asthma is explored.

1 June 2000 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
LWLu Wang
Lu Wang
PPPeter D. Paré
Peter D. Paré
CSChun Y. Seow
Chun Y. Seow
It has been shown that deep inspiration (DI) taken before application of bronchoconstricting stimuli causes a reduction in the subsequent bronchoconstriction; a fast DI has a greater inhibitory effect than a slow DI. We hypothesize that periodic length changes imposed on a relaxed airway smooth muscle (ASM) would attenuate subsequent bronchoconstriction by disrupting the organization of the contractile apparatus, and this could be an important mechanism for the observed bronchoprotective effect of DI and tidal breathing. Length oscillations of different amplitude, frequency, and duration were applied to a relaxed muscle. The effects of such perturbations on force development were then assessed. Results show that oscillations reduce the subsequent force generation and that the magnitude of force reduction is proportional to amplitude and duration of the length oscillation. After the oscillation, isometric force recovered to the preoscillation level in a series of isometric contractions, and the rate of recovery was facilitated by frequent stimulation. The in vitro behavior of ASM found in this study could account for the observed temporary reduction in bronchoconstriction subsequent to a DI.

1 February 2001 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
LWLu Wang
Lu Wang
PPPeter D. Paré
Peter D. Paré
CSChun Y. Seow
Chun Y. Seow
The ability of rabbit trachealis to undergo plastic adaptation to chronic shortening or lengthening was assessed by setting the muscle preparations at three lengths for 24 h in relaxed state: a reference length in which applied force was ∼1–2% of maximal active force (Po) and lengths considerably shorter and longer than the reference. Passive and active length-tension ( L-T) curves for the preparations were then obtained by electrical field stimulation at progressively increasing muscle length. Classically shaped L-T curves were obtained with a distinct optimal length ( Lo) at which Podeveloped; however, both the active and passive L-T curves were shifted, whereas Poremained unchanged. Lowas 72% and 148% that of the reference preparations for the passively shortened and lengthened muscles, respectively. The results suggest that chronic narrowing of the airways could induce a shift in the L-T relationship of smooth muscle, resulting in a maintained potential for maximal force production.

1 May 2001 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
KKKuo-Hsing Kuo
Kuo-Hsing Kuo
LWLu Wang
Lu Wang
PPPeter D. Paré
Peter D. Paré
LFLincoln E. Ford
Lincoln E. Ford
CSChun Y. Seow
Chun Y. Seow
Airway smooth muscle adapts to different lengths with functional changes that suggest plastic alterations in the filament lattice. To look for structural changes that might be associated with this plasticity, we studied the relationship between isometric force generation and myosin thick filament density in cell cross sections, measured by electron microscope, after length oscillations applied to the relaxed porcine trachealis muscle. Muscles were stimulated regularly for 12 s every 5 min. Between two stimulations, the muscles were submitted to repeated passive ±30% length changes. This caused tetanic force and thick-filament density to fall by 21 and 27%, respectively. However, in subsequent tetani, both force and filament density recovered to preoscillation levels. These findings indicate that thick filaments in airway smooth muscle are labile, depolymerization of the myosin filaments can be induced by mechanical strain, and repolymerization of the thick filaments underlies force recovery after the oscillation. This thick-filament lability would greatly facilitate plastic changes of lattice length and explain why airway smooth muscle is able to function over a large length range.

1 December 2004 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
TBTony R. Bai
Tony R. Bai
JBJason H. T. Bates
Jason H. T. Bates
VBVito Brusasco
Vito Brusasco
BCBlanca Camoretti-Mercado
Blanca Camoretti-Mercado
PCPasquale Chitano
Pasquale Chitano
LWLu Wang
Lu Wang
The observation that the length-force relationship in airway smooth muscle can be shifted along the length axis by accommodating the muscle at different lengths has stimulated great interest. In light of the recent understanding of the dynamic nature of length-force relationship, many of our concepts regarding smooth muscle mechanical properties, including the notion that the muscle possesses a unique optimal length that correlates to maximal force generation, are likely to be incorrect. To facilitate accurate and efficient communication among scientists interested in the function of airway smooth muscle, a revised and collectively accepted nomenclature describing the adaptive and dynamic nature of the length-force relationship will be invaluable. Setting aside the issue of underlying mechanism, the purpose of this article is to define terminology that will aid investigators in describing observed phenomena. In particular, we recommend that the term “optimal length” (or any other term implying a unique length that correlates with maximal force generation) for airway smooth muscle be avoided. Instead, the in situ length or an arbitrary but clearly defined reference length should be used. We propose the usage of “length adaptation” to describe the phenomenon whereby the length-force curve of a muscle shifts along the length axis due to accommodation of the muscle at different lengths. We also discuss frequently used terms that do not have commonly accepted definitions that should be used cautiously.

1 August 2003 in American Journal of Physiology-Cell Physiology
Verified
Journal Article
Open access
PDF file
KKKuo-Hsing Kuo
Kuo-Hsing Kuo
AHAna M. Herrera
Ana M. Herrera
LWLu Wang
Lu Wang
PPPeter D. Paré
Peter D. Paré
LFLincoln E. Ford
Lincoln E. Ford
CSChun Y. Seow
Chun Y. Seow
Airway smooth muscle is able to adapt and maintain a nearly constant maximal force generation over a large length range. This implies that a fixed filament lattice such as that found in striated muscle may not exist in this tissue and that plastic remodeling of its contractile and cytoskeletal filaments may be involved in the process of length adaptation that optimizes contractile filament overlap. Here, we show that isometric force produced by airway smooth muscle is independent of muscle length over a twofold length change; cell cross-sectional area was inversely proportional to cell length, implying that the cell volume was conserved at different lengths; shortening velocity and myosin filament density varied similarly to length change: increased by 69.4% ± 5.7 (SE) and 76.0% ± 9.8, respectively, for a 100% increase in cell length. Muscle power output, ATPase rate, and myosin filament density also have the same dependence on muscle cell length: increased by 35.4% ± 6.7, 34.6% ± 3.4, and 35.6% ± 10.6, respectively, for a 50% increase in cell length. The data can be explained by a model in which additional contractile units containing myosin filaments are formed and placed in series with existing contractile units when the muscle is adapted at a longer length.