Background: Intracranial arteriovenous malformations (AVMs) are lesions containing complex vessels with a lack of buffering capillary architecture which might result in hemorrhagic cerebrovascular accidents (CVAs). Intraoperative navigation can improve resection rates and functional preservation in patients with lesions in eloquent areas, but current systems have limitations that can distract the operator. Augmented Reality (AR) surgical technology can reduce these distractions and provide real-time information regarding vascular morphology and location. Methods: In this case report, an adult patient was admitted to the emergency department after a fall, and diagnostic imaging revealed a Spetzler–Martin grade I AVM in the right parietal region with evidence of rupture. The patient underwent a stereotactic microsurgical resection with assistance from augmented reality technology, which allowed for a hologram of the angioarchitecture to be projected onto the cortical surface, aiding in the recognition of the angiographic anatomy during surgery. Results: The patient’s postoperative recovery went smoothly. At 6-month follow-up, the patient had remained in stable condition, experiencing complete relief from his previous symptoms. The follow-up examination also revealed complete obliteration of the AVMs without any remaining pathological vascular structure. Conclusions: AR-assisted microsurgery makes both the dissection and resection steps safer and more delicate. As several innovations are occurring in AR technology today, it is likely that this novel technique will be increasingly adopted in both surgical applications and education. Although certain limitations exist, this technique may still become more efficient and precise as this novel technology its continues to develop further.
Background and Objectives: Recent advancements in spinal navigation methodologies, particularly augmented reality (AR) techniques, have significantly enhanced the precision of spinal instrumentation procedures. This study aimed to evaluate the efficacy of AR-assisted navigation in spinal instrumentation surgery for thoracolumbar scoliosis. Materials and Methods: This retrospective observational study included 10 patients with thoracolumbar scoliosis who met specific inclusion criteria and were recruited at a single medical center. Two neurosurgeons and one neuroradiologist used the Gertzbein–Robbins scale (GRS) for radiological evaluation. Preoperative and postoperative Cobb angles were measured to assess the correction of scoliosis. Overall, 257 screws were placed using the AR-assisted navigation system during thoracic and lumbar spinal deformity surgeries. Results: Among the 257 screws, 197 were placed in the thoracic spine and 60 in the lumbar spine, achieving an overall instrumentation accuracy of 98%. The preoperative Cobb angle of 69.5 ± 22.2° significantly improved to 10.1 ± 4.1° postoperatively. Regarding first-attempt screw placement accuracy, 97.4% of the screws in the thoracic spine (graded as GRS A or B) and 100% in the lumbar spine were placed with precision. Five grade C thoracic screws were identified, one of which required re-instrumentation. Conclusions: The AR navigation technique substantially improved the precision of spinal deformity surgery, with a high screw placement accuracy rate and significant scoliosis correction. The benefits of reduced attention diversion and an intuitive surgical experience suggest that AR technology could significantly improve spinal surgery practices and training programs, indicating potential for broader applicability in the future.
The coexistence of glioblastoma multiforme (GBM) and arteriovenous malformation (AVM) is rarely reported in the literature. According to the present literature, these GBM or glioma-related vascular malformations may present simultaneously in distinct regions of the brain or occur in the same area but at different times. So far, these distinct hypervascular glioblastomas have been described but are not classified as a separate pathological entities. Considering their heterogeneity and complexity, all the above mentioned cases remain challenging in diagnosis and therapeutic modality. Likewise, there is a paucity of data surrounding the simultaneous presentation of GBM with intracranial aneurysms. In the literature, the independent concurrence of these three intracranial lesions has never been reported. In this article, we present a case who suffered from intermittent headaches and dizziness initially and further radiographic examination revealed an internal carotid artery (ICA) aneurysm that occurred in the patient with coexisting GBM and AVM. Surgical intervention for tumor and AVM removal was performed smoothly. This patient underwent endovascular coiling for the ICA aneurysm 4 months postoperatively. In addition, we also review the current literature relating to this rare combination of medical conditions.
Despite advancement in surgical innovation, C1-C2 fixation remains challenging due to risks of screw malposition and vertebral artery (VA) injuries. Traditional image-based navigation, while useful, often demands that surgeons frequently shift their attention to external monitors, potentially causing distractions. In this article, we introduce a microscope-based augmented reality (AR) navigation system that projects both anatomical information and real-time navigation images directly onto the surgical field. In the present case report, we discuss a 37-year-old female who suffered from os odontoideum with C1-C2 subluxation. Employing AR-assisted navigation, the patient underwent the successful posterior instrumentation of C1-C2. The integrated AR system offers direct visualization, potentially minimizing surgical distractions. In our opinion, as AR technology advances, its adoption in surgical practices and education is anticipated to expand.
Background: This study evaluates the impact of hybrid dynamic stabilization using the Dynesys-Transition-Optima (DTO) system on adjacent segment disease (ASD) in lumbar spinal stenosis patients with spondylolisthesis. Methods: From 2012 to 2020, 115 patients underwent DTO stabilization at a single center by a single neurosurgeon. After exclusions for lack of specific stabilization and incomplete data, 31 patients were analyzed. Follow-up was conducted at 6, 12, and 24 months postoperatively, assessing disc height, listhesis distance, and angular motion changes at L2–L3, L3–L4, and L5–S1. Results: L3–L4 segment (the index level), demonstrated a delayed increase in listhesis distance, contrasting with earlier changes in other segments. At two years, L3–L4 exhibited less increase in listhesis distance and less disc height reduction compared to L2–L3 and L5–S1. Notably, the L3–L4 segment showed a significant reduction in angular motion change over two years. Conclusions: In conclusion, while ASD was not significantly prevented, the study indicates minor and delayed degeneration at the index level. The L3–L4 segment experienced reduced angular change in motion, suggesting a potential benefit of DTO in stabilizing this specific segment.