Bilal BOUDJELLAL

Dr. Bilal BOUDJELLAL

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2020 in Modelling, Measurement and Control A
Verified
Journal Article
Closed access
BBBilal BOUDJELLAL
Bilal BOUDJELLAL
TBTarak Benslimane
Tarak Benslimane
The purpose of this study is to improve the control performance of a Doubly Fed Induction Generator (DFIG) in a Wind Energy Conversion System (WECS) by using both of the conventional Proportional-Integral (PI) controllers and an Artificial Neural Network (ANN) based controllers. The rotor-side converter (RSC) voltages are controlled using a stator flux oriented control (FOC) to achieve an independent control of the active and reactive powers, exchanged between the stator of the DFIG and the power grid. Afterward, the PI controllers of the FOC are replaced with two ANN based controllers. A Maximum Power Point Tracking (MPPT) control strategy is necessary in order to extract the maximum power from the of wind energy system. A simulation model was carried out in MATLAB environment under different scenarios. The obtained results demonstrate the efficiency of the proposed ANN control strategy.

1 December 2016 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
BBBilal BOUDJELLAL
Bilal BOUDJELLAL
TBTarak Benslimane
Tarak Benslimane
This paper presents the study of an open switch fault tolerant control of a grid-connected photovoltaic system. The studied system is based on the classical DC–DC boost converter and a bidirectional 6-pulse DC–AC converter. The objective is to provide an open-switch fault detection method and fault-tolerant control for both of boost converter and grid-side converter (GSC) in a grid-connected photovoltaic system. A fast fault detection method and a reliable fault-tolerant topology are required to ensure continuity of service, and achieve a faster corrective maintenance. In this work, the mean value of the error voltages is used as fault indicator for the GSC, while, for the boost converter the inductor current form is used as fault indicator. The fault-tolerant topology was achieved by adding one redundant switch to the boost converter, and by adding one redundant leg to the GSC. The results of the fault tolerant control are presented and discussed to validate the proposed approach under different scenarios and different solar irradiances.