Li Tong

Dr. Li Tong


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2023 in Buildings
Verified
Journal Article
Open access
PDF file
LTLi Tong
Li Tong
NLNian Liu
Nian Liu
SHSongtao Hu
Songtao Hu
MLMingli Lu
Mingli Lu
YZYuxi Zheng
Yuxi Zheng
XMXiaohui Ma
Xiaohui Ma
The quality of the indoor light environment in buildings directly influences the emotional state, health condition, and work efficiency of people. The application of EEG to indoor light environments is beneficial to further reveal the neural mechanisms of light comfort. In this study, the absolute power of spontaneous EEG was calculated as an objective physiological index, and its trend with the illuminance level of the task area was analyzed. Then, the absolute power of the band, which has the strongest correlation with subjective evaluation and task performance, was selected as the characteristic value. The subjective and objective parameters were validated to explore the preferred illuminance choices for subjects’ comfort and efficiency during the rest stage and the task stage, respectively. The results showed that the power of the δ band and β band at partial channels in the parietal region had statistically significant differences under five illuminance levels in the resting state. The total logarithmic power of EEG and the logarithmic power of the δ band at the Cz channel were negatively correlated with the subjective evaluation. The total logarithmic power of EEG was relatively low when the subjective evaluation was comfortable. There was no statistical difference in the total EEG logarithmic power among the five illuminance levels in the task state, but the subjects had the highest performance indicator and the best cognitive task performance at 500 lux and 750 lux conditions. This research may provide a design reference for the selection of task area illuminance levels for staff during high-intensity mental work and rest.

16 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LTLi Tong
Li Tong
MZMingzhi Zhang
Mingzhi Zhang
SHSongtao Hu
Songtao Hu
YJYongming Ji
Yongming Ji
The deteriorating thermal environment of tunnels and the increase in energy consumption of environmental control systems has become highlights in the subway field. In existing research related to analysis of subway tunnel thermal environments and thermal accumulation; there is no predictive law that accounts for thermal accumulation or the long-term change in subway tunnel thermal environments. In this study, a combination of simulations and experiments is used. First, the long-term evolution of tunnel thermal environments with and without thermal interference are predicted and analyzed. Then, the changes in the tunnel thermal environment after the use of capillary heat exchangers are explored. The research results indicate that the model of the system has high accuracy and reliability. When there is a capillary heat exchanger installed in the subway tunnel, the anti-seasonal heat storage characteristics of the system result in the tunnel temperature increasing significantly in summer and decreasing significantly in winter, with a small decrease in the average annual temperature. This study provides a theoretical reference for environment-based subway tunnel construction and the comprehensive utilization of tunnel waste heat.